Wear resistance of isosit and polymethyl methacrylate occlusal splint material

J. K. Schulte, G. C. Anderson, Ronald Sakaguchi, R. DeLong

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Simulated occlusal wear utilizing the artifical mouth included natural enamel against isosit and polymethyl methacrylate splint materials. The results reported in volume loss (mm3) demonstrated the isosit material to be 55-67% more resistant to wear than polymethyl methacrylate. No wear occurred on the enamel surface opposing either splint material.

Original languageEnglish (US)
Pages (from-to)82-84
Number of pages3
JournalDental Materials
Volume3
Issue number2
DOIs
StatePublished - 1987
Externally publishedYes

Fingerprint

Occlusal Splints
Splints
Polymethyl Methacrylate
Dental Enamel
Polymethyl methacrylates
Wear resistance
Tooth Attrition
Enamels
Wear of materials
Mouth
Isosit

Keywords

  • artificial mouth
  • isosit splint material
  • occlusal splints
  • polymethyl methacrylate splint material
  • wear

ASJC Scopus subject areas

  • Mechanics of Materials
  • Materials Science(all)
  • Dentistry(all)

Cite this

Wear resistance of isosit and polymethyl methacrylate occlusal splint material. / Schulte, J. K.; Anderson, G. C.; Sakaguchi, Ronald; DeLong, R.

In: Dental Materials, Vol. 3, No. 2, 1987, p. 82-84.

Research output: Contribution to journalArticle

Schulte, J. K. ; Anderson, G. C. ; Sakaguchi, Ronald ; DeLong, R. / Wear resistance of isosit and polymethyl methacrylate occlusal splint material. In: Dental Materials. 1987 ; Vol. 3, No. 2. pp. 82-84.
@article{6d4eda42759c44cd95361040ce24fd5c,
title = "Wear resistance of isosit and polymethyl methacrylate occlusal splint material",
abstract = "Simulated occlusal wear utilizing the artifical mouth included natural enamel against isosit and polymethyl methacrylate splint materials. The results reported in volume loss (mm3) demonstrated the isosit material to be 55-67{\%} more resistant to wear than polymethyl methacrylate. No wear occurred on the enamel surface opposing either splint material.",
keywords = "artificial mouth, isosit splint material, occlusal splints, polymethyl methacrylate splint material, wear",
author = "Schulte, {J. K.} and Anderson, {G. C.} and Ronald Sakaguchi and R. DeLong",
year = "1987",
doi = "10.1016/S0109-5641(87)80010-6",
language = "English (US)",
volume = "3",
pages = "82--84",
journal = "Dental Materials",
issn = "0109-5641",
publisher = "Elsevier Science",
number = "2",

}

TY - JOUR

T1 - Wear resistance of isosit and polymethyl methacrylate occlusal splint material

AU - Schulte, J. K.

AU - Anderson, G. C.

AU - Sakaguchi, Ronald

AU - DeLong, R.

PY - 1987

Y1 - 1987

N2 - Simulated occlusal wear utilizing the artifical mouth included natural enamel against isosit and polymethyl methacrylate splint materials. The results reported in volume loss (mm3) demonstrated the isosit material to be 55-67% more resistant to wear than polymethyl methacrylate. No wear occurred on the enamel surface opposing either splint material.

AB - Simulated occlusal wear utilizing the artifical mouth included natural enamel against isosit and polymethyl methacrylate splint materials. The results reported in volume loss (mm3) demonstrated the isosit material to be 55-67% more resistant to wear than polymethyl methacrylate. No wear occurred on the enamel surface opposing either splint material.

KW - artificial mouth

KW - isosit splint material

KW - occlusal splints

KW - polymethyl methacrylate splint material

KW - wear

UR - http://www.scopus.com/inward/record.url?scp=0023316287&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023316287&partnerID=8YFLogxK

U2 - 10.1016/S0109-5641(87)80010-6

DO - 10.1016/S0109-5641(87)80010-6

M3 - Article

C2 - 3481583

AN - SCOPUS:0023316287

VL - 3

SP - 82

EP - 84

JO - Dental Materials

JF - Dental Materials

SN - 0109-5641

IS - 2

ER -