Wear and marginal breakdown of composites with various degrees of cure

Jack Ferracane, J. C. Mitchem, J. R. Condon, R. Todd

Research output: Contribution to journalArticle

281 Citations (Scopus)

Abstract

Loss of anatomical form due to wear has been cited as one factor limiting the clinical use of posterior composites. The physical properties and possibly the wear resistance of composite are influenced by the extent to which it is cured. The aim of this study was to vary degree of conversion (DC) in composites to test the hypothesis that resistance to wear and marginal breakdown could be improved by enhanced curing. A light-cured hybrid composite containing a 50% Bis-GMA/50% TEGDMA resin and 62 vol% of strontium glass (1 to 2 μm) with microfill silica was formulated (Bisco). Composite was placed into two 2.5-mm-diameter cylindrical holes in Co-Cr teeth replacing first and second molars in the mandibular dentures of 50 edentulous patients. The composites were light-cured for different time periods (9 s, 12 s, 25 s, 40 s, and 40 s + 10 min at 120°C) and then polished. The microfill Heliomolar was also tested. DC (%) was measured by FTIR and ranged between 55% for 9 s of light-curing and 67% for 40 s of light-curing followed by heat application. Impressions were evaluated at baseline, 6 mo, 1 yr, and 2 yrs. Stone casts were evaluated independently by three observers to determine the % of the total margin exhibiting breakdown. Epoxy replicas were measured with a profilometer for wear. Wear of the hybrid composite at 2 yrs ranged from a high of 144 μm with 9 s of light-curing to a low of 36 7mu;m with 40 s of light-curing followed by heat. Heliomolar exhibited from 11 to 16 pm of wear at 2 yrs. There was a strong negative correlation (r2 = 0.91) between the degree of cure and the abrasive wear of the hybrid composites. Marginal breakdown was negligible for the hybrids, and was reduced for the microfill from 40% to 15% of the margin by heat treatment. This study showed that the resistance to abrasive wear of a dental composite could be improved by enhancement of its degree of conversion.

Original languageEnglish (US)
Pages (from-to)1508-1516
Number of pages9
JournalJournal of Dental Research
Volume76
Issue number8
StatePublished - Aug 1997

Fingerprint

Light
Hot Temperature
Bisphenol A-Glycidyl Methacrylate
Tooth Wear
Strontium
Dentures
Fourier Transform Infrared Spectroscopy
Silicon Dioxide
Glass
Tooth
Heliomolar
Therapeutics

Keywords

  • Clinical
  • Composite
  • Degree of cure
  • Marginal fracture
  • Wear

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Ferracane, J., Mitchem, J. C., Condon, J. R., & Todd, R. (1997). Wear and marginal breakdown of composites with various degrees of cure. Journal of Dental Research, 76(8), 1508-1516.

Wear and marginal breakdown of composites with various degrees of cure. / Ferracane, Jack; Mitchem, J. C.; Condon, J. R.; Todd, R.

In: Journal of Dental Research, Vol. 76, No. 8, 08.1997, p. 1508-1516.

Research output: Contribution to journalArticle

Ferracane, J, Mitchem, JC, Condon, JR & Todd, R 1997, 'Wear and marginal breakdown of composites with various degrees of cure', Journal of Dental Research, vol. 76, no. 8, pp. 1508-1516.
Ferracane, Jack ; Mitchem, J. C. ; Condon, J. R. ; Todd, R. / Wear and marginal breakdown of composites with various degrees of cure. In: Journal of Dental Research. 1997 ; Vol. 76, No. 8. pp. 1508-1516.
@article{433adfd7613b4baf9104f1be3f94fd23,
title = "Wear and marginal breakdown of composites with various degrees of cure",
abstract = "Loss of anatomical form due to wear has been cited as one factor limiting the clinical use of posterior composites. The physical properties and possibly the wear resistance of composite are influenced by the extent to which it is cured. The aim of this study was to vary degree of conversion (DC) in composites to test the hypothesis that resistance to wear and marginal breakdown could be improved by enhanced curing. A light-cured hybrid composite containing a 50{\%} Bis-GMA/50{\%} TEGDMA resin and 62 vol{\%} of strontium glass (1 to 2 μm) with microfill silica was formulated (Bisco). Composite was placed into two 2.5-mm-diameter cylindrical holes in Co-Cr teeth replacing first and second molars in the mandibular dentures of 50 edentulous patients. The composites were light-cured for different time periods (9 s, 12 s, 25 s, 40 s, and 40 s + 10 min at 120°C) and then polished. The microfill Heliomolar was also tested. DC ({\%}) was measured by FTIR and ranged between 55{\%} for 9 s of light-curing and 67{\%} for 40 s of light-curing followed by heat application. Impressions were evaluated at baseline, 6 mo, 1 yr, and 2 yrs. Stone casts were evaluated independently by three observers to determine the {\%} of the total margin exhibiting breakdown. Epoxy replicas were measured with a profilometer for wear. Wear of the hybrid composite at 2 yrs ranged from a high of 144 μm with 9 s of light-curing to a low of 36 7mu;m with 40 s of light-curing followed by heat. Heliomolar exhibited from 11 to 16 pm of wear at 2 yrs. There was a strong negative correlation (r2 = 0.91) between the degree of cure and the abrasive wear of the hybrid composites. Marginal breakdown was negligible for the hybrids, and was reduced for the microfill from 40{\%} to 15{\%} of the margin by heat treatment. This study showed that the resistance to abrasive wear of a dental composite could be improved by enhancement of its degree of conversion.",
keywords = "Clinical, Composite, Degree of cure, Marginal fracture, Wear",
author = "Jack Ferracane and Mitchem, {J. C.} and Condon, {J. R.} and R. Todd",
year = "1997",
month = "8",
language = "English (US)",
volume = "76",
pages = "1508--1516",
journal = "Journal of Dental Research",
issn = "0022-0345",
publisher = "SAGE Publications Inc.",
number = "8",

}

TY - JOUR

T1 - Wear and marginal breakdown of composites with various degrees of cure

AU - Ferracane, Jack

AU - Mitchem, J. C.

AU - Condon, J. R.

AU - Todd, R.

PY - 1997/8

Y1 - 1997/8

N2 - Loss of anatomical form due to wear has been cited as one factor limiting the clinical use of posterior composites. The physical properties and possibly the wear resistance of composite are influenced by the extent to which it is cured. The aim of this study was to vary degree of conversion (DC) in composites to test the hypothesis that resistance to wear and marginal breakdown could be improved by enhanced curing. A light-cured hybrid composite containing a 50% Bis-GMA/50% TEGDMA resin and 62 vol% of strontium glass (1 to 2 μm) with microfill silica was formulated (Bisco). Composite was placed into two 2.5-mm-diameter cylindrical holes in Co-Cr teeth replacing first and second molars in the mandibular dentures of 50 edentulous patients. The composites were light-cured for different time periods (9 s, 12 s, 25 s, 40 s, and 40 s + 10 min at 120°C) and then polished. The microfill Heliomolar was also tested. DC (%) was measured by FTIR and ranged between 55% for 9 s of light-curing and 67% for 40 s of light-curing followed by heat application. Impressions were evaluated at baseline, 6 mo, 1 yr, and 2 yrs. Stone casts were evaluated independently by three observers to determine the % of the total margin exhibiting breakdown. Epoxy replicas were measured with a profilometer for wear. Wear of the hybrid composite at 2 yrs ranged from a high of 144 μm with 9 s of light-curing to a low of 36 7mu;m with 40 s of light-curing followed by heat. Heliomolar exhibited from 11 to 16 pm of wear at 2 yrs. There was a strong negative correlation (r2 = 0.91) between the degree of cure and the abrasive wear of the hybrid composites. Marginal breakdown was negligible for the hybrids, and was reduced for the microfill from 40% to 15% of the margin by heat treatment. This study showed that the resistance to abrasive wear of a dental composite could be improved by enhancement of its degree of conversion.

AB - Loss of anatomical form due to wear has been cited as one factor limiting the clinical use of posterior composites. The physical properties and possibly the wear resistance of composite are influenced by the extent to which it is cured. The aim of this study was to vary degree of conversion (DC) in composites to test the hypothesis that resistance to wear and marginal breakdown could be improved by enhanced curing. A light-cured hybrid composite containing a 50% Bis-GMA/50% TEGDMA resin and 62 vol% of strontium glass (1 to 2 μm) with microfill silica was formulated (Bisco). Composite was placed into two 2.5-mm-diameter cylindrical holes in Co-Cr teeth replacing first and second molars in the mandibular dentures of 50 edentulous patients. The composites were light-cured for different time periods (9 s, 12 s, 25 s, 40 s, and 40 s + 10 min at 120°C) and then polished. The microfill Heliomolar was also tested. DC (%) was measured by FTIR and ranged between 55% for 9 s of light-curing and 67% for 40 s of light-curing followed by heat application. Impressions were evaluated at baseline, 6 mo, 1 yr, and 2 yrs. Stone casts were evaluated independently by three observers to determine the % of the total margin exhibiting breakdown. Epoxy replicas were measured with a profilometer for wear. Wear of the hybrid composite at 2 yrs ranged from a high of 144 μm with 9 s of light-curing to a low of 36 7mu;m with 40 s of light-curing followed by heat. Heliomolar exhibited from 11 to 16 pm of wear at 2 yrs. There was a strong negative correlation (r2 = 0.91) between the degree of cure and the abrasive wear of the hybrid composites. Marginal breakdown was negligible for the hybrids, and was reduced for the microfill from 40% to 15% of the margin by heat treatment. This study showed that the resistance to abrasive wear of a dental composite could be improved by enhancement of its degree of conversion.

KW - Clinical

KW - Composite

KW - Degree of cure

KW - Marginal fracture

KW - Wear

UR - http://www.scopus.com/inward/record.url?scp=0031203673&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031203673&partnerID=8YFLogxK

M3 - Article

VL - 76

SP - 1508

EP - 1516

JO - Journal of Dental Research

JF - Journal of Dental Research

SN - 0022-0345

IS - 8

ER -