The need for structural allograft biomechanical guidelines

Satoshi Kawaguchi, Robert A. Hart

Research output: Contribution to journalReview article

Abstract

Because of their osteoconductive properties, structural bone allografts retain a theoretic advantage in biologic performance compared with artificial interbody fusion devices and endoprostheses. Present regulations have addressed the risks of disease transmission and tissue contamination, but comparatively few guidelines exist regarding donor eligibility and bone processing issues with a potential effect on the mechanical integrity of structural allograft bone. The lack of guidelines appears to have led to variation among allograft providers in terms of processing and donor screening regarding issues with recognized mechanical effects. Given the relative lack of data on which to base reasonable screening standards, we undertook basic biomechanical evaluation of one source of structural bone allograft, the femoral ring. Of our tested parameters, the minimum and maximum cortical wall thicknesses of femoral ring allograft were most strongly correlated with the axial compressive load to failure of the graft, suggesting that cortical wall thickness may be a useful screening tool for compressive resistance expected from fresh cortical bone allograft. Development of further biomechanical and clinical data to direct standard development appears warranted.

Original languageEnglish (US)
Pages (from-to)119-125
Number of pages7
JournalThe Journal of the American Academy of Orthopaedic Surgeons
Volume23
Issue number2
DOIs
StatePublished - Feb 1 2015
Externally publishedYes

Fingerprint

Allografts
Guidelines
Bone and Bones
Thigh
Donor Selection
Transplants
Equipment and Supplies

ASJC Scopus subject areas

  • Surgery
  • Orthopedics and Sports Medicine

Cite this

The need for structural allograft biomechanical guidelines. / Kawaguchi, Satoshi; Hart, Robert A.

In: The Journal of the American Academy of Orthopaedic Surgeons, Vol. 23, No. 2, 01.02.2015, p. 119-125.

Research output: Contribution to journalReview article

Kawaguchi, Satoshi ; Hart, Robert A. / The need for structural allograft biomechanical guidelines. In: The Journal of the American Academy of Orthopaedic Surgeons. 2015 ; Vol. 23, No. 2. pp. 119-125.
@article{e99f34ba937e4df997cb0564481f43ec,
title = "The need for structural allograft biomechanical guidelines",
abstract = "Because of their osteoconductive properties, structural bone allografts retain a theoretic advantage in biologic performance compared with artificial interbody fusion devices and endoprostheses. Present regulations have addressed the risks of disease transmission and tissue contamination, but comparatively few guidelines exist regarding donor eligibility and bone processing issues with a potential effect on the mechanical integrity of structural allograft bone. The lack of guidelines appears to have led to variation among allograft providers in terms of processing and donor screening regarding issues with recognized mechanical effects. Given the relative lack of data on which to base reasonable screening standards, we undertook basic biomechanical evaluation of one source of structural bone allograft, the femoral ring. Of our tested parameters, the minimum and maximum cortical wall thicknesses of femoral ring allograft were most strongly correlated with the axial compressive load to failure of the graft, suggesting that cortical wall thickness may be a useful screening tool for compressive resistance expected from fresh cortical bone allograft. Development of further biomechanical and clinical data to direct standard development appears warranted.",
author = "Satoshi Kawaguchi and Hart, {Robert A.}",
year = "2015",
month = "2",
day = "1",
doi = "10.5435/JAAOS-D-14-00263",
language = "English (US)",
volume = "23",
pages = "119--125",
journal = "Journal of the American Academy of Orthopaedic Surgeons",
issn = "1067-151X",
publisher = "American Association of Orthopaedic Surgeons",
number = "2",

}

TY - JOUR

T1 - The need for structural allograft biomechanical guidelines

AU - Kawaguchi, Satoshi

AU - Hart, Robert A.

PY - 2015/2/1

Y1 - 2015/2/1

N2 - Because of their osteoconductive properties, structural bone allografts retain a theoretic advantage in biologic performance compared with artificial interbody fusion devices and endoprostheses. Present regulations have addressed the risks of disease transmission and tissue contamination, but comparatively few guidelines exist regarding donor eligibility and bone processing issues with a potential effect on the mechanical integrity of structural allograft bone. The lack of guidelines appears to have led to variation among allograft providers in terms of processing and donor screening regarding issues with recognized mechanical effects. Given the relative lack of data on which to base reasonable screening standards, we undertook basic biomechanical evaluation of one source of structural bone allograft, the femoral ring. Of our tested parameters, the minimum and maximum cortical wall thicknesses of femoral ring allograft were most strongly correlated with the axial compressive load to failure of the graft, suggesting that cortical wall thickness may be a useful screening tool for compressive resistance expected from fresh cortical bone allograft. Development of further biomechanical and clinical data to direct standard development appears warranted.

AB - Because of their osteoconductive properties, structural bone allografts retain a theoretic advantage in biologic performance compared with artificial interbody fusion devices and endoprostheses. Present regulations have addressed the risks of disease transmission and tissue contamination, but comparatively few guidelines exist regarding donor eligibility and bone processing issues with a potential effect on the mechanical integrity of structural allograft bone. The lack of guidelines appears to have led to variation among allograft providers in terms of processing and donor screening regarding issues with recognized mechanical effects. Given the relative lack of data on which to base reasonable screening standards, we undertook basic biomechanical evaluation of one source of structural bone allograft, the femoral ring. Of our tested parameters, the minimum and maximum cortical wall thicknesses of femoral ring allograft were most strongly correlated with the axial compressive load to failure of the graft, suggesting that cortical wall thickness may be a useful screening tool for compressive resistance expected from fresh cortical bone allograft. Development of further biomechanical and clinical data to direct standard development appears warranted.

UR - http://www.scopus.com/inward/record.url?scp=84941735926&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84941735926&partnerID=8YFLogxK

U2 - 10.5435/JAAOS-D-14-00263

DO - 10.5435/JAAOS-D-14-00263

M3 - Review article

C2 - 25624364

VL - 23

SP - 119

EP - 125

JO - Journal of the American Academy of Orthopaedic Surgeons

JF - Journal of the American Academy of Orthopaedic Surgeons

SN - 1067-151X

IS - 2

ER -