Abstract

We report a single pass gas phase route to [11C]CHI based on production of I· from I2 at elevated temperature. I· abstracts H from CH4 to yield ·CH3, which reacts with I2 to form CH3I. A fiber optic spectrometer was used to measure the I2 vapor concentration. [11C]CH3I yield increased with I2 concentration until excessive amounts of condensed I2 began to trap the 11C. The yield of [11C]CH3I was >50% from [11C]CH4; its specific activity was 12,000 Ci/mmole. The synthesis takes only 4 min after 11CH4 production and can be repeated without system cleanup.

Original languageEnglish (US)
Pages (from-to)93-97
Number of pages5
JournalNuclear Medicine and Biology
Volume24
Issue number1
DOIs
StatePublished - Jan 1997
Externally publishedYes

Fingerprint

Myelinated Nerve Fibers
Gases
Temperature

Keywords

  • fiber optic spectrometer
  • meta-hydroxyephedrine
  • methyl iodide
  • specific activity measurement for C

ASJC Scopus subject areas

  • Cancer Research
  • Molecular Medicine
  • Radiology Nuclear Medicine and imaging

Cite this

Production of [11C]CH3I by single pass reaction of [11C]CH4 with I2. / Link, Jeanne; Krohn, Kenneth; Clark, John C.

In: Nuclear Medicine and Biology, Vol. 24, No. 1, 01.1997, p. 93-97.

Research output: Contribution to journalArticle

@article{3d8f241c18794f50bcb40876670bcea8,
title = "Production of [11C]CH3I by single pass reaction of [11C]CH4 with I2",
abstract = "We report a single pass gas phase route to [11C]CHI based on production of I· from I2 at elevated temperature. I· abstracts H from CH4 to yield ·CH3, which reacts with I2 to form CH3I. A fiber optic spectrometer was used to measure the I2 vapor concentration. [11C]CH3I yield increased with I2 concentration until excessive amounts of condensed I2 began to trap the 11C. The yield of [11C]CH3I was >50{\%} from [11C]CH4; its specific activity was 12,000 Ci/mmole. The synthesis takes only 4 min after 11CH4 production and can be repeated without system cleanup.",
keywords = "fiber optic spectrometer, meta-hydroxyephedrine, methyl iodide, specific activity measurement for C",
author = "Jeanne Link and Kenneth Krohn and Clark, {John C.}",
year = "1997",
month = "1",
doi = "10.1016/S0969-8051(96)00181-3",
language = "English (US)",
volume = "24",
pages = "93--97",
journal = "International journal of radiation applications and instrumentation. Part B, Nuclear medicine and biology",
issn = "0969-8051",
publisher = "Elsevier Inc.",
number = "1",

}

TY - JOUR

T1 - Production of [11C]CH3I by single pass reaction of [11C]CH4 with I2

AU - Link, Jeanne

AU - Krohn, Kenneth

AU - Clark, John C.

PY - 1997/1

Y1 - 1997/1

N2 - We report a single pass gas phase route to [11C]CHI based on production of I· from I2 at elevated temperature. I· abstracts H from CH4 to yield ·CH3, which reacts with I2 to form CH3I. A fiber optic spectrometer was used to measure the I2 vapor concentration. [11C]CH3I yield increased with I2 concentration until excessive amounts of condensed I2 began to trap the 11C. The yield of [11C]CH3I was >50% from [11C]CH4; its specific activity was 12,000 Ci/mmole. The synthesis takes only 4 min after 11CH4 production and can be repeated without system cleanup.

AB - We report a single pass gas phase route to [11C]CHI based on production of I· from I2 at elevated temperature. I· abstracts H from CH4 to yield ·CH3, which reacts with I2 to form CH3I. A fiber optic spectrometer was used to measure the I2 vapor concentration. [11C]CH3I yield increased with I2 concentration until excessive amounts of condensed I2 began to trap the 11C. The yield of [11C]CH3I was >50% from [11C]CH4; its specific activity was 12,000 Ci/mmole. The synthesis takes only 4 min after 11CH4 production and can be repeated without system cleanup.

KW - fiber optic spectrometer

KW - meta-hydroxyephedrine

KW - methyl iodide

KW - specific activity measurement for C

UR - http://www.scopus.com/inward/record.url?scp=0030609886&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030609886&partnerID=8YFLogxK

U2 - 10.1016/S0969-8051(96)00181-3

DO - 10.1016/S0969-8051(96)00181-3

M3 - Article

VL - 24

SP - 93

EP - 97

JO - International journal of radiation applications and instrumentation. Part B, Nuclear medicine and biology

JF - International journal of radiation applications and instrumentation. Part B, Nuclear medicine and biology

SN - 0969-8051

IS - 1

ER -