Precurving of nickel-titanium files affects transportation in simulated canals

Timothy Svec, M. Micheal Wang

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Instrumentation studies comparing nickel-titanium with stainless-steel files have been performed without precurving the nickel-titanium files. It is unknown what influence the precurving of nickel-titanium files would have on transportation in small curved canals of varying curvatures. One hundred-sixty resin blocks with simulated canals were used. Eighty blocks had gradual (gradual curve (GC)) 30-degree curves; the remainder had abrupt (abrupt curve (AC)) 30-degree curves. Ten blocks for each curvature and for each degree of precurving (0,15, 20, 25,30, 35,40, and 45) were instrumented with a machine that imparted only an in and out motion. Simulated canals were a size 30 at the apex, and size 30 nickel-titanium files were used to instrument the canals. A transportation "t" index was determined at two levels: T1 (1 mm from the apex) and TB (a line bisecting the curve of the canal). For GC at T1 and TB, 45- and 25-degree curved instruments, respectively, produced significantly less transportation (p <0.0001). For AC at T1 and TB, 35- and 0-degree curved instruments, respectively, produced significantly less transportation (p <0.0001). Comparing GC and AC, the transportation for GC was significantly less (p <0.0015).

Original languageEnglish (US)
Pages (from-to)23-25
Number of pages3
JournalJournal of Endodontics
Volume24
Issue number1
StatePublished - 1998
Externally publishedYes

Fingerprint

Stainless Steel
nitinol

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Precurving of nickel-titanium files affects transportation in simulated canals. / Svec, Timothy; Wang, M. Micheal.

In: Journal of Endodontics, Vol. 24, No. 1, 1998, p. 23-25.

Research output: Contribution to journalArticle

Svec, Timothy ; Wang, M. Micheal. / Precurving of nickel-titanium files affects transportation in simulated canals. In: Journal of Endodontics. 1998 ; Vol. 24, No. 1. pp. 23-25.
@article{dd159b31d4b343a9a06bb3f741f8668f,
title = "Precurving of nickel-titanium files affects transportation in simulated canals",
abstract = "Instrumentation studies comparing nickel-titanium with stainless-steel files have been performed without precurving the nickel-titanium files. It is unknown what influence the precurving of nickel-titanium files would have on transportation in small curved canals of varying curvatures. One hundred-sixty resin blocks with simulated canals were used. Eighty blocks had gradual (gradual curve (GC)) 30-degree curves; the remainder had abrupt (abrupt curve (AC)) 30-degree curves. Ten blocks for each curvature and for each degree of precurving (0,15, 20, 25,30, 35,40, and 45) were instrumented with a machine that imparted only an in and out motion. Simulated canals were a size 30 at the apex, and size 30 nickel-titanium files were used to instrument the canals. A transportation {"}t{"} index was determined at two levels: T1 (1 mm from the apex) and TB (a line bisecting the curve of the canal). For GC at T1 and TB, 45- and 25-degree curved instruments, respectively, produced significantly less transportation (p <0.0001). For AC at T1 and TB, 35- and 0-degree curved instruments, respectively, produced significantly less transportation (p <0.0001). Comparing GC and AC, the transportation for GC was significantly less (p <0.0015).",
author = "Timothy Svec and Wang, {M. Micheal}",
year = "1998",
language = "English (US)",
volume = "24",
pages = "23--25",
journal = "Journal of Endodontics",
issn = "0099-2399",
publisher = "Elsevier Inc.",
number = "1",

}

TY - JOUR

T1 - Precurving of nickel-titanium files affects transportation in simulated canals

AU - Svec, Timothy

AU - Wang, M. Micheal

PY - 1998

Y1 - 1998

N2 - Instrumentation studies comparing nickel-titanium with stainless-steel files have been performed without precurving the nickel-titanium files. It is unknown what influence the precurving of nickel-titanium files would have on transportation in small curved canals of varying curvatures. One hundred-sixty resin blocks with simulated canals were used. Eighty blocks had gradual (gradual curve (GC)) 30-degree curves; the remainder had abrupt (abrupt curve (AC)) 30-degree curves. Ten blocks for each curvature and for each degree of precurving (0,15, 20, 25,30, 35,40, and 45) were instrumented with a machine that imparted only an in and out motion. Simulated canals were a size 30 at the apex, and size 30 nickel-titanium files were used to instrument the canals. A transportation "t" index was determined at two levels: T1 (1 mm from the apex) and TB (a line bisecting the curve of the canal). For GC at T1 and TB, 45- and 25-degree curved instruments, respectively, produced significantly less transportation (p <0.0001). For AC at T1 and TB, 35- and 0-degree curved instruments, respectively, produced significantly less transportation (p <0.0001). Comparing GC and AC, the transportation for GC was significantly less (p <0.0015).

AB - Instrumentation studies comparing nickel-titanium with stainless-steel files have been performed without precurving the nickel-titanium files. It is unknown what influence the precurving of nickel-titanium files would have on transportation in small curved canals of varying curvatures. One hundred-sixty resin blocks with simulated canals were used. Eighty blocks had gradual (gradual curve (GC)) 30-degree curves; the remainder had abrupt (abrupt curve (AC)) 30-degree curves. Ten blocks for each curvature and for each degree of precurving (0,15, 20, 25,30, 35,40, and 45) were instrumented with a machine that imparted only an in and out motion. Simulated canals were a size 30 at the apex, and size 30 nickel-titanium files were used to instrument the canals. A transportation "t" index was determined at two levels: T1 (1 mm from the apex) and TB (a line bisecting the curve of the canal). For GC at T1 and TB, 45- and 25-degree curved instruments, respectively, produced significantly less transportation (p <0.0001). For AC at T1 and TB, 35- and 0-degree curved instruments, respectively, produced significantly less transportation (p <0.0001). Comparing GC and AC, the transportation for GC was significantly less (p <0.0015).

UR - http://www.scopus.com/inward/record.url?scp=0031606383&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031606383&partnerID=8YFLogxK

M3 - Article

VL - 24

SP - 23

EP - 25

JO - Journal of Endodontics

JF - Journal of Endodontics

SN - 0099-2399

IS - 1

ER -