Myocardial T1 mapping with MRI

Comparison of look-locker and MOLLI sequences

Marcelo Souto Nacif, Evrim B. Turkbey, Neville Gai, Saman Nazarian, Rob J. Van Der Geest, Radwa A. Noureldin, Christopher Sibley, Martin Ugander, Songtao Liu, Andrew E. Arai, João A C Lima, David A. Bluemke

Research output: Contribution to journalArticle

77 Citations (Scopus)

Abstract

Purpose: To evaluate the relationship between "Look-Locker" (LL) and modified Look-Locker Inversion recovery (MOLLI) approaches for T1 mapping of the myocardium. Materials and Methods: A total of 168 myocardial T1 maps using MOLLI and 165 maps using LL were obtained in human subjects at 1.5 Tesla. The T1 values of the myocardium were calculated before and at five time points after gadolinium administration. All time and heart rate normalizations were done. The T1 values obtained were compared to determine the absolute and bias agreement. Results: The precontrast global T1 values were similar when measured by the LL and by MOLLI technique (mean, 1004.9 ms ± 120.3 versus 1034.1 ms ± 53.1, respectively, P = 0.26). Postcontrast myocardial T1 time from LL was significantly longer than MOLLI from 5 to 25 min (mean difference, LL - MOLLI was +61.8 ± 46.4 ms, P <0.001). No significant differences in T1 values were noted between long and short axis measurements for either MOLLI or LL. Conclusion: Postcontrast LL and MOLLI showed very good agreement, although LL values are higher than MOLLI. Precontrast T1 values showed good agreement, however LL has greater limits of agreement. Short and long axis planes can reliably assess T1 values.

Original languageEnglish (US)
Pages (from-to)1367-1373
Number of pages7
JournalJournal of Magnetic Resonance Imaging
Volume34
Issue number6
DOIs
StatePublished - Dec 2011
Externally publishedYes

Fingerprint

Sequence Inversion
Myocardium
Gadolinium
Heart Rate

Keywords

  • diffuse myocardium fibrosis
  • magnetic resonance imaging
  • T1 mapping

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Nacif, M. S., Turkbey, E. B., Gai, N., Nazarian, S., Van Der Geest, R. J., Noureldin, R. A., ... Bluemke, D. A. (2011). Myocardial T1 mapping with MRI: Comparison of look-locker and MOLLI sequences. Journal of Magnetic Resonance Imaging, 34(6), 1367-1373. https://doi.org/10.1002/jmri.22753

Myocardial T1 mapping with MRI : Comparison of look-locker and MOLLI sequences. / Nacif, Marcelo Souto; Turkbey, Evrim B.; Gai, Neville; Nazarian, Saman; Van Der Geest, Rob J.; Noureldin, Radwa A.; Sibley, Christopher; Ugander, Martin; Liu, Songtao; Arai, Andrew E.; Lima, João A C; Bluemke, David A.

In: Journal of Magnetic Resonance Imaging, Vol. 34, No. 6, 12.2011, p. 1367-1373.

Research output: Contribution to journalArticle

Nacif, MS, Turkbey, EB, Gai, N, Nazarian, S, Van Der Geest, RJ, Noureldin, RA, Sibley, C, Ugander, M, Liu, S, Arai, AE, Lima, JAC & Bluemke, DA 2011, 'Myocardial T1 mapping with MRI: Comparison of look-locker and MOLLI sequences', Journal of Magnetic Resonance Imaging, vol. 34, no. 6, pp. 1367-1373. https://doi.org/10.1002/jmri.22753
Nacif MS, Turkbey EB, Gai N, Nazarian S, Van Der Geest RJ, Noureldin RA et al. Myocardial T1 mapping with MRI: Comparison of look-locker and MOLLI sequences. Journal of Magnetic Resonance Imaging. 2011 Dec;34(6):1367-1373. https://doi.org/10.1002/jmri.22753
Nacif, Marcelo Souto ; Turkbey, Evrim B. ; Gai, Neville ; Nazarian, Saman ; Van Der Geest, Rob J. ; Noureldin, Radwa A. ; Sibley, Christopher ; Ugander, Martin ; Liu, Songtao ; Arai, Andrew E. ; Lima, João A C ; Bluemke, David A. / Myocardial T1 mapping with MRI : Comparison of look-locker and MOLLI sequences. In: Journal of Magnetic Resonance Imaging. 2011 ; Vol. 34, No. 6. pp. 1367-1373.
@article{bdf05d5dba4c4f7eabc232de26fd39f2,
title = "Myocardial T1 mapping with MRI: Comparison of look-locker and MOLLI sequences",
abstract = "Purpose: To evaluate the relationship between {"}Look-Locker{"} (LL) and modified Look-Locker Inversion recovery (MOLLI) approaches for T1 mapping of the myocardium. Materials and Methods: A total of 168 myocardial T1 maps using MOLLI and 165 maps using LL were obtained in human subjects at 1.5 Tesla. The T1 values of the myocardium were calculated before and at five time points after gadolinium administration. All time and heart rate normalizations were done. The T1 values obtained were compared to determine the absolute and bias agreement. Results: The precontrast global T1 values were similar when measured by the LL and by MOLLI technique (mean, 1004.9 ms ± 120.3 versus 1034.1 ms ± 53.1, respectively, P = 0.26). Postcontrast myocardial T1 time from LL was significantly longer than MOLLI from 5 to 25 min (mean difference, LL - MOLLI was +61.8 ± 46.4 ms, P <0.001). No significant differences in T1 values were noted between long and short axis measurements for either MOLLI or LL. Conclusion: Postcontrast LL and MOLLI showed very good agreement, although LL values are higher than MOLLI. Precontrast T1 values showed good agreement, however LL has greater limits of agreement. Short and long axis planes can reliably assess T1 values.",
keywords = "diffuse myocardium fibrosis, magnetic resonance imaging, T1 mapping",
author = "Nacif, {Marcelo Souto} and Turkbey, {Evrim B.} and Neville Gai and Saman Nazarian and {Van Der Geest}, {Rob J.} and Noureldin, {Radwa A.} and Christopher Sibley and Martin Ugander and Songtao Liu and Arai, {Andrew E.} and Lima, {Jo{\~a}o A C} and Bluemke, {David A.}",
year = "2011",
month = "12",
doi = "10.1002/jmri.22753",
language = "English (US)",
volume = "34",
pages = "1367--1373",
journal = "Journal of Magnetic Resonance Imaging",
issn = "1053-1807",
publisher = "John Wiley and Sons Inc.",
number = "6",

}

TY - JOUR

T1 - Myocardial T1 mapping with MRI

T2 - Comparison of look-locker and MOLLI sequences

AU - Nacif, Marcelo Souto

AU - Turkbey, Evrim B.

AU - Gai, Neville

AU - Nazarian, Saman

AU - Van Der Geest, Rob J.

AU - Noureldin, Radwa A.

AU - Sibley, Christopher

AU - Ugander, Martin

AU - Liu, Songtao

AU - Arai, Andrew E.

AU - Lima, João A C

AU - Bluemke, David A.

PY - 2011/12

Y1 - 2011/12

N2 - Purpose: To evaluate the relationship between "Look-Locker" (LL) and modified Look-Locker Inversion recovery (MOLLI) approaches for T1 mapping of the myocardium. Materials and Methods: A total of 168 myocardial T1 maps using MOLLI and 165 maps using LL were obtained in human subjects at 1.5 Tesla. The T1 values of the myocardium were calculated before and at five time points after gadolinium administration. All time and heart rate normalizations were done. The T1 values obtained were compared to determine the absolute and bias agreement. Results: The precontrast global T1 values were similar when measured by the LL and by MOLLI technique (mean, 1004.9 ms ± 120.3 versus 1034.1 ms ± 53.1, respectively, P = 0.26). Postcontrast myocardial T1 time from LL was significantly longer than MOLLI from 5 to 25 min (mean difference, LL - MOLLI was +61.8 ± 46.4 ms, P <0.001). No significant differences in T1 values were noted between long and short axis measurements for either MOLLI or LL. Conclusion: Postcontrast LL and MOLLI showed very good agreement, although LL values are higher than MOLLI. Precontrast T1 values showed good agreement, however LL has greater limits of agreement. Short and long axis planes can reliably assess T1 values.

AB - Purpose: To evaluate the relationship between "Look-Locker" (LL) and modified Look-Locker Inversion recovery (MOLLI) approaches for T1 mapping of the myocardium. Materials and Methods: A total of 168 myocardial T1 maps using MOLLI and 165 maps using LL were obtained in human subjects at 1.5 Tesla. The T1 values of the myocardium were calculated before and at five time points after gadolinium administration. All time and heart rate normalizations were done. The T1 values obtained were compared to determine the absolute and bias agreement. Results: The precontrast global T1 values were similar when measured by the LL and by MOLLI technique (mean, 1004.9 ms ± 120.3 versus 1034.1 ms ± 53.1, respectively, P = 0.26). Postcontrast myocardial T1 time from LL was significantly longer than MOLLI from 5 to 25 min (mean difference, LL - MOLLI was +61.8 ± 46.4 ms, P <0.001). No significant differences in T1 values were noted between long and short axis measurements for either MOLLI or LL. Conclusion: Postcontrast LL and MOLLI showed very good agreement, although LL values are higher than MOLLI. Precontrast T1 values showed good agreement, however LL has greater limits of agreement. Short and long axis planes can reliably assess T1 values.

KW - diffuse myocardium fibrosis

KW - magnetic resonance imaging

KW - T1 mapping

UR - http://www.scopus.com/inward/record.url?scp=81755163105&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=81755163105&partnerID=8YFLogxK

U2 - 10.1002/jmri.22753

DO - 10.1002/jmri.22753

M3 - Article

VL - 34

SP - 1367

EP - 1373

JO - Journal of Magnetic Resonance Imaging

JF - Journal of Magnetic Resonance Imaging

SN - 1053-1807

IS - 6

ER -