Experimental studies to define the geometry of the flow convergence region: Laser Doppler particle tracking and color Doppler imaging

R. Shandas, M. Gharib, D. Liepmann, T. Shiota, David Sahn

Research output: Contribution to journalArticle

39 Citations (Scopus)

Abstract

The color flow convergence method for calculating volume flow through regurgitant or forward flow restrictive orifices has gained significant interest and a number of in vitro studies have suggested that this method is accurate, even in pulsatile models. Clinical application of the method over a wide range of conditions will require improved understanding of the effect of orifice size, flow geometry, and flow rate on the flow convergence geometry. In this study, we performed laser particle tracking investigations to allow visualization of streamlines into stenotic orifices. These streamlines are theoretically perpendicular to the isovelocity surfaces used for flow convergence calculations. We compared those observations to color flow map, flow convergence images obtained with a Toshiba 160A for orifices 5 to 15 mm2 with flow rates of 1.5 to 9.7 L/min. Our results show that for large orifices, low flow rates, and/or low pressure gradients, more oblique streamlines in the velocity of the orifice correspond to nonhemispherical, but more elliptical, flow convergence geometries. This can be corrected for by using lower Nyquist limits and calculating flow convergence at greater distances from the orifice. Under high flow and high gradient conditions, increased Nyquist limits and shorter aliasing radii are more suitable. Our studies yield insights into flow convergence geometry and yield corrective procedures to improve volume flow calculation.

Original languageEnglish (US)
Pages (from-to)43-50
Number of pages8
JournalEchocardiography
Volume9
Issue number1
StatePublished - 1992
Externally publishedYes

Fingerprint

Lasers
Color
Pressure

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Radiology Nuclear Medicine and imaging

Cite this

Experimental studies to define the geometry of the flow convergence region : Laser Doppler particle tracking and color Doppler imaging. / Shandas, R.; Gharib, M.; Liepmann, D.; Shiota, T.; Sahn, David.

In: Echocardiography, Vol. 9, No. 1, 1992, p. 43-50.

Research output: Contribution to journalArticle

Shandas, R. ; Gharib, M. ; Liepmann, D. ; Shiota, T. ; Sahn, David. / Experimental studies to define the geometry of the flow convergence region : Laser Doppler particle tracking and color Doppler imaging. In: Echocardiography. 1992 ; Vol. 9, No. 1. pp. 43-50.
@article{614f3a15cd584148a50fff948e1b08a1,
title = "Experimental studies to define the geometry of the flow convergence region: Laser Doppler particle tracking and color Doppler imaging",
abstract = "The color flow convergence method for calculating volume flow through regurgitant or forward flow restrictive orifices has gained significant interest and a number of in vitro studies have suggested that this method is accurate, even in pulsatile models. Clinical application of the method over a wide range of conditions will require improved understanding of the effect of orifice size, flow geometry, and flow rate on the flow convergence geometry. In this study, we performed laser particle tracking investigations to allow visualization of streamlines into stenotic orifices. These streamlines are theoretically perpendicular to the isovelocity surfaces used for flow convergence calculations. We compared those observations to color flow map, flow convergence images obtained with a Toshiba 160A for orifices 5 to 15 mm2 with flow rates of 1.5 to 9.7 L/min. Our results show that for large orifices, low flow rates, and/or low pressure gradients, more oblique streamlines in the velocity of the orifice correspond to nonhemispherical, but more elliptical, flow convergence geometries. This can be corrected for by using lower Nyquist limits and calculating flow convergence at greater distances from the orifice. Under high flow and high gradient conditions, increased Nyquist limits and shorter aliasing radii are more suitable. Our studies yield insights into flow convergence geometry and yield corrective procedures to improve volume flow calculation.",
author = "R. Shandas and M. Gharib and D. Liepmann and T. Shiota and David Sahn",
year = "1992",
language = "English (US)",
volume = "9",
pages = "43--50",
journal = "Echocardiography",
issn = "0742-2822",
publisher = "Wiley-Blackwell",
number = "1",

}

TY - JOUR

T1 - Experimental studies to define the geometry of the flow convergence region

T2 - Laser Doppler particle tracking and color Doppler imaging

AU - Shandas, R.

AU - Gharib, M.

AU - Liepmann, D.

AU - Shiota, T.

AU - Sahn, David

PY - 1992

Y1 - 1992

N2 - The color flow convergence method for calculating volume flow through regurgitant or forward flow restrictive orifices has gained significant interest and a number of in vitro studies have suggested that this method is accurate, even in pulsatile models. Clinical application of the method over a wide range of conditions will require improved understanding of the effect of orifice size, flow geometry, and flow rate on the flow convergence geometry. In this study, we performed laser particle tracking investigations to allow visualization of streamlines into stenotic orifices. These streamlines are theoretically perpendicular to the isovelocity surfaces used for flow convergence calculations. We compared those observations to color flow map, flow convergence images obtained with a Toshiba 160A for orifices 5 to 15 mm2 with flow rates of 1.5 to 9.7 L/min. Our results show that for large orifices, low flow rates, and/or low pressure gradients, more oblique streamlines in the velocity of the orifice correspond to nonhemispherical, but more elliptical, flow convergence geometries. This can be corrected for by using lower Nyquist limits and calculating flow convergence at greater distances from the orifice. Under high flow and high gradient conditions, increased Nyquist limits and shorter aliasing radii are more suitable. Our studies yield insights into flow convergence geometry and yield corrective procedures to improve volume flow calculation.

AB - The color flow convergence method for calculating volume flow through regurgitant or forward flow restrictive orifices has gained significant interest and a number of in vitro studies have suggested that this method is accurate, even in pulsatile models. Clinical application of the method over a wide range of conditions will require improved understanding of the effect of orifice size, flow geometry, and flow rate on the flow convergence geometry. In this study, we performed laser particle tracking investigations to allow visualization of streamlines into stenotic orifices. These streamlines are theoretically perpendicular to the isovelocity surfaces used for flow convergence calculations. We compared those observations to color flow map, flow convergence images obtained with a Toshiba 160A for orifices 5 to 15 mm2 with flow rates of 1.5 to 9.7 L/min. Our results show that for large orifices, low flow rates, and/or low pressure gradients, more oblique streamlines in the velocity of the orifice correspond to nonhemispherical, but more elliptical, flow convergence geometries. This can be corrected for by using lower Nyquist limits and calculating flow convergence at greater distances from the orifice. Under high flow and high gradient conditions, increased Nyquist limits and shorter aliasing radii are more suitable. Our studies yield insights into flow convergence geometry and yield corrective procedures to improve volume flow calculation.

UR - http://www.scopus.com/inward/record.url?scp=0026517257&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026517257&partnerID=8YFLogxK

M3 - Article

C2 - 10149869

AN - SCOPUS:0026517257

VL - 9

SP - 43

EP - 50

JO - Echocardiography

JF - Echocardiography

SN - 0742-2822

IS - 1

ER -