Electrokinetic device design and constraints for use in high conductance solutions

D. P. Heineck, J. M. Lewis, Michael (Mike) Heller

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

The quest for new cell-free DNA and exosome biomarker-based molecular diagnostics require fast and efficient sample preparation techniques. Conventional methods for isolating these biomarkers from blood are both time-consuming and laborious. New electrokinetic microarray devices using dielectrophoresis (DEP) to isolate cell-free DNA and exosome biomarkers have now greatly improved the sample preparation process. Nevertheless, these devices still have some limitations when used with high conductance biological fluids, e.g. blood, plasma, and serum. This study demonstrates that electrochemical damage may occur on the platinum electrodes of DEP microarray devices. It further examines two model device designs that include a parallel wire arrangement and a planar array. Effective isolation of fluorescent beads with parallel wires is shown under low-conductance conditions (10−4 S/m), but electrothermal flow overcomes DEP forces under high conductance conditions (>0.1 S/m). Planar devices are shown to be effective under high conductance conditions (∼1 S/m) without the deleterious effects of electrothermal flow. This study provides new insights into design compromises and limitations for producing future electrokinetic devices for better performance with high conductance solutions.

Original languageEnglish (US)
Pages (from-to)1475-1482
Number of pages8
JournalELECTROPHORESIS
Volume38
Issue number11
DOIs
StatePublished - Jun 1 2017
Externally publishedYes

Fingerprint

Equipment Design
Biomarkers
Electrophoresis
Microarrays
Equipment and Supplies
Exosomes
Blood
Wire
DNA
Platinum
Molecular Pathology
Plasmas
Electrodes
Fluids
Serum

Keywords

  • Blood
  • Cell-free DNA
  • Dielectrophoresis
  • Exosomes
  • Plasma

ASJC Scopus subject areas

  • Analytical Chemistry
  • Biochemistry
  • Clinical Biochemistry

Cite this

Electrokinetic device design and constraints for use in high conductance solutions. / Heineck, D. P.; Lewis, J. M.; Heller, Michael (Mike).

In: ELECTROPHORESIS, Vol. 38, No. 11, 01.06.2017, p. 1475-1482.

Research output: Contribution to journalArticle

@article{d884428becc4478cba898e6c5fea195c,
title = "Electrokinetic device design and constraints for use in high conductance solutions",
abstract = "The quest for new cell-free DNA and exosome biomarker-based molecular diagnostics require fast and efficient sample preparation techniques. Conventional methods for isolating these biomarkers from blood are both time-consuming and laborious. New electrokinetic microarray devices using dielectrophoresis (DEP) to isolate cell-free DNA and exosome biomarkers have now greatly improved the sample preparation process. Nevertheless, these devices still have some limitations when used with high conductance biological fluids, e.g. blood, plasma, and serum. This study demonstrates that electrochemical damage may occur on the platinum electrodes of DEP microarray devices. It further examines two model device designs that include a parallel wire arrangement and a planar array. Effective isolation of fluorescent beads with parallel wires is shown under low-conductance conditions (10−4 S/m), but electrothermal flow overcomes DEP forces under high conductance conditions (>0.1 S/m). Planar devices are shown to be effective under high conductance conditions (∼1 S/m) without the deleterious effects of electrothermal flow. This study provides new insights into design compromises and limitations for producing future electrokinetic devices for better performance with high conductance solutions.",
keywords = "Blood, Cell-free DNA, Dielectrophoresis, Exosomes, Plasma",
author = "Heineck, {D. P.} and Lewis, {J. M.} and Heller, {Michael (Mike)}",
year = "2017",
month = "6",
day = "1",
doi = "10.1002/elps.201600563",
language = "English (US)",
volume = "38",
pages = "1475--1482",
journal = "Electrophoresis",
issn = "0173-0835",
publisher = "Wiley-VCH Verlag",
number = "11",

}

TY - JOUR

T1 - Electrokinetic device design and constraints for use in high conductance solutions

AU - Heineck, D. P.

AU - Lewis, J. M.

AU - Heller, Michael (Mike)

PY - 2017/6/1

Y1 - 2017/6/1

N2 - The quest for new cell-free DNA and exosome biomarker-based molecular diagnostics require fast and efficient sample preparation techniques. Conventional methods for isolating these biomarkers from blood are both time-consuming and laborious. New electrokinetic microarray devices using dielectrophoresis (DEP) to isolate cell-free DNA and exosome biomarkers have now greatly improved the sample preparation process. Nevertheless, these devices still have some limitations when used with high conductance biological fluids, e.g. blood, plasma, and serum. This study demonstrates that electrochemical damage may occur on the platinum electrodes of DEP microarray devices. It further examines two model device designs that include a parallel wire arrangement and a planar array. Effective isolation of fluorescent beads with parallel wires is shown under low-conductance conditions (10−4 S/m), but electrothermal flow overcomes DEP forces under high conductance conditions (>0.1 S/m). Planar devices are shown to be effective under high conductance conditions (∼1 S/m) without the deleterious effects of electrothermal flow. This study provides new insights into design compromises and limitations for producing future electrokinetic devices for better performance with high conductance solutions.

AB - The quest for new cell-free DNA and exosome biomarker-based molecular diagnostics require fast and efficient sample preparation techniques. Conventional methods for isolating these biomarkers from blood are both time-consuming and laborious. New electrokinetic microarray devices using dielectrophoresis (DEP) to isolate cell-free DNA and exosome biomarkers have now greatly improved the sample preparation process. Nevertheless, these devices still have some limitations when used with high conductance biological fluids, e.g. blood, plasma, and serum. This study demonstrates that electrochemical damage may occur on the platinum electrodes of DEP microarray devices. It further examines two model device designs that include a parallel wire arrangement and a planar array. Effective isolation of fluorescent beads with parallel wires is shown under low-conductance conditions (10−4 S/m), but electrothermal flow overcomes DEP forces under high conductance conditions (>0.1 S/m). Planar devices are shown to be effective under high conductance conditions (∼1 S/m) without the deleterious effects of electrothermal flow. This study provides new insights into design compromises and limitations for producing future electrokinetic devices for better performance with high conductance solutions.

KW - Blood

KW - Cell-free DNA

KW - Dielectrophoresis

KW - Exosomes

KW - Plasma

UR - http://www.scopus.com/inward/record.url?scp=85019981208&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85019981208&partnerID=8YFLogxK

U2 - 10.1002/elps.201600563

DO - 10.1002/elps.201600563

M3 - Article

C2 - 28401635

AN - SCOPUS:85019981208

VL - 38

SP - 1475

EP - 1482

JO - Electrophoresis

JF - Electrophoresis

SN - 0173-0835

IS - 11

ER -