Effect of coronary occlusion on intracardiac electrogram morphology

G. Stuart Mendenhall, Firas Zahr, Sanjoy Bhattacharya, Catalin Toma, Samir Saba

Research output: Contribution to journalArticle

Abstract

Aims The effect of coronary occlusion on the morphology of intracardiac electrograms (IKG) may be of diagnostic value in recipients of cardiac implantable electronic device (CIED) and in other patients at risk of ischaemic heart disease (IHD), but remains grossly uncharacterized. The aim of the current study was to examine the effect of total occlusions in the major coronary artery distributions on the IKG.Methods and resultsDomestic crossbred pigs (n 11, 2030 kg) were implanted with dual-coil right ventricular defibrillators, and bipolar right atrial and left ventricular leads. Through the femoral approach, percutaneous balloon total occlusion of the major coronary arteries was performed in random order in the left anterior descending, left circumflex, and right coronary arteries. Each occlusion was maintained for 35 min with 30 min periods of reperfusion in between. Simultaneous 15-vector IKG and 12-lead surface electrocardiograms (ECG) were recorded and analysed at baseline and during coronary occlusions. With coronary occlusions, significant ST-segment disturbances are consistently seen on both surface ECG leads and IKG tracings compared with baseline recordings and are reproducible over time. Given the multiple intracardiac recording vectors, each occluded vessel has a specific signature, allowing coronary localization from the IKG.ConclusionsTotal coronary occlusion induces consistent IKG changes with injury patterns that allow the detection and localization of the culprit coronary artery. If duplicated in patients with IHD, these changes are likely to improve the time to diagnosis of acute coronary syndromes and thus favourably impact clinical outcomes.

Original languageEnglish (US)
Pages (from-to)1524-1531
Number of pages8
JournalEuropace
Volume14
Issue number10
DOIs
StatePublished - Oct 2012
Externally publishedYes

Fingerprint

Cardiac Electrophysiologic Techniques
Coronary Occlusion
Coronary Vessels
Myocardial Ischemia
Electrocardiography
Balloon Occlusion
Defibrillators
Acute Coronary Syndrome
Thigh
Reperfusion
Swine
Equipment and Supplies
Wounds and Injuries

Keywords

  • Coronary occlusion
  • Intracardiac electrogram
  • Myocardial infarction
  • Pig
  • Surface electrocardiogram

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Physiology (medical)

Cite this

Mendenhall, G. S., Zahr, F., Bhattacharya, S., Toma, C., & Saba, S. (2012). Effect of coronary occlusion on intracardiac electrogram morphology. Europace, 14(10), 1524-1531. https://doi.org/10.1093/europace/eus098

Effect of coronary occlusion on intracardiac electrogram morphology. / Mendenhall, G. Stuart; Zahr, Firas; Bhattacharya, Sanjoy; Toma, Catalin; Saba, Samir.

In: Europace, Vol. 14, No. 10, 10.2012, p. 1524-1531.

Research output: Contribution to journalArticle

Mendenhall, GS, Zahr, F, Bhattacharya, S, Toma, C & Saba, S 2012, 'Effect of coronary occlusion on intracardiac electrogram morphology', Europace, vol. 14, no. 10, pp. 1524-1531. https://doi.org/10.1093/europace/eus098
Mendenhall, G. Stuart ; Zahr, Firas ; Bhattacharya, Sanjoy ; Toma, Catalin ; Saba, Samir. / Effect of coronary occlusion on intracardiac electrogram morphology. In: Europace. 2012 ; Vol. 14, No. 10. pp. 1524-1531.
@article{a8155c580bfc46489e71016988581d7b,
title = "Effect of coronary occlusion on intracardiac electrogram morphology",
abstract = "Aims The effect of coronary occlusion on the morphology of intracardiac electrograms (IKG) may be of diagnostic value in recipients of cardiac implantable electronic device (CIED) and in other patients at risk of ischaemic heart disease (IHD), but remains grossly uncharacterized. The aim of the current study was to examine the effect of total occlusions in the major coronary artery distributions on the IKG.Methods and resultsDomestic crossbred pigs (n 11, 2030 kg) were implanted with dual-coil right ventricular defibrillators, and bipolar right atrial and left ventricular leads. Through the femoral approach, percutaneous balloon total occlusion of the major coronary arteries was performed in random order in the left anterior descending, left circumflex, and right coronary arteries. Each occlusion was maintained for 35 min with 30 min periods of reperfusion in between. Simultaneous 15-vector IKG and 12-lead surface electrocardiograms (ECG) were recorded and analysed at baseline and during coronary occlusions. With coronary occlusions, significant ST-segment disturbances are consistently seen on both surface ECG leads and IKG tracings compared with baseline recordings and are reproducible over time. Given the multiple intracardiac recording vectors, each occluded vessel has a specific signature, allowing coronary localization from the IKG.ConclusionsTotal coronary occlusion induces consistent IKG changes with injury patterns that allow the detection and localization of the culprit coronary artery. If duplicated in patients with IHD, these changes are likely to improve the time to diagnosis of acute coronary syndromes and thus favourably impact clinical outcomes.",
keywords = "Coronary occlusion, Intracardiac electrogram, Myocardial infarction, Pig, Surface electrocardiogram",
author = "Mendenhall, {G. Stuart} and Firas Zahr and Sanjoy Bhattacharya and Catalin Toma and Samir Saba",
year = "2012",
month = "10",
doi = "10.1093/europace/eus098",
language = "English (US)",
volume = "14",
pages = "1524--1531",
journal = "Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology",
issn = "1099-5129",
publisher = "Oxford University Press",
number = "10",

}

TY - JOUR

T1 - Effect of coronary occlusion on intracardiac electrogram morphology

AU - Mendenhall, G. Stuart

AU - Zahr, Firas

AU - Bhattacharya, Sanjoy

AU - Toma, Catalin

AU - Saba, Samir

PY - 2012/10

Y1 - 2012/10

N2 - Aims The effect of coronary occlusion on the morphology of intracardiac electrograms (IKG) may be of diagnostic value in recipients of cardiac implantable electronic device (CIED) and in other patients at risk of ischaemic heart disease (IHD), but remains grossly uncharacterized. The aim of the current study was to examine the effect of total occlusions in the major coronary artery distributions on the IKG.Methods and resultsDomestic crossbred pigs (n 11, 2030 kg) were implanted with dual-coil right ventricular defibrillators, and bipolar right atrial and left ventricular leads. Through the femoral approach, percutaneous balloon total occlusion of the major coronary arteries was performed in random order in the left anterior descending, left circumflex, and right coronary arteries. Each occlusion was maintained for 35 min with 30 min periods of reperfusion in between. Simultaneous 15-vector IKG and 12-lead surface electrocardiograms (ECG) were recorded and analysed at baseline and during coronary occlusions. With coronary occlusions, significant ST-segment disturbances are consistently seen on both surface ECG leads and IKG tracings compared with baseline recordings and are reproducible over time. Given the multiple intracardiac recording vectors, each occluded vessel has a specific signature, allowing coronary localization from the IKG.ConclusionsTotal coronary occlusion induces consistent IKG changes with injury patterns that allow the detection and localization of the culprit coronary artery. If duplicated in patients with IHD, these changes are likely to improve the time to diagnosis of acute coronary syndromes and thus favourably impact clinical outcomes.

AB - Aims The effect of coronary occlusion on the morphology of intracardiac electrograms (IKG) may be of diagnostic value in recipients of cardiac implantable electronic device (CIED) and in other patients at risk of ischaemic heart disease (IHD), but remains grossly uncharacterized. The aim of the current study was to examine the effect of total occlusions in the major coronary artery distributions on the IKG.Methods and resultsDomestic crossbred pigs (n 11, 2030 kg) were implanted with dual-coil right ventricular defibrillators, and bipolar right atrial and left ventricular leads. Through the femoral approach, percutaneous balloon total occlusion of the major coronary arteries was performed in random order in the left anterior descending, left circumflex, and right coronary arteries. Each occlusion was maintained for 35 min with 30 min periods of reperfusion in between. Simultaneous 15-vector IKG and 12-lead surface electrocardiograms (ECG) were recorded and analysed at baseline and during coronary occlusions. With coronary occlusions, significant ST-segment disturbances are consistently seen on both surface ECG leads and IKG tracings compared with baseline recordings and are reproducible over time. Given the multiple intracardiac recording vectors, each occluded vessel has a specific signature, allowing coronary localization from the IKG.ConclusionsTotal coronary occlusion induces consistent IKG changes with injury patterns that allow the detection and localization of the culprit coronary artery. If duplicated in patients with IHD, these changes are likely to improve the time to diagnosis of acute coronary syndromes and thus favourably impact clinical outcomes.

KW - Coronary occlusion

KW - Intracardiac electrogram

KW - Myocardial infarction

KW - Pig

KW - Surface electrocardiogram

UR - http://www.scopus.com/inward/record.url?scp=84866915638&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84866915638&partnerID=8YFLogxK

U2 - 10.1093/europace/eus098

DO - 10.1093/europace/eus098

M3 - Article

C2 - 22514132

AN - SCOPUS:84866915638

VL - 14

SP - 1524

EP - 1531

JO - Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

JF - Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

SN - 1099-5129

IS - 10

ER -