Introduction: Root canal irrigation carries a risk of extrusion of irrigant into the periapical tissues. The objective of this study was to compare different irrigation systems in matched pairs of teeth prepared to an apical size of 35.06 and 50.06 by measuring the frequency and extent of apical extrusion of sodium hypochlorite (NaOCl) into a simulated periapical environment. The null hypothesis was tested that there is no difference between systems. Methods: Bilaterally matched pairs (n = 10) of single-canal extracted human anterior teeth were instrumented to an apical size of either 35.06 or 50.06. Teeth were embedded in a gel containing the pH-sensitive dye M-cresol purple that changes from yellow at pH 7.4 to purple at pH 9. Root canals were irrigated with 6% NaOCl (pH 11) by using EndoActivator (EA), EndoVac (EV), Rispi-Sonic/MicroMega 1500 (MM), passive ultrasonic irrigation (PUI), and syringe irrigation with a slot-tipped needle (SN), so that each tooth underwent all irrigation procedures in a randomized crossover design. Apical extrusion was evaluated by image analyses. Results: The frequency of extrusion was less in teeth with apical preparation size 35.06 (36%) compared with 50.06 (60%) (P =.014) and was dependent on the irrigation system in 35.06 (P =.039) but not 50.06 groups. In the 35.06 group the frequency of extrusion was less for EV than for MM and SN (both P =.029). The extent of extrusion was less for MM compared with PUI (P = .024) and SN (P =.046) in the 35.06 group and greater for SN compared with all other systems in the 50.06 group (P

Original languageEnglish (US)
Pages (from-to)1677-1681
Number of pages5
JournalJournal of Endodontics
Volume37
Issue number12
DOIs
StatePublished - Dec 2011

Fingerprint

Sodium Hypochlorite
Dental Pulp Cavity
Tooth
Needles
cresol
Ultrasonics
Periapical Tissue
Syringes
Cross-Over Studies
Coloring Agents
Gels

Keywords

  • Apical extrusion
  • EndoActivator
  • EndoVac
  • Irrisafe
  • passive ultrasonic irrigation
  • root canal irrigation
  • sodium hypochlorite
  • Sonic Air MicroMega

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Apical extrusion of sodium hypochlorite using different root canal irrigation systems. / Mitchell, Ross P.; Baumgartner, John (Craig); Sedgley, Christine.

In: Journal of Endodontics, Vol. 37, No. 12, 12.2011, p. 1677-1681.

Research output: Contribution to journalArticle

@article{34b00663e6f74be991a966735b18431d,
title = "Apical extrusion of sodium hypochlorite using different root canal irrigation systems",
abstract = "Introduction: Root canal irrigation carries a risk of extrusion of irrigant into the periapical tissues. The objective of this study was to compare different irrigation systems in matched pairs of teeth prepared to an apical size of 35.06 and 50.06 by measuring the frequency and extent of apical extrusion of sodium hypochlorite (NaOCl) into a simulated periapical environment. The null hypothesis was tested that there is no difference between systems. Methods: Bilaterally matched pairs (n = 10) of single-canal extracted human anterior teeth were instrumented to an apical size of either 35.06 or 50.06. Teeth were embedded in a gel containing the pH-sensitive dye M-cresol purple that changes from yellow at pH 7.4 to purple at pH 9. Root canals were irrigated with 6{\%} NaOCl (pH 11) by using EndoActivator (EA), EndoVac (EV), Rispi-Sonic/MicroMega 1500 (MM), passive ultrasonic irrigation (PUI), and syringe irrigation with a slot-tipped needle (SN), so that each tooth underwent all irrigation procedures in a randomized crossover design. Apical extrusion was evaluated by image analyses. Results: The frequency of extrusion was less in teeth with apical preparation size 35.06 (36{\%}) compared with 50.06 (60{\%}) (P =.014) and was dependent on the irrigation system in 35.06 (P =.039) but not 50.06 groups. In the 35.06 group the frequency of extrusion was less for EV than for MM and SN (both P =.029). The extent of extrusion was less for MM compared with PUI (P = .024) and SN (P =.046) in the 35.06 group and greater for SN compared with all other systems in the 50.06 group (P",
keywords = "Apical extrusion, EndoActivator, EndoVac, Irrisafe, passive ultrasonic irrigation, root canal irrigation, sodium hypochlorite, Sonic Air MicroMega",
author = "Mitchell, {Ross P.} and Baumgartner, {John (Craig)} and Christine Sedgley",
year = "2011",
month = "12",
doi = "10.1016/j.joen.2011.09.004",
language = "English (US)",
volume = "37",
pages = "1677--1681",
journal = "Journal of Endodontics",
issn = "0099-2399",
publisher = "Elsevier Inc.",
number = "12",

}

TY - JOUR

T1 - Apical extrusion of sodium hypochlorite using different root canal irrigation systems

AU - Mitchell, Ross P.

AU - Baumgartner, John (Craig)

AU - Sedgley, Christine

PY - 2011/12

Y1 - 2011/12

N2 - Introduction: Root canal irrigation carries a risk of extrusion of irrigant into the periapical tissues. The objective of this study was to compare different irrigation systems in matched pairs of teeth prepared to an apical size of 35.06 and 50.06 by measuring the frequency and extent of apical extrusion of sodium hypochlorite (NaOCl) into a simulated periapical environment. The null hypothesis was tested that there is no difference between systems. Methods: Bilaterally matched pairs (n = 10) of single-canal extracted human anterior teeth were instrumented to an apical size of either 35.06 or 50.06. Teeth were embedded in a gel containing the pH-sensitive dye M-cresol purple that changes from yellow at pH 7.4 to purple at pH 9. Root canals were irrigated with 6% NaOCl (pH 11) by using EndoActivator (EA), EndoVac (EV), Rispi-Sonic/MicroMega 1500 (MM), passive ultrasonic irrigation (PUI), and syringe irrigation with a slot-tipped needle (SN), so that each tooth underwent all irrigation procedures in a randomized crossover design. Apical extrusion was evaluated by image analyses. Results: The frequency of extrusion was less in teeth with apical preparation size 35.06 (36%) compared with 50.06 (60%) (P =.014) and was dependent on the irrigation system in 35.06 (P =.039) but not 50.06 groups. In the 35.06 group the frequency of extrusion was less for EV than for MM and SN (both P =.029). The extent of extrusion was less for MM compared with PUI (P = .024) and SN (P =.046) in the 35.06 group and greater for SN compared with all other systems in the 50.06 group (P

AB - Introduction: Root canal irrigation carries a risk of extrusion of irrigant into the periapical tissues. The objective of this study was to compare different irrigation systems in matched pairs of teeth prepared to an apical size of 35.06 and 50.06 by measuring the frequency and extent of apical extrusion of sodium hypochlorite (NaOCl) into a simulated periapical environment. The null hypothesis was tested that there is no difference between systems. Methods: Bilaterally matched pairs (n = 10) of single-canal extracted human anterior teeth were instrumented to an apical size of either 35.06 or 50.06. Teeth were embedded in a gel containing the pH-sensitive dye M-cresol purple that changes from yellow at pH 7.4 to purple at pH 9. Root canals were irrigated with 6% NaOCl (pH 11) by using EndoActivator (EA), EndoVac (EV), Rispi-Sonic/MicroMega 1500 (MM), passive ultrasonic irrigation (PUI), and syringe irrigation with a slot-tipped needle (SN), so that each tooth underwent all irrigation procedures in a randomized crossover design. Apical extrusion was evaluated by image analyses. Results: The frequency of extrusion was less in teeth with apical preparation size 35.06 (36%) compared with 50.06 (60%) (P =.014) and was dependent on the irrigation system in 35.06 (P =.039) but not 50.06 groups. In the 35.06 group the frequency of extrusion was less for EV than for MM and SN (both P =.029). The extent of extrusion was less for MM compared with PUI (P = .024) and SN (P =.046) in the 35.06 group and greater for SN compared with all other systems in the 50.06 group (P

KW - Apical extrusion

KW - EndoActivator

KW - EndoVac

KW - Irrisafe

KW - passive ultrasonic irrigation

KW - root canal irrigation

KW - sodium hypochlorite

KW - Sonic Air MicroMega

UR - http://www.scopus.com/inward/record.url?scp=81755174219&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=81755174219&partnerID=8YFLogxK

U2 - 10.1016/j.joen.2011.09.004

DO - 10.1016/j.joen.2011.09.004

M3 - Article

C2 - 22099904

AN - SCOPUS:81755174219

VL - 37

SP - 1677

EP - 1681

JO - Journal of Endodontics

JF - Journal of Endodontics

SN - 0099-2399

IS - 12

ER -