Accuracy of real-time, three-dimensional Doppler echocardiography for stroke volume estimation compared with phase-encoded MRI: An in vivo study

J. Pemberton, M. Jerosch-Herold, Xin Li, L. Hui, Gary (Michael) Silberbach, W. Woodward, K. Thiele, A. Kenny, David Sahn

Research output: Contribution to journalArticle

12 Citations (Scopus)
Original languageEnglish (US)
Pages (from-to)1212-1213
Number of pages2
JournalHeart
Volume94
Issue number9
DOIs
StatePublished - Sep 2008

Fingerprint

Computer Assisted Image Interpretation
Three-Dimensional Echocardiography
Aortic Coarctation
Doppler Echocardiography
Stroke Volume
Case-Control Studies
Magnetic Resonance Imaging
Sensitivity and Specificity

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Accuracy of real-time, three-dimensional Doppler echocardiography for stroke volume estimation compared with phase-encoded MRI : An in vivo study. / Pemberton, J.; Jerosch-Herold, M.; Li, Xin; Hui, L.; Silberbach, Gary (Michael); Woodward, W.; Thiele, K.; Kenny, A.; Sahn, David.

In: Heart, Vol. 94, No. 9, 09.2008, p. 1212-1213.

Research output: Contribution to journalArticle

Pemberton, J. ; Jerosch-Herold, M. ; Li, Xin ; Hui, L. ; Silberbach, Gary (Michael) ; Woodward, W. ; Thiele, K. ; Kenny, A. ; Sahn, David. / Accuracy of real-time, three-dimensional Doppler echocardiography for stroke volume estimation compared with phase-encoded MRI : An in vivo study. In: Heart. 2008 ; Vol. 94, No. 9. pp. 1212-1213.
@article{55748af7ed014521bde28da381e0184d,
title = "Accuracy of real-time, three-dimensional Doppler echocardiography for stroke volume estimation compared with phase-encoded MRI: An in vivo study",
author = "J. Pemberton and M. Jerosch-Herold and Xin Li and L. Hui and Silberbach, {Gary (Michael)} and W. Woodward and K. Thiele and A. Kenny and David Sahn",
year = "2008",
month = "9",
doi = "10.1136/hrt.2008.147751",
language = "English (US)",
volume = "94",
pages = "1212--1213",
journal = "Heart",
issn = "1355-6037",
publisher = "BMJ Publishing Group",
number = "9",

}

TY - JOUR

T1 - Accuracy of real-time, three-dimensional Doppler echocardiography for stroke volume estimation compared with phase-encoded MRI

T2 - An in vivo study

AU - Pemberton, J.

AU - Jerosch-Herold, M.

AU - Li, Xin

AU - Hui, L.

AU - Silberbach, Gary (Michael)

AU - Woodward, W.

AU - Thiele, K.

AU - Kenny, A.

AU - Sahn, David

PY - 2008/9

Y1 - 2008/9

UR - http://www.scopus.com/inward/record.url?scp=50249107876&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=50249107876&partnerID=8YFLogxK

U2 - 10.1136/hrt.2008.147751

DO - 10.1136/hrt.2008.147751

M3 - Article

C2 - 18703699

AN - SCOPUS:50249107876

VL - 94

SP - 1212

EP - 1213

JO - Heart

JF - Heart

SN - 1355-6037

IS - 9