Variability in interpretive performance at screening mammography and radiologists' characteristics associated with accuracy

Joann G. Elmore, Sara L. Jackson, Linn Abraham, Diana L. Miglioretti, Patricia A. Carney, Berta M. Geller, Bonnie C. Yankaskas, Karla Kerlikowske, Tracy Onega, Robert D. Rosenberg, Edward A. Sickles, Diana S.M. Buist

Research output: Contribution to journalArticlepeer-review

209 Scopus citations

Abstract

Purpose: To identify radiologists' characteristics associated with interpretive performance in screening mammography. Materials and Methods: The study was approved by institutional review boards of University of Washington (Seattle, Wash) and institutions at seven Breast Cancer Surveillance Consortium sites, informed consent was obtained, and procedures were HIPAA compliant. Radiologists who interpreted mammograms in seven U.S. regions completed a self-administered mailed survey; information on demographics, practice type, and experience in and perceptions of general radiology and breast imaging was collected. Survey data were linked to data on screening mammograms the radiologists interpreted between January 1, 1998, and December 31, 2005, and included patient risk factors, Breast Imaging Reporting and Data System assessment, and follow-up breast cancer data. The survey was returned by 71% (257 of 364) of radiologists; in 56% (205 of 364) of the eligible radiologists, complete data on screening mammograms during the study period were provided; these data were used in the final analysis. An evaluation of whether the radiologists' characteristics were associated with recall rate, false-positive rate, sensitivity, or positive predictive value of recall (PPV1) of the screening examinations was performed with logistic regression models that were adjusted for patients' characteristics and radiologist-specific random effects. Results: Study radiologists interpreted 1 036 155 screening mammograms; 4961 breast cancers were detected. Median percentages and interquartile ranges, respectively, were as follows: recall rate, 9.3% and 6.3%-13.2%; false-positive rate, 8.9% and 5.9%-12.8%; sensitivity, 83.8% and 74.5%-92.3%; and PPV1, 4.0% and 2.6%-5.9%. Wide variability in sensitivity was noted, even among radiologists with similar false-positive rates. In adjusted regression models, female radiologists or fellowship-trained radiologists had significantly higher recall and false-positive rates (P < .05, all). Fellowship training in breast imaging was the only characteristic significantly associated with improved sensitivity (odds ratio, 2.32; 95% confidence interval: 1.42, 3.80; P < .001) and the overall accuracy parameter (odds ratio, 1.61; 95% confidence interval: 1.05, 2.45; P = .028). Conclusion: Fellowship training in breast imaging may lead to improved cancer detection, but it is associated with higher false-positive rates.

Original languageEnglish (US)
Pages (from-to)641-651
Number of pages11
JournalRADIOLOGY
Volume253
Issue number3
DOIs
StatePublished - Dec 2009

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Variability in interpretive performance at screening mammography and radiologists' characteristics associated with accuracy'. Together they form a unique fingerprint.

Cite this