Validity of microsphere depositions for regional myocardial flows

J. B. Bassingthwaighte, M. A. Malone, T. C. Moffett, R. B. King, S. E. Little, Jeanne Link, Kenneth Krohn

Research output: Contribution to journalArticle

109 Citations (Scopus)

Abstract

Due to the particulate nature of microspheres, their deposition in small-tissue regions may not be strictly flow dependent. To evaluate the importance of rheological and geometric factors and random error, their deposition densities in small regions of rabbit hearts were examined in comparison with those of a new 'molecular microsphere', 2-iododesmethylimipramine (IDMI), whose high lipid solubility allows it to be delivered into tissue in proportion to flow, and whose binding in tissue prevents rapid washout. 141Ce- and 103Ru-labeled 16.5-μm spheres in one syringe and [125I]- and [131I]DMI in another syringe were injected simultaneously into the left atrium of open-chest rabbits, while obtaining reference blood samples from the femoral artery. Hearts were removed 1 min after injection, cut into ~100 pieces averaging 54 mg, and the regional deposition densities calculated for each tracer from the isotopic counts. Correlations between the differently labeled microspheres were r > 0.95 and for the two IDMIs were >0.98. Scatter plots of sphere densities vs. IDMI densities showed that differences between microspheres and IDMI had substantial scatter, 0.87 <r <0.96 and were not random. Microsphere depositions tended to be lower than IDMI depositions at low flows and higher at high flows. The tendency for spheres to be deposited preferentially in high-flow regions may be explained by a bias at bifurcations toward entering the branch with higher flow and secondarily toward entering those branches that are straighter. We conclude that microspheres are generally adequate for estimating regional flows but suffer systematic error when the regions of interest are supplied via arteries of diameters only a few times those of the microspheres.

Original languageEnglish (US)
JournalAmerican Journal of Physiology - Heart and Circulatory Physiology
Volume253
Issue number1
StatePublished - 1987
Externally publishedYes

Fingerprint

Microspheres
Syringes
Rabbits
Femoral Artery
Heart Atria
Solubility
Thorax
Arteries
Lipids
Injections
2-iododesmethylimipramine

ASJC Scopus subject areas

  • Physiology

Cite this

Bassingthwaighte, J. B., Malone, M. A., Moffett, T. C., King, R. B., Little, S. E., Link, J., & Krohn, K. (1987). Validity of microsphere depositions for regional myocardial flows. American Journal of Physiology - Heart and Circulatory Physiology, 253(1).

Validity of microsphere depositions for regional myocardial flows. / Bassingthwaighte, J. B.; Malone, M. A.; Moffett, T. C.; King, R. B.; Little, S. E.; Link, Jeanne; Krohn, Kenneth.

In: American Journal of Physiology - Heart and Circulatory Physiology, Vol. 253, No. 1, 1987.

Research output: Contribution to journalArticle

Bassingthwaighte, J. B. ; Malone, M. A. ; Moffett, T. C. ; King, R. B. ; Little, S. E. ; Link, Jeanne ; Krohn, Kenneth. / Validity of microsphere depositions for regional myocardial flows. In: American Journal of Physiology - Heart and Circulatory Physiology. 1987 ; Vol. 253, No. 1.
@article{007221a9e1b34426987e3772ddc9c039,
title = "Validity of microsphere depositions for regional myocardial flows",
abstract = "Due to the particulate nature of microspheres, their deposition in small-tissue regions may not be strictly flow dependent. To evaluate the importance of rheological and geometric factors and random error, their deposition densities in small regions of rabbit hearts were examined in comparison with those of a new 'molecular microsphere', 2-iododesmethylimipramine (IDMI), whose high lipid solubility allows it to be delivered into tissue in proportion to flow, and whose binding in tissue prevents rapid washout. 141Ce- and 103Ru-labeled 16.5-μm spheres in one syringe and [125I]- and [131I]DMI in another syringe were injected simultaneously into the left atrium of open-chest rabbits, while obtaining reference blood samples from the femoral artery. Hearts were removed 1 min after injection, cut into ~100 pieces averaging 54 mg, and the regional deposition densities calculated for each tracer from the isotopic counts. Correlations between the differently labeled microspheres were r > 0.95 and for the two IDMIs were >0.98. Scatter plots of sphere densities vs. IDMI densities showed that differences between microspheres and IDMI had substantial scatter, 0.87",
author = "Bassingthwaighte, {J. B.} and Malone, {M. A.} and Moffett, {T. C.} and King, {R. B.} and Little, {S. E.} and Jeanne Link and Kenneth Krohn",
year = "1987",
language = "English (US)",
volume = "253",
journal = "American Journal of Physiology - Renal Fluid and Electrolyte Physiology",
issn = "1931-857X",
publisher = "American Physiological Society",
number = "1",

}

TY - JOUR

T1 - Validity of microsphere depositions for regional myocardial flows

AU - Bassingthwaighte, J. B.

AU - Malone, M. A.

AU - Moffett, T. C.

AU - King, R. B.

AU - Little, S. E.

AU - Link, Jeanne

AU - Krohn, Kenneth

PY - 1987

Y1 - 1987

N2 - Due to the particulate nature of microspheres, their deposition in small-tissue regions may not be strictly flow dependent. To evaluate the importance of rheological and geometric factors and random error, their deposition densities in small regions of rabbit hearts were examined in comparison with those of a new 'molecular microsphere', 2-iododesmethylimipramine (IDMI), whose high lipid solubility allows it to be delivered into tissue in proportion to flow, and whose binding in tissue prevents rapid washout. 141Ce- and 103Ru-labeled 16.5-μm spheres in one syringe and [125I]- and [131I]DMI in another syringe were injected simultaneously into the left atrium of open-chest rabbits, while obtaining reference blood samples from the femoral artery. Hearts were removed 1 min after injection, cut into ~100 pieces averaging 54 mg, and the regional deposition densities calculated for each tracer from the isotopic counts. Correlations between the differently labeled microspheres were r > 0.95 and for the two IDMIs were >0.98. Scatter plots of sphere densities vs. IDMI densities showed that differences between microspheres and IDMI had substantial scatter, 0.87

AB - Due to the particulate nature of microspheres, their deposition in small-tissue regions may not be strictly flow dependent. To evaluate the importance of rheological and geometric factors and random error, their deposition densities in small regions of rabbit hearts were examined in comparison with those of a new 'molecular microsphere', 2-iododesmethylimipramine (IDMI), whose high lipid solubility allows it to be delivered into tissue in proportion to flow, and whose binding in tissue prevents rapid washout. 141Ce- and 103Ru-labeled 16.5-μm spheres in one syringe and [125I]- and [131I]DMI in another syringe were injected simultaneously into the left atrium of open-chest rabbits, while obtaining reference blood samples from the femoral artery. Hearts were removed 1 min after injection, cut into ~100 pieces averaging 54 mg, and the regional deposition densities calculated for each tracer from the isotopic counts. Correlations between the differently labeled microspheres were r > 0.95 and for the two IDMIs were >0.98. Scatter plots of sphere densities vs. IDMI densities showed that differences between microspheres and IDMI had substantial scatter, 0.87

UR - http://www.scopus.com/inward/record.url?scp=0023236930&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023236930&partnerID=8YFLogxK

M3 - Article

VL - 253

JO - American Journal of Physiology - Renal Fluid and Electrolyte Physiology

JF - American Journal of Physiology - Renal Fluid and Electrolyte Physiology

SN - 1931-857X

IS - 1

ER -