Abstract

Contrast echocardiography has achieved importance in the diagnosis of cardiac shunt lesions. The technique provides information about flow patterns and serves as an adjunct to identifying communications that may be too small to image, even with high resolution real time scanning. This report reviews clinial applications and experiences in the use of standard, peripherally injected echocardiographic contrast agents for the detection of atrial septal defect, ventricular septal defect and patent ductus arteriosus. The importance and development of transpulmonary contrast agents capable of crossing the pulmonary capillary bed to opacify the left ventricle are reviewed and experience with a variety of experimental echocardiographic contrast agents is presented. Agent opacifying the left ventricle after intravenous injection are capable of providing direct ultrasonic contrast imaging of congenital left to right shunts. Further, recent experience with an experimental standardized, gas-producing contrast agent in an open chest animal model with an experimentally produced ventricular septal defect suggests that a combination of an experimental right heart agent that produces a measurable and reproducible amount of contrast effect, with a videodensitometric system capable of quantifying both positive and negative contrast effects, may provide an ultrasonic method for evaluating the magnitude of cardiac shunts.

Original languageEnglish (US)
Pages (from-to)978-985
Number of pages8
JournalJournal of the American College of Cardiology
Volume3
Issue number4
StatePublished - 1984
Externally publishedYes

Fingerprint

Ultrasonics
Contrast Media
Ventricular Heart Septal Defects
Heart Ventricles
Patent Ductus Arteriosus
Atrial Heart Septal Defects
Intravenous Injections
Echocardiography
Ultrasonography
Thorax
Animal Models
Gases
Lung

ASJC Scopus subject areas

  • Nursing(all)

Cite this

Ultrasonic contrast studies for the detection of cardiac shunts. / Valdes-Cruz, L. M.; Sahn, David.

In: Journal of the American College of Cardiology, Vol. 3, No. 4, 1984, p. 978-985.

Research output: Contribution to journalArticle

Valdes-Cruz, L. M. ; Sahn, David. / Ultrasonic contrast studies for the detection of cardiac shunts. In: Journal of the American College of Cardiology. 1984 ; Vol. 3, No. 4. pp. 978-985.
@article{f5de93bfa5a14b02bef754465e02dce9,
title = "Ultrasonic contrast studies for the detection of cardiac shunts",
abstract = "Contrast echocardiography has achieved importance in the diagnosis of cardiac shunt lesions. The technique provides information about flow patterns and serves as an adjunct to identifying communications that may be too small to image, even with high resolution real time scanning. This report reviews clinial applications and experiences in the use of standard, peripherally injected echocardiographic contrast agents for the detection of atrial septal defect, ventricular septal defect and patent ductus arteriosus. The importance and development of transpulmonary contrast agents capable of crossing the pulmonary capillary bed to opacify the left ventricle are reviewed and experience with a variety of experimental echocardiographic contrast agents is presented. Agent opacifying the left ventricle after intravenous injection are capable of providing direct ultrasonic contrast imaging of congenital left to right shunts. Further, recent experience with an experimental standardized, gas-producing contrast agent in an open chest animal model with an experimentally produced ventricular septal defect suggests that a combination of an experimental right heart agent that produces a measurable and reproducible amount of contrast effect, with a videodensitometric system capable of quantifying both positive and negative contrast effects, may provide an ultrasonic method for evaluating the magnitude of cardiac shunts.",
author = "Valdes-Cruz, {L. M.} and David Sahn",
year = "1984",
language = "English (US)",
volume = "3",
pages = "978--985",
journal = "Journal of the American College of Cardiology",
issn = "0735-1097",
publisher = "Elsevier USA",
number = "4",

}

TY - JOUR

T1 - Ultrasonic contrast studies for the detection of cardiac shunts

AU - Valdes-Cruz, L. M.

AU - Sahn, David

PY - 1984

Y1 - 1984

N2 - Contrast echocardiography has achieved importance in the diagnosis of cardiac shunt lesions. The technique provides information about flow patterns and serves as an adjunct to identifying communications that may be too small to image, even with high resolution real time scanning. This report reviews clinial applications and experiences in the use of standard, peripherally injected echocardiographic contrast agents for the detection of atrial septal defect, ventricular septal defect and patent ductus arteriosus. The importance and development of transpulmonary contrast agents capable of crossing the pulmonary capillary bed to opacify the left ventricle are reviewed and experience with a variety of experimental echocardiographic contrast agents is presented. Agent opacifying the left ventricle after intravenous injection are capable of providing direct ultrasonic contrast imaging of congenital left to right shunts. Further, recent experience with an experimental standardized, gas-producing contrast agent in an open chest animal model with an experimentally produced ventricular septal defect suggests that a combination of an experimental right heart agent that produces a measurable and reproducible amount of contrast effect, with a videodensitometric system capable of quantifying both positive and negative contrast effects, may provide an ultrasonic method for evaluating the magnitude of cardiac shunts.

AB - Contrast echocardiography has achieved importance in the diagnosis of cardiac shunt lesions. The technique provides information about flow patterns and serves as an adjunct to identifying communications that may be too small to image, even with high resolution real time scanning. This report reviews clinial applications and experiences in the use of standard, peripherally injected echocardiographic contrast agents for the detection of atrial septal defect, ventricular septal defect and patent ductus arteriosus. The importance and development of transpulmonary contrast agents capable of crossing the pulmonary capillary bed to opacify the left ventricle are reviewed and experience with a variety of experimental echocardiographic contrast agents is presented. Agent opacifying the left ventricle after intravenous injection are capable of providing direct ultrasonic contrast imaging of congenital left to right shunts. Further, recent experience with an experimental standardized, gas-producing contrast agent in an open chest animal model with an experimentally produced ventricular septal defect suggests that a combination of an experimental right heart agent that produces a measurable and reproducible amount of contrast effect, with a videodensitometric system capable of quantifying both positive and negative contrast effects, may provide an ultrasonic method for evaluating the magnitude of cardiac shunts.

UR - http://www.scopus.com/inward/record.url?scp=0021343070&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0021343070&partnerID=8YFLogxK

M3 - Article

VL - 3

SP - 978

EP - 985

JO - Journal of the American College of Cardiology

JF - Journal of the American College of Cardiology

SN - 0735-1097

IS - 4

ER -