Threshold-dependent variability of coronary artery calcification measurements - Implications for contrast-enhanced multi-detector row-computed tomography

Fabian Moselewski, Maros Ferencik, Stephan Achenbach, Suhny Abbara, Ricardo C. Cury, Sarah L. Booth, Ik Kyung Jang, Thomas J. Brady, Udo Hoffmann

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM]) at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 ± 68.7 HU versus 295 ± 65 HU (p <0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p <0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p <0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT.

Original languageEnglish (US)
Pages (from-to)390-395
Number of pages6
JournalEuropean Journal of Radiology
Volume57
Issue number3
DOIs
StatePublished - Mar 2006
Externally publishedYes

Fingerprint

Coronary Vessels
Tomography
Minerals

Keywords

  • Calcification
  • Computed tomography (CT)
  • Coronary vessels
  • Experimental studies

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Threshold-dependent variability of coronary artery calcification measurements - Implications for contrast-enhanced multi-detector row-computed tomography. / Moselewski, Fabian; Ferencik, Maros; Achenbach, Stephan; Abbara, Suhny; Cury, Ricardo C.; Booth, Sarah L.; Jang, Ik Kyung; Brady, Thomas J.; Hoffmann, Udo.

In: European Journal of Radiology, Vol. 57, No. 3, 03.2006, p. 390-395.

Research output: Contribution to journalArticle

Moselewski, Fabian ; Ferencik, Maros ; Achenbach, Stephan ; Abbara, Suhny ; Cury, Ricardo C. ; Booth, Sarah L. ; Jang, Ik Kyung ; Brady, Thomas J. ; Hoffmann, Udo. / Threshold-dependent variability of coronary artery calcification measurements - Implications for contrast-enhanced multi-detector row-computed tomography. In: European Journal of Radiology. 2006 ; Vol. 57, No. 3. pp. 390-395.
@article{b684a80839ce4ca88912ecc6f09715e3,
title = "Threshold-dependent variability of coronary artery calcification measurements - Implications for contrast-enhanced multi-detector row-computed tomography",
abstract = "Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM]) at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 ± 68.7 HU versus 295 ± 65 HU (p <0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p <0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p <0.001). These differences resulted in a change of age and gender based percentile category for AS in 78{\%} of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT.",
keywords = "Calcification, Computed tomography (CT), Coronary vessels, Experimental studies",
author = "Fabian Moselewski and Maros Ferencik and Stephan Achenbach and Suhny Abbara and Cury, {Ricardo C.} and Booth, {Sarah L.} and Jang, {Ik Kyung} and Brady, {Thomas J.} and Udo Hoffmann",
year = "2006",
month = "3",
doi = "10.1016/j.ejrad.2005.12.026",
language = "English (US)",
volume = "57",
pages = "390--395",
journal = "European Journal of Radiology",
issn = "0720-048X",
publisher = "Elsevier Ireland Ltd",
number = "3",

}

TY - JOUR

T1 - Threshold-dependent variability of coronary artery calcification measurements - Implications for contrast-enhanced multi-detector row-computed tomography

AU - Moselewski, Fabian

AU - Ferencik, Maros

AU - Achenbach, Stephan

AU - Abbara, Suhny

AU - Cury, Ricardo C.

AU - Booth, Sarah L.

AU - Jang, Ik Kyung

AU - Brady, Thomas J.

AU - Hoffmann, Udo

PY - 2006/3

Y1 - 2006/3

N2 - Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM]) at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 ± 68.7 HU versus 295 ± 65 HU (p <0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p <0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p <0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT.

AB - Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM]) at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 ± 68.7 HU versus 295 ± 65 HU (p <0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p <0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p <0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT.

KW - Calcification

KW - Computed tomography (CT)

KW - Coronary vessels

KW - Experimental studies

UR - http://www.scopus.com/inward/record.url?scp=32844467035&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=32844467035&partnerID=8YFLogxK

U2 - 10.1016/j.ejrad.2005.12.026

DO - 10.1016/j.ejrad.2005.12.026

M3 - Article

VL - 57

SP - 390

EP - 395

JO - European Journal of Radiology

JF - European Journal of Radiology

SN - 0720-048X

IS - 3

ER -