Three-dimensional reconstruction of color Doppler flow convergence regions and regurgitant jets: An in vitro quantitative study

Takahiro Shiota, Brian Sinclair, Masahiro Ishii, Xiaodong Zhou, Ge Shuping, Dag E. Teien, Morteza Gharib, David Sahn

Research output: Contribution to journalArticle

66 Citations (Scopus)

Abstract

Objectives. This study sought to investigate the applicability of a current implementation of a three-dimensional echocardiographic reconstruction method for color Doppler flow convergence and regurgitant jet imaging. Background. Evaluation of regurgitant flow events, such as flow convergences or regurgitant jets, using two-dimensional imaging ultrasound color flow Doppler systems may not be robust enough to characterize these spatially complex events. Methods. We studied two in vitro models using steady flow to optimize results. In the first constant-flow model, two different orifices were each mounted to produce flow convergences and free jets-a circular orifice and a rectangular orifice with orifice area of 0.24 cm2. In another flow model, steady flows through a circular orifice were directed toward a curved surrounding wall to produce wall adherent jets. Video composite data of color Doppler flow images from both free jet and wall jet models were reconstructed and analyzed after computer-controlled 180° rotational acquisition using a TomTec computer. Results. For the free jet model there was an excellent relation between actual flow rates and three-dimensional regurgitant jet volumes for both circular and rectangular orifices (r = 0.99 and r = 0.98, respectively). However, the rectangular orifice produced larger jet volumes than the circular orifice, even at the same flow rates (p <0.0001). Calculated flow rates by the hemispheric model using one axial measurement of the flow convergence isovelocity surface from two-dimensional color flow images underestimated actual flow rate by 35% for the circular orifice and by 44% for the rectangular orifice, whereas a hemielliptic method implemented using three axial measurements of the flow convergence zone derived using three-dimensional reconstruction correlated well with and underestimated actual flow rate to a lesser degree (22% for the circular orifice, 32% for the rectangular orifice). In the wall jet model, the jets were flattened against and spread along the wall and had reduced regurgitant jet volumes compared with free jets (p <0.01). Conclusions. Three-dimensional reconstruction of flow imaged by color Doppler may add quantitative spatial information to aid computation methods that have been used for evaluating valvular regurgitation, especially where they relate to complex geometric flow events.

Original languageEnglish (US)
Pages (from-to)1511-1518
Number of pages8
JournalJournal of the American College of Cardiology
Volume27
Issue number6
DOIs
StatePublished - May 1996

Fingerprint

Color
Ultrasonography
In Vitro Techniques

ASJC Scopus subject areas

  • Nursing(all)

Cite this

Three-dimensional reconstruction of color Doppler flow convergence regions and regurgitant jets : An in vitro quantitative study. / Shiota, Takahiro; Sinclair, Brian; Ishii, Masahiro; Zhou, Xiaodong; Shuping, Ge; Teien, Dag E.; Gharib, Morteza; Sahn, David.

In: Journal of the American College of Cardiology, Vol. 27, No. 6, 05.1996, p. 1511-1518.

Research output: Contribution to journalArticle

Shiota, Takahiro ; Sinclair, Brian ; Ishii, Masahiro ; Zhou, Xiaodong ; Shuping, Ge ; Teien, Dag E. ; Gharib, Morteza ; Sahn, David. / Three-dimensional reconstruction of color Doppler flow convergence regions and regurgitant jets : An in vitro quantitative study. In: Journal of the American College of Cardiology. 1996 ; Vol. 27, No. 6. pp. 1511-1518.
@article{6b69e741394f4b0483028aae9d1ef9e4,
title = "Three-dimensional reconstruction of color Doppler flow convergence regions and regurgitant jets: An in vitro quantitative study",
abstract = "Objectives. This study sought to investigate the applicability of a current implementation of a three-dimensional echocardiographic reconstruction method for color Doppler flow convergence and regurgitant jet imaging. Background. Evaluation of regurgitant flow events, such as flow convergences or regurgitant jets, using two-dimensional imaging ultrasound color flow Doppler systems may not be robust enough to characterize these spatially complex events. Methods. We studied two in vitro models using steady flow to optimize results. In the first constant-flow model, two different orifices were each mounted to produce flow convergences and free jets-a circular orifice and a rectangular orifice with orifice area of 0.24 cm2. In another flow model, steady flows through a circular orifice were directed toward a curved surrounding wall to produce wall adherent jets. Video composite data of color Doppler flow images from both free jet and wall jet models were reconstructed and analyzed after computer-controlled 180° rotational acquisition using a TomTec computer. Results. For the free jet model there was an excellent relation between actual flow rates and three-dimensional regurgitant jet volumes for both circular and rectangular orifices (r = 0.99 and r = 0.98, respectively). However, the rectangular orifice produced larger jet volumes than the circular orifice, even at the same flow rates (p <0.0001). Calculated flow rates by the hemispheric model using one axial measurement of the flow convergence isovelocity surface from two-dimensional color flow images underestimated actual flow rate by 35{\%} for the circular orifice and by 44{\%} for the rectangular orifice, whereas a hemielliptic method implemented using three axial measurements of the flow convergence zone derived using three-dimensional reconstruction correlated well with and underestimated actual flow rate to a lesser degree (22{\%} for the circular orifice, 32{\%} for the rectangular orifice). In the wall jet model, the jets were flattened against and spread along the wall and had reduced regurgitant jet volumes compared with free jets (p <0.01). Conclusions. Three-dimensional reconstruction of flow imaged by color Doppler may add quantitative spatial information to aid computation methods that have been used for evaluating valvular regurgitation, especially where they relate to complex geometric flow events.",
author = "Takahiro Shiota and Brian Sinclair and Masahiro Ishii and Xiaodong Zhou and Ge Shuping and Teien, {Dag E.} and Morteza Gharib and David Sahn",
year = "1996",
month = "5",
doi = "10.1016/0735-1097(96)00009-5",
language = "English (US)",
volume = "27",
pages = "1511--1518",
journal = "Journal of the American College of Cardiology",
issn = "0735-1097",
publisher = "Elsevier USA",
number = "6",

}

TY - JOUR

T1 - Three-dimensional reconstruction of color Doppler flow convergence regions and regurgitant jets

T2 - An in vitro quantitative study

AU - Shiota, Takahiro

AU - Sinclair, Brian

AU - Ishii, Masahiro

AU - Zhou, Xiaodong

AU - Shuping, Ge

AU - Teien, Dag E.

AU - Gharib, Morteza

AU - Sahn, David

PY - 1996/5

Y1 - 1996/5

N2 - Objectives. This study sought to investigate the applicability of a current implementation of a three-dimensional echocardiographic reconstruction method for color Doppler flow convergence and regurgitant jet imaging. Background. Evaluation of regurgitant flow events, such as flow convergences or regurgitant jets, using two-dimensional imaging ultrasound color flow Doppler systems may not be robust enough to characterize these spatially complex events. Methods. We studied two in vitro models using steady flow to optimize results. In the first constant-flow model, two different orifices were each mounted to produce flow convergences and free jets-a circular orifice and a rectangular orifice with orifice area of 0.24 cm2. In another flow model, steady flows through a circular orifice were directed toward a curved surrounding wall to produce wall adherent jets. Video composite data of color Doppler flow images from both free jet and wall jet models were reconstructed and analyzed after computer-controlled 180° rotational acquisition using a TomTec computer. Results. For the free jet model there was an excellent relation between actual flow rates and three-dimensional regurgitant jet volumes for both circular and rectangular orifices (r = 0.99 and r = 0.98, respectively). However, the rectangular orifice produced larger jet volumes than the circular orifice, even at the same flow rates (p <0.0001). Calculated flow rates by the hemispheric model using one axial measurement of the flow convergence isovelocity surface from two-dimensional color flow images underestimated actual flow rate by 35% for the circular orifice and by 44% for the rectangular orifice, whereas a hemielliptic method implemented using three axial measurements of the flow convergence zone derived using three-dimensional reconstruction correlated well with and underestimated actual flow rate to a lesser degree (22% for the circular orifice, 32% for the rectangular orifice). In the wall jet model, the jets were flattened against and spread along the wall and had reduced regurgitant jet volumes compared with free jets (p <0.01). Conclusions. Three-dimensional reconstruction of flow imaged by color Doppler may add quantitative spatial information to aid computation methods that have been used for evaluating valvular regurgitation, especially where they relate to complex geometric flow events.

AB - Objectives. This study sought to investigate the applicability of a current implementation of a three-dimensional echocardiographic reconstruction method for color Doppler flow convergence and regurgitant jet imaging. Background. Evaluation of regurgitant flow events, such as flow convergences or regurgitant jets, using two-dimensional imaging ultrasound color flow Doppler systems may not be robust enough to characterize these spatially complex events. Methods. We studied two in vitro models using steady flow to optimize results. In the first constant-flow model, two different orifices were each mounted to produce flow convergences and free jets-a circular orifice and a rectangular orifice with orifice area of 0.24 cm2. In another flow model, steady flows through a circular orifice were directed toward a curved surrounding wall to produce wall adherent jets. Video composite data of color Doppler flow images from both free jet and wall jet models were reconstructed and analyzed after computer-controlled 180° rotational acquisition using a TomTec computer. Results. For the free jet model there was an excellent relation between actual flow rates and three-dimensional regurgitant jet volumes for both circular and rectangular orifices (r = 0.99 and r = 0.98, respectively). However, the rectangular orifice produced larger jet volumes than the circular orifice, even at the same flow rates (p <0.0001). Calculated flow rates by the hemispheric model using one axial measurement of the flow convergence isovelocity surface from two-dimensional color flow images underestimated actual flow rate by 35% for the circular orifice and by 44% for the rectangular orifice, whereas a hemielliptic method implemented using three axial measurements of the flow convergence zone derived using three-dimensional reconstruction correlated well with and underestimated actual flow rate to a lesser degree (22% for the circular orifice, 32% for the rectangular orifice). In the wall jet model, the jets were flattened against and spread along the wall and had reduced regurgitant jet volumes compared with free jets (p <0.01). Conclusions. Three-dimensional reconstruction of flow imaged by color Doppler may add quantitative spatial information to aid computation methods that have been used for evaluating valvular regurgitation, especially where they relate to complex geometric flow events.

UR - http://www.scopus.com/inward/record.url?scp=0030007148&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030007148&partnerID=8YFLogxK

U2 - 10.1016/0735-1097(96)00009-5

DO - 10.1016/0735-1097(96)00009-5

M3 - Article

C2 - 8626967

AN - SCOPUS:0030007148

VL - 27

SP - 1511

EP - 1518

JO - Journal of the American College of Cardiology

JF - Journal of the American College of Cardiology

SN - 0735-1097

IS - 6

ER -