The pansigmoidoscope: One year's experience in a gastrointestinal diagnostic unit

Ronald Katon, Clifford S. Melnyk

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Since May 1976, the Olympus pansigmoidoscope has been available for routine use at the University of Oregon Health Sciences Center. Two hundred sixty-five examinations were performed over the next year. The average distance examined was 49 cm. Time per examination ranged from 3 to 15 minutes, with an average of 8 minutes. Preparation consisted of one or two tap water enemas, except in known inflammatory bowel disease where no preparation was given. No patient received sedation and there were no complications. Small biopsy (2.8 mm), large biopsy (4.0 mm), “hot biopsy” and polypectomy were performed when indicated. The procedure was most helpful for the following indications: 1) differential diagnosis and follow-up of inflammatory bowel disease, 2) hematochezia, 3) evaluation of abnormal barium enema, 4) left-sided polypectomy, 5) diarrhea with normal barium enema, and 6) guaiac-positive stools. It was of no value in patients with abdominal pain with normal barium enema. Comparing the frequency of examinations this year with last year we found a 50% decrease in use of the rigid (25 cm) sigmoidoscope (538 to 270 exams) and a 98% decrease in use of the MB2 (100 cm) colonoscope (80 to 2 exams).

Original languageEnglish (US)
Pages (from-to)41-45
Number of pages5
JournalJournal of Clinical Gastroenterology
Volume1
Issue number1
StatePublished - 1979

Fingerprint

Biopsy
Sigmoidoscopes
Guaiac
Colonoscopes
Gastrointestinal Hemorrhage
Enema
Inflammatory Bowel Diseases
Abdominal Pain
Diarrhea
Differential Diagnosis
Water
Health
Barium Enema
Inflammatory Bowel Disease 2

ASJC Scopus subject areas

  • Gastroenterology

Cite this

The pansigmoidoscope : One year's experience in a gastrointestinal diagnostic unit. / Katon, Ronald; Melnyk, Clifford S.

In: Journal of Clinical Gastroenterology, Vol. 1, No. 1, 1979, p. 41-45.

Research output: Contribution to journalArticle

@article{58b7d13fc0664884944542bd46ada286,
title = "The pansigmoidoscope: One year's experience in a gastrointestinal diagnostic unit",
abstract = "Since May 1976, the Olympus pansigmoidoscope has been available for routine use at the University of Oregon Health Sciences Center. Two hundred sixty-five examinations were performed over the next year. The average distance examined was 49 cm. Time per examination ranged from 3 to 15 minutes, with an average of 8 minutes. Preparation consisted of one or two tap water enemas, except in known inflammatory bowel disease where no preparation was given. No patient received sedation and there were no complications. Small biopsy (2.8 mm), large biopsy (4.0 mm), “hot biopsy” and polypectomy were performed when indicated. The procedure was most helpful for the following indications: 1) differential diagnosis and follow-up of inflammatory bowel disease, 2) hematochezia, 3) evaluation of abnormal barium enema, 4) left-sided polypectomy, 5) diarrhea with normal barium enema, and 6) guaiac-positive stools. It was of no value in patients with abdominal pain with normal barium enema. Comparing the frequency of examinations this year with last year we found a 50{\%} decrease in use of the rigid (25 cm) sigmoidoscope (538 to 270 exams) and a 98{\%} decrease in use of the MB2 (100 cm) colonoscope (80 to 2 exams).",
author = "Ronald Katon and Melnyk, {Clifford S.}",
year = "1979",
language = "English (US)",
volume = "1",
pages = "41--45",
journal = "Journal of Clinical Gastroenterology",
issn = "0192-0790",
publisher = "Lippincott Williams and Wilkins",
number = "1",

}

TY - JOUR

T1 - The pansigmoidoscope

T2 - One year's experience in a gastrointestinal diagnostic unit

AU - Katon, Ronald

AU - Melnyk, Clifford S.

PY - 1979

Y1 - 1979

N2 - Since May 1976, the Olympus pansigmoidoscope has been available for routine use at the University of Oregon Health Sciences Center. Two hundred sixty-five examinations were performed over the next year. The average distance examined was 49 cm. Time per examination ranged from 3 to 15 minutes, with an average of 8 minutes. Preparation consisted of one or two tap water enemas, except in known inflammatory bowel disease where no preparation was given. No patient received sedation and there were no complications. Small biopsy (2.8 mm), large biopsy (4.0 mm), “hot biopsy” and polypectomy were performed when indicated. The procedure was most helpful for the following indications: 1) differential diagnosis and follow-up of inflammatory bowel disease, 2) hematochezia, 3) evaluation of abnormal barium enema, 4) left-sided polypectomy, 5) diarrhea with normal barium enema, and 6) guaiac-positive stools. It was of no value in patients with abdominal pain with normal barium enema. Comparing the frequency of examinations this year with last year we found a 50% decrease in use of the rigid (25 cm) sigmoidoscope (538 to 270 exams) and a 98% decrease in use of the MB2 (100 cm) colonoscope (80 to 2 exams).

AB - Since May 1976, the Olympus pansigmoidoscope has been available for routine use at the University of Oregon Health Sciences Center. Two hundred sixty-five examinations were performed over the next year. The average distance examined was 49 cm. Time per examination ranged from 3 to 15 minutes, with an average of 8 minutes. Preparation consisted of one or two tap water enemas, except in known inflammatory bowel disease where no preparation was given. No patient received sedation and there were no complications. Small biopsy (2.8 mm), large biopsy (4.0 mm), “hot biopsy” and polypectomy were performed when indicated. The procedure was most helpful for the following indications: 1) differential diagnosis and follow-up of inflammatory bowel disease, 2) hematochezia, 3) evaluation of abnormal barium enema, 4) left-sided polypectomy, 5) diarrhea with normal barium enema, and 6) guaiac-positive stools. It was of no value in patients with abdominal pain with normal barium enema. Comparing the frequency of examinations this year with last year we found a 50% decrease in use of the rigid (25 cm) sigmoidoscope (538 to 270 exams) and a 98% decrease in use of the MB2 (100 cm) colonoscope (80 to 2 exams).

UR - http://www.scopus.com/inward/record.url?scp=0018716475&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0018716475&partnerID=8YFLogxK

M3 - Article

C2 - 263129

AN - SCOPUS:0018716475

VL - 1

SP - 41

EP - 45

JO - Journal of Clinical Gastroenterology

JF - Journal of Clinical Gastroenterology

SN - 0192-0790

IS - 1

ER -