TY - JOUR
T1 - The James A. Rand Young Investigator's Award
T2 - Increased Revision Risk With Mobile Bearings in Total Knee Arthroplasty: An Analysis of the American Joint Replacement Registry
AU - Hegde, Vishal
AU - Kendall, Jamil
AU - Schabel, Kathryn
AU - Pelt, Christopher E.
AU - Yep, Patrick
AU - Mullen, Kyle
AU - De, Ayushmita
AU - Kagan, Ryland
N1 - Funding Information:
Funding: This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Publisher Copyright:
© 2023 Elsevier Inc.
PY - 2023
Y1 - 2023
N2 - Background: Mobile-bearing (MB) total knee arthroplasty (TKA) may reduce wear and improve patellar tracking but may increase revision risk due to tibial component design, balance complexity, and bearing dislocation. We utilized the American Joint Replacement Registry to examine risk of revision with MB compared to fixed-bearing (FB) designs. Methods: An analysis of primary TKA in patients over 65 years was performed with American Joint Replacement Registry data linked to Centers for Medicare and Medicaid Services data from 2012 to 2019. Analyses compared MB to FB designs with a subanalysis of implants from a single company. We identified 485,024 TKAs, with 452,199 (93.2%) FB-TKAs and 32,825 (6.8%) MB-TKAs. Cox proportional hazards regression modeling was used for all-cause revision and revision for infection, adjusting for sex, age, and competing risk of mortality. Event-free survival curves evaluated time to all-cause revision and revision for infection. Results: MB-TKAs were at an increased risk for all-cause revision: hazard ratio (HR) 1.36 ([95% confidence interval (CI) 1.24-1.49], P < .0001) but not revision for infection: HR 1.06 ([95% CI 0.90-1.25], P = .52). When comparing implants within a single company, MB-TKAs were at an increased risk of all-cause revision: HR 1.55 ([95% CI 1.38-1.73], P < .0001). Event-free survival curves demonstrated increased risk for all-cause revision for MB-TKA across all time points, with a greater magnitude of risk up to 8 years. Conclusion: Although survivorship of both designs was outstanding, MB-TKA designs demonstrated increased risk for all-cause revision. Additional investigation is needed to determine if this is related to patient selection factors, surgical technique, bearing, or implant design.
AB - Background: Mobile-bearing (MB) total knee arthroplasty (TKA) may reduce wear and improve patellar tracking but may increase revision risk due to tibial component design, balance complexity, and bearing dislocation. We utilized the American Joint Replacement Registry to examine risk of revision with MB compared to fixed-bearing (FB) designs. Methods: An analysis of primary TKA in patients over 65 years was performed with American Joint Replacement Registry data linked to Centers for Medicare and Medicaid Services data from 2012 to 2019. Analyses compared MB to FB designs with a subanalysis of implants from a single company. We identified 485,024 TKAs, with 452,199 (93.2%) FB-TKAs and 32,825 (6.8%) MB-TKAs. Cox proportional hazards regression modeling was used for all-cause revision and revision for infection, adjusting for sex, age, and competing risk of mortality. Event-free survival curves evaluated time to all-cause revision and revision for infection. Results: MB-TKAs were at an increased risk for all-cause revision: hazard ratio (HR) 1.36 ([95% confidence interval (CI) 1.24-1.49], P < .0001) but not revision for infection: HR 1.06 ([95% CI 0.90-1.25], P = .52). When comparing implants within a single company, MB-TKAs were at an increased risk of all-cause revision: HR 1.55 ([95% CI 1.38-1.73], P < .0001). Event-free survival curves demonstrated increased risk for all-cause revision for MB-TKA across all time points, with a greater magnitude of risk up to 8 years. Conclusion: Although survivorship of both designs was outstanding, MB-TKA designs demonstrated increased risk for all-cause revision. Additional investigation is needed to determine if this is related to patient selection factors, surgical technique, bearing, or implant design.
KW - American joint replacement registry
KW - mobile bearing
KW - revision total knee arthroplasty
KW - rotating platform
KW - total knee arthroplasty
UR - http://www.scopus.com/inward/record.url?scp=85146533809&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85146533809&partnerID=8YFLogxK
U2 - 10.1016/j.arth.2023.01.007
DO - 10.1016/j.arth.2023.01.007
M3 - Article
C2 - 36639116
AN - SCOPUS:85146533809
SN - 0883-5403
JO - Journal of Arthroplasty
JF - Journal of Arthroplasty