Test-retest reliability in EEG frequency analysis

Research output: Contribution to journalArticle

145 Citations (Scopus)

Abstract

This study was performed to gain a better understanding of EEG frequency analysis test-retest reliability in normal healthy adults, and to evaluate factors which could influence the measured inter-record differences. Nineteen subjects underwent serial EEG recordings at 5 min and 12-16 week intervals. Records were visually edited using a standardized protocol, and FFT frequency analysis performed on segments of 60, 40, or 20 sec total length. Correlation coefficients for broad band features averaged 0.92 over the 5 min retest interval and 0.84 over the 12-16 week interval. There was essentially no difference between correlation coefficients of absolute and relative power features. Coefficients based on 60 sec records were marginally higher than those of 40 or 20 sec records. On the other hand, test-retest percent differences were typically lower for relative as opposed to absolute power features, and 60 sec records showed consistently lower percent differences than did 40 or particularly 20 sec records. Peak alpha frequency and mean frequency were the most stable EEG features at either interval. Montage had significant effects on test-retest differences at the 12-16 week interval. A significant association between intra-record and inter-record variability could not be demonstrated.

Original languageEnglish (US)
Pages (from-to)382-392
Number of pages11
JournalElectroencephalography and Clinical Neurophysiology
Volume79
Issue number5
DOIs
StatePublished - 1991

Fingerprint

Reproducibility of Results
Electroencephalography

Keywords

  • EEG frequency analysis
  • Test-retest reliability

ASJC Scopus subject areas

  • Clinical Neurology
  • Neuroscience(all)

Cite this

Test-retest reliability in EEG frequency analysis. / Salinsky, Martin; Oken, Barry; Morehead, L.

In: Electroencephalography and Clinical Neurophysiology, Vol. 79, No. 5, 1991, p. 382-392.

Research output: Contribution to journalArticle

@article{ae88faa08a554f378c0930131fa01852,
title = "Test-retest reliability in EEG frequency analysis",
abstract = "This study was performed to gain a better understanding of EEG frequency analysis test-retest reliability in normal healthy adults, and to evaluate factors which could influence the measured inter-record differences. Nineteen subjects underwent serial EEG recordings at 5 min and 12-16 week intervals. Records were visually edited using a standardized protocol, and FFT frequency analysis performed on segments of 60, 40, or 20 sec total length. Correlation coefficients for broad band features averaged 0.92 over the 5 min retest interval and 0.84 over the 12-16 week interval. There was essentially no difference between correlation coefficients of absolute and relative power features. Coefficients based on 60 sec records were marginally higher than those of 40 or 20 sec records. On the other hand, test-retest percent differences were typically lower for relative as opposed to absolute power features, and 60 sec records showed consistently lower percent differences than did 40 or particularly 20 sec records. Peak alpha frequency and mean frequency were the most stable EEG features at either interval. Montage had significant effects on test-retest differences at the 12-16 week interval. A significant association between intra-record and inter-record variability could not be demonstrated.",
keywords = "EEG frequency analysis, Test-retest reliability",
author = "Martin Salinsky and Barry Oken and L. Morehead",
year = "1991",
doi = "10.1016/0013-4694(91)90203-G",
language = "English (US)",
volume = "79",
pages = "382--392",
journal = "Electroencephalography and Clinical Neurophysiology",
issn = "0013-4694",
publisher = "Elsevier BV",
number = "5",

}

TY - JOUR

T1 - Test-retest reliability in EEG frequency analysis

AU - Salinsky, Martin

AU - Oken, Barry

AU - Morehead, L.

PY - 1991

Y1 - 1991

N2 - This study was performed to gain a better understanding of EEG frequency analysis test-retest reliability in normal healthy adults, and to evaluate factors which could influence the measured inter-record differences. Nineteen subjects underwent serial EEG recordings at 5 min and 12-16 week intervals. Records were visually edited using a standardized protocol, and FFT frequency analysis performed on segments of 60, 40, or 20 sec total length. Correlation coefficients for broad band features averaged 0.92 over the 5 min retest interval and 0.84 over the 12-16 week interval. There was essentially no difference between correlation coefficients of absolute and relative power features. Coefficients based on 60 sec records were marginally higher than those of 40 or 20 sec records. On the other hand, test-retest percent differences were typically lower for relative as opposed to absolute power features, and 60 sec records showed consistently lower percent differences than did 40 or particularly 20 sec records. Peak alpha frequency and mean frequency were the most stable EEG features at either interval. Montage had significant effects on test-retest differences at the 12-16 week interval. A significant association between intra-record and inter-record variability could not be demonstrated.

AB - This study was performed to gain a better understanding of EEG frequency analysis test-retest reliability in normal healthy adults, and to evaluate factors which could influence the measured inter-record differences. Nineteen subjects underwent serial EEG recordings at 5 min and 12-16 week intervals. Records were visually edited using a standardized protocol, and FFT frequency analysis performed on segments of 60, 40, or 20 sec total length. Correlation coefficients for broad band features averaged 0.92 over the 5 min retest interval and 0.84 over the 12-16 week interval. There was essentially no difference between correlation coefficients of absolute and relative power features. Coefficients based on 60 sec records were marginally higher than those of 40 or 20 sec records. On the other hand, test-retest percent differences were typically lower for relative as opposed to absolute power features, and 60 sec records showed consistently lower percent differences than did 40 or particularly 20 sec records. Peak alpha frequency and mean frequency were the most stable EEG features at either interval. Montage had significant effects on test-retest differences at the 12-16 week interval. A significant association between intra-record and inter-record variability could not be demonstrated.

KW - EEG frequency analysis

KW - Test-retest reliability

UR - http://www.scopus.com/inward/record.url?scp=0025990956&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025990956&partnerID=8YFLogxK

U2 - 10.1016/0013-4694(91)90203-G

DO - 10.1016/0013-4694(91)90203-G

M3 - Article

VL - 79

SP - 382

EP - 392

JO - Electroencephalography and Clinical Neurophysiology

JF - Electroencephalography and Clinical Neurophysiology

SN - 0013-4694

IS - 5

ER -