Template-Driven Computed Tomography Radiation Dose Reporting. Implementation of a Radiology Housestaff Quality Improvement Project

John Paul J Yu, Akash P. Kansagra, David M. Naeger, Robert G. Gould, Fergus Coakley

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Rationale and Objectives: Radiation exposure from medical imaging has received increasing attention in recent years. Ongoing calls to report radiation doses received during radiology studies as a means of recording cumulative exposure and identifying rare over-exposures have culminated in the State of California passing a mandatory reporting requirement effective July 1, 2012. Herein we describe a radiology housestaff-led quality improvement project to track radiation dose reporting a full year prior to state reporting mandates using a template-driven reporting system and our results over the first 12 months of its implementation. Materials and Methods: Effective July 2011, all radiology trainees were instructed to use a standard computed tomography (CT) report template that included a CT dose measurement derived from dose information routinely displayed on our picture archiving and communication system. Consecutive reports from July 1, 2011, to June 30, 2012, of patients who underwent CT examinations at our institution were then retrospectively reviewed. Compliance of each study with the reporting requirement was assessed based on the presence or absence of a radiation dose statement within the finalized report. Results: A total of 36,217 eligible consecutive CT reports were identified within the review period. Of these, 91.9% reported the radiation dose for the examination, greatly exceeding the initial goal of 80% compliance with the dose reporting requirement. Conclusion: Successful reporting of CT radiation doses resulted from template-driven reporting, readily accessible calculation tools to facilitate dose calculation, and minimization of reporting burden on the radiologist a full year prior to state regulatory mandates.

Original languageEnglish (US)
Pages (from-to)769-772
Number of pages4
JournalAcademic Radiology
Volume20
Issue number6
DOIs
StatePublished - Jun 2013

Fingerprint

Quality Improvement
Radiology
Tomography
Radiation
Mandatory Reporting
Radiology Information Systems
Diagnostic Imaging
Compliance

Keywords

  • Computed tomography
  • Dose reporting
  • Quality improvement

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Template-Driven Computed Tomography Radiation Dose Reporting. Implementation of a Radiology Housestaff Quality Improvement Project. / Yu, John Paul J; Kansagra, Akash P.; Naeger, David M.; Gould, Robert G.; Coakley, Fergus.

In: Academic Radiology, Vol. 20, No. 6, 06.2013, p. 769-772.

Research output: Contribution to journalArticle

Yu, John Paul J ; Kansagra, Akash P. ; Naeger, David M. ; Gould, Robert G. ; Coakley, Fergus. / Template-Driven Computed Tomography Radiation Dose Reporting. Implementation of a Radiology Housestaff Quality Improvement Project. In: Academic Radiology. 2013 ; Vol. 20, No. 6. pp. 769-772.
@article{997f55c3660146c4993ee4a52b708ade,
title = "Template-Driven Computed Tomography Radiation Dose Reporting. Implementation of a Radiology Housestaff Quality Improvement Project",
abstract = "Rationale and Objectives: Radiation exposure from medical imaging has received increasing attention in recent years. Ongoing calls to report radiation doses received during radiology studies as a means of recording cumulative exposure and identifying rare over-exposures have culminated in the State of California passing a mandatory reporting requirement effective July 1, 2012. Herein we describe a radiology housestaff-led quality improvement project to track radiation dose reporting a full year prior to state reporting mandates using a template-driven reporting system and our results over the first 12 months of its implementation. Materials and Methods: Effective July 2011, all radiology trainees were instructed to use a standard computed tomography (CT) report template that included a CT dose measurement derived from dose information routinely displayed on our picture archiving and communication system. Consecutive reports from July 1, 2011, to June 30, 2012, of patients who underwent CT examinations at our institution were then retrospectively reviewed. Compliance of each study with the reporting requirement was assessed based on the presence or absence of a radiation dose statement within the finalized report. Results: A total of 36,217 eligible consecutive CT reports were identified within the review period. Of these, 91.9{\%} reported the radiation dose for the examination, greatly exceeding the initial goal of 80{\%} compliance with the dose reporting requirement. Conclusion: Successful reporting of CT radiation doses resulted from template-driven reporting, readily accessible calculation tools to facilitate dose calculation, and minimization of reporting burden on the radiologist a full year prior to state regulatory mandates.",
keywords = "Computed tomography, Dose reporting, Quality improvement",
author = "Yu, {John Paul J} and Kansagra, {Akash P.} and Naeger, {David M.} and Gould, {Robert G.} and Fergus Coakley",
year = "2013",
month = "6",
doi = "10.1016/j.acra.2012.11.005",
language = "English (US)",
volume = "20",
pages = "769--772",
journal = "Academic Radiology",
issn = "1076-6332",
publisher = "Elsevier USA",
number = "6",

}

TY - JOUR

T1 - Template-Driven Computed Tomography Radiation Dose Reporting. Implementation of a Radiology Housestaff Quality Improvement Project

AU - Yu, John Paul J

AU - Kansagra, Akash P.

AU - Naeger, David M.

AU - Gould, Robert G.

AU - Coakley, Fergus

PY - 2013/6

Y1 - 2013/6

N2 - Rationale and Objectives: Radiation exposure from medical imaging has received increasing attention in recent years. Ongoing calls to report radiation doses received during radiology studies as a means of recording cumulative exposure and identifying rare over-exposures have culminated in the State of California passing a mandatory reporting requirement effective July 1, 2012. Herein we describe a radiology housestaff-led quality improvement project to track radiation dose reporting a full year prior to state reporting mandates using a template-driven reporting system and our results over the first 12 months of its implementation. Materials and Methods: Effective July 2011, all radiology trainees were instructed to use a standard computed tomography (CT) report template that included a CT dose measurement derived from dose information routinely displayed on our picture archiving and communication system. Consecutive reports from July 1, 2011, to June 30, 2012, of patients who underwent CT examinations at our institution were then retrospectively reviewed. Compliance of each study with the reporting requirement was assessed based on the presence or absence of a radiation dose statement within the finalized report. Results: A total of 36,217 eligible consecutive CT reports were identified within the review period. Of these, 91.9% reported the radiation dose for the examination, greatly exceeding the initial goal of 80% compliance with the dose reporting requirement. Conclusion: Successful reporting of CT radiation doses resulted from template-driven reporting, readily accessible calculation tools to facilitate dose calculation, and minimization of reporting burden on the radiologist a full year prior to state regulatory mandates.

AB - Rationale and Objectives: Radiation exposure from medical imaging has received increasing attention in recent years. Ongoing calls to report radiation doses received during radiology studies as a means of recording cumulative exposure and identifying rare over-exposures have culminated in the State of California passing a mandatory reporting requirement effective July 1, 2012. Herein we describe a radiology housestaff-led quality improvement project to track radiation dose reporting a full year prior to state reporting mandates using a template-driven reporting system and our results over the first 12 months of its implementation. Materials and Methods: Effective July 2011, all radiology trainees were instructed to use a standard computed tomography (CT) report template that included a CT dose measurement derived from dose information routinely displayed on our picture archiving and communication system. Consecutive reports from July 1, 2011, to June 30, 2012, of patients who underwent CT examinations at our institution were then retrospectively reviewed. Compliance of each study with the reporting requirement was assessed based on the presence or absence of a radiation dose statement within the finalized report. Results: A total of 36,217 eligible consecutive CT reports were identified within the review period. Of these, 91.9% reported the radiation dose for the examination, greatly exceeding the initial goal of 80% compliance with the dose reporting requirement. Conclusion: Successful reporting of CT radiation doses resulted from template-driven reporting, readily accessible calculation tools to facilitate dose calculation, and minimization of reporting burden on the radiologist a full year prior to state regulatory mandates.

KW - Computed tomography

KW - Dose reporting

KW - Quality improvement

UR - http://www.scopus.com/inward/record.url?scp=84877325258&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84877325258&partnerID=8YFLogxK

U2 - 10.1016/j.acra.2012.11.005

DO - 10.1016/j.acra.2012.11.005

M3 - Article

VL - 20

SP - 769

EP - 772

JO - Academic Radiology

JF - Academic Radiology

SN - 1076-6332

IS - 6

ER -