TY - JOUR
T1 - Simultaneous measurement of multiple ear proteins with multiplex ELISA assays
AU - Trune, Dennis R.
AU - Larrain, Barbara E.
AU - Hausman, Frances A.
AU - Kempton, J. Beth
AU - MacArthur, Carol J.
N1 - Funding Information:
The authors thank Ms. Paige Kruger for assistance in the ELISA technique. Research supported by NIH-NIDCD R01 DC009455 and R01 DC005593 (DRT).
PY - 2011/5
Y1 - 2011/5
N2 - A recent advancement in enzyme-linked immunosorbent assay (ELISA) technology is the multiplex antibody array that measures multiple proteins simultaneously within a single sample. This allows reduction in sample volume, time, labor, and material costs, while increasing sensitivity over single ELISA. Current multiplex platforms include planar-based systems using microplates or slides, or bead-based suspension assay with microspheres. To determine the applicability of this technology for ear research, we used 3 different multiplex ELISA-based immunoassay arrays from 4 different companies to measure cytokine levels in mouse middle and inner ear tissue lysate extracts 24 h following transtympanic Haemophilus influenzae inoculation. Middle and inner ear tissue lysates were analyzed using testing services from Quansys Biosciences, Aushon Biosystems SearchLight (both microplate-based), MILLIPLEX MAP Sample (bead-based), and a RayBiotech, Inc (slide-based) kit. Samples were assayed in duplicate or triplicate. Results were compared to determine their relative sensitivity and reliability for measures of cytokines related to inflammation. The cytokine pg/ml amounts varied among the multiplex assays, so a comparison also was made of the mean fold increase in cytokines from untreated controls. Several cytokines and chemokines were elevated, the extent dependent upon the assay sensitivity. Those most significantly elevated were IL-1α, IL-1β, IL-6, TNFα, VEGF, and IL-8/MIP-2. The results of the multiplex systems were compared with single ELISA kits (IL-1β, IL-6) to assess sensitivity over the traditional method. Overall, the Quansys Biosciences and SearchLight arrays showed the greatest sensitivity, both employing the same multiplex methodology of a spotted array within a microplate well with chemiluminescent detection. They also were more sensitive than the traditional single ELISA performed with commercial kits and matched gene expression changes determined by quantitative RT-PCR. The Quansys array showed a limit of detection for ear IL-6 down to 2-4 pg/ml, indicating it is sufficiently sensitive to detect ear proteins present in low concentrations. Thus, the multiplex ELISA procedures appear suitable and reliable for the study of hearing related proteins, providing accurate, quantitative, reproducible results with considerable improvement in sensitivity and economy.
AB - A recent advancement in enzyme-linked immunosorbent assay (ELISA) technology is the multiplex antibody array that measures multiple proteins simultaneously within a single sample. This allows reduction in sample volume, time, labor, and material costs, while increasing sensitivity over single ELISA. Current multiplex platforms include planar-based systems using microplates or slides, or bead-based suspension assay with microspheres. To determine the applicability of this technology for ear research, we used 3 different multiplex ELISA-based immunoassay arrays from 4 different companies to measure cytokine levels in mouse middle and inner ear tissue lysate extracts 24 h following transtympanic Haemophilus influenzae inoculation. Middle and inner ear tissue lysates were analyzed using testing services from Quansys Biosciences, Aushon Biosystems SearchLight (both microplate-based), MILLIPLEX MAP Sample (bead-based), and a RayBiotech, Inc (slide-based) kit. Samples were assayed in duplicate or triplicate. Results were compared to determine their relative sensitivity and reliability for measures of cytokines related to inflammation. The cytokine pg/ml amounts varied among the multiplex assays, so a comparison also was made of the mean fold increase in cytokines from untreated controls. Several cytokines and chemokines were elevated, the extent dependent upon the assay sensitivity. Those most significantly elevated were IL-1α, IL-1β, IL-6, TNFα, VEGF, and IL-8/MIP-2. The results of the multiplex systems were compared with single ELISA kits (IL-1β, IL-6) to assess sensitivity over the traditional method. Overall, the Quansys Biosciences and SearchLight arrays showed the greatest sensitivity, both employing the same multiplex methodology of a spotted array within a microplate well with chemiluminescent detection. They also were more sensitive than the traditional single ELISA performed with commercial kits and matched gene expression changes determined by quantitative RT-PCR. The Quansys array showed a limit of detection for ear IL-6 down to 2-4 pg/ml, indicating it is sufficiently sensitive to detect ear proteins present in low concentrations. Thus, the multiplex ELISA procedures appear suitable and reliable for the study of hearing related proteins, providing accurate, quantitative, reproducible results with considerable improvement in sensitivity and economy.
UR - http://www.scopus.com/inward/record.url?scp=79955963084&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79955963084&partnerID=8YFLogxK
U2 - 10.1016/j.heares.2010.11.009
DO - 10.1016/j.heares.2010.11.009
M3 - Article
C2 - 21144888
AN - SCOPUS:79955963084
SN - 0378-5955
VL - 275
SP - 1
EP - 7
JO - Hearing Research
JF - Hearing Research
IS - 1-2
ER -