One hundred asymptomatic high-risk renal transplant candidates were screened for asymptomatic coronary artery disease using stress cardiac isotopic imaging. The cardiac markers, serum cTnT, cTnI, and CKMB, were collected pre and post stress testing. Of the 99 patients whose cardiac scans were technically satisfactory, 32 were normal, 49 had a definite imaging abnormality and the scan was indeterminate in the remaining 18 patients. Based on these results, patients were stratified into either normal, indeterminate or abnormal scan groups. They then were analyzed to detect any correlations between cardiac perfusion defects and either elevated pre-stress cardiac markers or consistent changes 24 h after stress testing. While the mean pre-stress serum values for both cardiac troponin T (0.117 ± 0.12 μg/L) and cardiac troponin I (0.235 ± 0.89 μg/L) were increased in the abnormal cardiac scan group, only the cTnT value proved to differ significantly from the normal group (p <0.01). For the indeterminate group neither marker was different from the normal scan group. Only an elevated serum cTnT > 0.1 μg/L (OR 3.042, p = 0.030) proved to discriminate an abnormal scan in this population. It is concluded that the increase in pre-stress serum cTnT encountered in patients with chronic renal failure, with or without evidence of overt, symptomatic coronary artery disease, may represent a combination of subclinical myocardial damage and a prolonged half-life of the marker in the serum. Because of the frequency of elevated serum concentrations of cTnT and, to a lesser degree cTnI, the physician should exercise caution when interpreting a single elevated Troponin value during the evaluation of chest pain in patients with end-stage renal disease. A cTnT > 0.1 μg/L increases the likelihood of finding significant coronary artery disease three fold in high-risk ESRD patients being evaluated for renal transplantation.

Original languageEnglish (US)
Pages (from-to)55-65
Number of pages11
JournalRenal Failure
Volume25
Issue number1
DOIs
StatePublished - 2003

Fingerprint

Troponin
Chronic Kidney Failure
Serum
Coronary Artery Disease
Biomarkers
Troponin T
Troponin I
Chest Pain
Kidney Transplantation
Half-Life
Perfusion
Exercise
Physicians
Transplants
Kidney
Population

Keywords

  • Cardiac markers
  • ESRD
  • Pre-transplant evaluation
  • Stress testing
  • Troponins

ASJC Scopus subject areas

  • Nephrology

Cite this

Relationship between elevated serum Troponin values in end-stage renal disease patients and abnormal isotopic cardiac scans following stress. / Porter, George A.; Norton, Theadore L.; Lindsley, Jessie; Stevens, Jeffrey; Phillips, David S.; Bennett, William M.

In: Renal Failure, Vol. 25, No. 1, 2003, p. 55-65.

Research output: Contribution to journalArticle

Porter, George A. ; Norton, Theadore L. ; Lindsley, Jessie ; Stevens, Jeffrey ; Phillips, David S. ; Bennett, William M. / Relationship between elevated serum Troponin values in end-stage renal disease patients and abnormal isotopic cardiac scans following stress. In: Renal Failure. 2003 ; Vol. 25, No. 1. pp. 55-65.
@article{f0328afe19464a5dbfb670de94c93fed,
title = "Relationship between elevated serum Troponin values in end-stage renal disease patients and abnormal isotopic cardiac scans following stress",
abstract = "One hundred asymptomatic high-risk renal transplant candidates were screened for asymptomatic coronary artery disease using stress cardiac isotopic imaging. The cardiac markers, serum cTnT, cTnI, and CKMB, were collected pre and post stress testing. Of the 99 patients whose cardiac scans were technically satisfactory, 32 were normal, 49 had a definite imaging abnormality and the scan was indeterminate in the remaining 18 patients. Based on these results, patients were stratified into either normal, indeterminate or abnormal scan groups. They then were analyzed to detect any correlations between cardiac perfusion defects and either elevated pre-stress cardiac markers or consistent changes 24 h after stress testing. While the mean pre-stress serum values for both cardiac troponin T (0.117 ± 0.12 μg/L) and cardiac troponin I (0.235 ± 0.89 μg/L) were increased in the abnormal cardiac scan group, only the cTnT value proved to differ significantly from the normal group (p <0.01). For the indeterminate group neither marker was different from the normal scan group. Only an elevated serum cTnT > 0.1 μg/L (OR 3.042, p = 0.030) proved to discriminate an abnormal scan in this population. It is concluded that the increase in pre-stress serum cTnT encountered in patients with chronic renal failure, with or without evidence of overt, symptomatic coronary artery disease, may represent a combination of subclinical myocardial damage and a prolonged half-life of the marker in the serum. Because of the frequency of elevated serum concentrations of cTnT and, to a lesser degree cTnI, the physician should exercise caution when interpreting a single elevated Troponin value during the evaluation of chest pain in patients with end-stage renal disease. A cTnT > 0.1 μg/L increases the likelihood of finding significant coronary artery disease three fold in high-risk ESRD patients being evaluated for renal transplantation.",
keywords = "Cardiac markers, ESRD, Pre-transplant evaluation, Stress testing, Troponins",
author = "Porter, {George A.} and Norton, {Theadore L.} and Jessie Lindsley and Jeffrey Stevens and Phillips, {David S.} and Bennett, {William M.}",
year = "2003",
doi = "10.1081/JDI-120017468",
language = "English (US)",
volume = "25",
pages = "55--65",
journal = "Renal Failure",
issn = "0886-022X",
publisher = "Informa Healthcare",
number = "1",

}

TY - JOUR

T1 - Relationship between elevated serum Troponin values in end-stage renal disease patients and abnormal isotopic cardiac scans following stress

AU - Porter, George A.

AU - Norton, Theadore L.

AU - Lindsley, Jessie

AU - Stevens, Jeffrey

AU - Phillips, David S.

AU - Bennett, William M.

PY - 2003

Y1 - 2003

N2 - One hundred asymptomatic high-risk renal transplant candidates were screened for asymptomatic coronary artery disease using stress cardiac isotopic imaging. The cardiac markers, serum cTnT, cTnI, and CKMB, were collected pre and post stress testing. Of the 99 patients whose cardiac scans were technically satisfactory, 32 were normal, 49 had a definite imaging abnormality and the scan was indeterminate in the remaining 18 patients. Based on these results, patients were stratified into either normal, indeterminate or abnormal scan groups. They then were analyzed to detect any correlations between cardiac perfusion defects and either elevated pre-stress cardiac markers or consistent changes 24 h after stress testing. While the mean pre-stress serum values for both cardiac troponin T (0.117 ± 0.12 μg/L) and cardiac troponin I (0.235 ± 0.89 μg/L) were increased in the abnormal cardiac scan group, only the cTnT value proved to differ significantly from the normal group (p <0.01). For the indeterminate group neither marker was different from the normal scan group. Only an elevated serum cTnT > 0.1 μg/L (OR 3.042, p = 0.030) proved to discriminate an abnormal scan in this population. It is concluded that the increase in pre-stress serum cTnT encountered in patients with chronic renal failure, with or without evidence of overt, symptomatic coronary artery disease, may represent a combination of subclinical myocardial damage and a prolonged half-life of the marker in the serum. Because of the frequency of elevated serum concentrations of cTnT and, to a lesser degree cTnI, the physician should exercise caution when interpreting a single elevated Troponin value during the evaluation of chest pain in patients with end-stage renal disease. A cTnT > 0.1 μg/L increases the likelihood of finding significant coronary artery disease three fold in high-risk ESRD patients being evaluated for renal transplantation.

AB - One hundred asymptomatic high-risk renal transplant candidates were screened for asymptomatic coronary artery disease using stress cardiac isotopic imaging. The cardiac markers, serum cTnT, cTnI, and CKMB, were collected pre and post stress testing. Of the 99 patients whose cardiac scans were technically satisfactory, 32 were normal, 49 had a definite imaging abnormality and the scan was indeterminate in the remaining 18 patients. Based on these results, patients were stratified into either normal, indeterminate or abnormal scan groups. They then were analyzed to detect any correlations between cardiac perfusion defects and either elevated pre-stress cardiac markers or consistent changes 24 h after stress testing. While the mean pre-stress serum values for both cardiac troponin T (0.117 ± 0.12 μg/L) and cardiac troponin I (0.235 ± 0.89 μg/L) were increased in the abnormal cardiac scan group, only the cTnT value proved to differ significantly from the normal group (p <0.01). For the indeterminate group neither marker was different from the normal scan group. Only an elevated serum cTnT > 0.1 μg/L (OR 3.042, p = 0.030) proved to discriminate an abnormal scan in this population. It is concluded that the increase in pre-stress serum cTnT encountered in patients with chronic renal failure, with or without evidence of overt, symptomatic coronary artery disease, may represent a combination of subclinical myocardial damage and a prolonged half-life of the marker in the serum. Because of the frequency of elevated serum concentrations of cTnT and, to a lesser degree cTnI, the physician should exercise caution when interpreting a single elevated Troponin value during the evaluation of chest pain in patients with end-stage renal disease. A cTnT > 0.1 μg/L increases the likelihood of finding significant coronary artery disease three fold in high-risk ESRD patients being evaluated for renal transplantation.

KW - Cardiac markers

KW - ESRD

KW - Pre-transplant evaluation

KW - Stress testing

KW - Troponins

UR - http://www.scopus.com/inward/record.url?scp=0037286458&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0037286458&partnerID=8YFLogxK

U2 - 10.1081/JDI-120017468

DO - 10.1081/JDI-120017468

M3 - Article

C2 - 12617333

AN - SCOPUS:0037286458

VL - 25

SP - 55

EP - 65

JO - Renal Failure

JF - Renal Failure

SN - 0886-022X

IS - 1

ER -