Region-Specific Deflection Responses of WorldSID and ES2-re Devices in Pure Lateral and Oblique Side Impacts

Narayan Yoganandan, John R. Humm, Frank A. Pintar, Karen Brasel

Research output: Contribution to journalConference article

Abstract

The objective of this study was to determine region-specific deflection responses of the WorldSID and ES2-re devices under pure lateral and oblique side impact loading. A modular, anthropometry-specific load wall was used. It consisted of the Shoulder, Thorax, Abdomen, superior Pelvis, and inferior Pelvis plates, termed the STAPP load wall design. The two devices were positioned upright on the platform of a bench seat, and sled tests were conducted at 3.4, 6.7, and 7.5 m/s. Two chestbands were used on each dummy at the thoracic and abdominal regions. Internal sensors were also used. Effective peak deflections were obtained from the chestband contours. Based on the preselected lateral-most point/location on the pretest contour, "internal sensor-type" peak deflections were also obtained using chestband contours. In addition, peak deflection data were obtained from internal sensor records. In oblique tests, the mean "IR-TRACC-type" peak deflections in the WorldSID device were 40 to 80% of effective peak deflections, whereas the mean "potentiometer-type" peak deflections in the ES2-device were 7 to 50%. The WorldSID device appears to better mimic region-specific responses to oblique loading than the ES2-re device, likely due to the differences in its design of the thoracic and abdominal regions. While the lateral-most point corresponding to the current 1D IR-TRACC location was found to replicate the pure lateral response, it was found to be less than optimal to track oblique loading. Although a laterally positioned sensor provides lower peak deflections in oblique loading, the addition of an angle-measuring sensor should allow modulating the translational metric for this mode. From this perspective, it may be worthwhile to use a 2D IR-TRACC or an optical sensor to verify these findings without chestband measures. Such an analysis has the potential to modify thoracic and abdominal injury criteria to account for obliqueness.

Original languageEnglish (US)
JournalSAE Technical Papers
Volume2011-November
Issue numberNovember
DOIs
StatePublished - Nov 7 2011
Externally publishedYes
Event55th SAE Stapp Car Crash Conference, STAPP 2011 - Dearborn, United States
Duration: Nov 7 2011Nov 9 2011

Fingerprint

Sensors
Anthropometry
Optical sensors
Seats

Keywords

  • Biomechanics
  • Crash test dummy
  • Deflection
  • Injury metric
  • Lateral impact
  • Oblique loading
  • Sled test

ASJC Scopus subject areas

  • Automotive Engineering
  • Safety, Risk, Reliability and Quality
  • Pollution
  • Industrial and Manufacturing Engineering

Cite this

Region-Specific Deflection Responses of WorldSID and ES2-re Devices in Pure Lateral and Oblique Side Impacts. / Yoganandan, Narayan; Humm, John R.; Pintar, Frank A.; Brasel, Karen.

In: SAE Technical Papers, Vol. 2011-November, No. November, 07.11.2011.

Research output: Contribution to journalConference article

Yoganandan, Narayan ; Humm, John R. ; Pintar, Frank A. ; Brasel, Karen. / Region-Specific Deflection Responses of WorldSID and ES2-re Devices in Pure Lateral and Oblique Side Impacts. In: SAE Technical Papers. 2011 ; Vol. 2011-November, No. November.
@article{59aee67959494f9aaba7294667d6655f,
title = "Region-Specific Deflection Responses of WorldSID and ES2-re Devices in Pure Lateral and Oblique Side Impacts",
abstract = "The objective of this study was to determine region-specific deflection responses of the WorldSID and ES2-re devices under pure lateral and oblique side impact loading. A modular, anthropometry-specific load wall was used. It consisted of the Shoulder, Thorax, Abdomen, superior Pelvis, and inferior Pelvis plates, termed the STAPP load wall design. The two devices were positioned upright on the platform of a bench seat, and sled tests were conducted at 3.4, 6.7, and 7.5 m/s. Two chestbands were used on each dummy at the thoracic and abdominal regions. Internal sensors were also used. Effective peak deflections were obtained from the chestband contours. Based on the preselected lateral-most point/location on the pretest contour, {"}internal sensor-type{"} peak deflections were also obtained using chestband contours. In addition, peak deflection data were obtained from internal sensor records. In oblique tests, the mean {"}IR-TRACC-type{"} peak deflections in the WorldSID device were 40 to 80{\%} of effective peak deflections, whereas the mean {"}potentiometer-type{"} peak deflections in the ES2-device were 7 to 50{\%}. The WorldSID device appears to better mimic region-specific responses to oblique loading than the ES2-re device, likely due to the differences in its design of the thoracic and abdominal regions. While the lateral-most point corresponding to the current 1D IR-TRACC location was found to replicate the pure lateral response, it was found to be less than optimal to track oblique loading. Although a laterally positioned sensor provides lower peak deflections in oblique loading, the addition of an angle-measuring sensor should allow modulating the translational metric for this mode. From this perspective, it may be worthwhile to use a 2D IR-TRACC or an optical sensor to verify these findings without chestband measures. Such an analysis has the potential to modify thoracic and abdominal injury criteria to account for obliqueness.",
keywords = "Biomechanics, Crash test dummy, Deflection, Injury metric, Lateral impact, Oblique loading, Sled test",
author = "Narayan Yoganandan and Humm, {John R.} and Pintar, {Frank A.} and Karen Brasel",
year = "2011",
month = "11",
day = "7",
doi = "10.4271/2011-22-0013",
language = "English (US)",
volume = "2011-November",
journal = "SAE Technical Papers",
issn = "0148-7191",
publisher = "SAE International",
number = "November",

}

TY - JOUR

T1 - Region-Specific Deflection Responses of WorldSID and ES2-re Devices in Pure Lateral and Oblique Side Impacts

AU - Yoganandan, Narayan

AU - Humm, John R.

AU - Pintar, Frank A.

AU - Brasel, Karen

PY - 2011/11/7

Y1 - 2011/11/7

N2 - The objective of this study was to determine region-specific deflection responses of the WorldSID and ES2-re devices under pure lateral and oblique side impact loading. A modular, anthropometry-specific load wall was used. It consisted of the Shoulder, Thorax, Abdomen, superior Pelvis, and inferior Pelvis plates, termed the STAPP load wall design. The two devices were positioned upright on the platform of a bench seat, and sled tests were conducted at 3.4, 6.7, and 7.5 m/s. Two chestbands were used on each dummy at the thoracic and abdominal regions. Internal sensors were also used. Effective peak deflections were obtained from the chestband contours. Based on the preselected lateral-most point/location on the pretest contour, "internal sensor-type" peak deflections were also obtained using chestband contours. In addition, peak deflection data were obtained from internal sensor records. In oblique tests, the mean "IR-TRACC-type" peak deflections in the WorldSID device were 40 to 80% of effective peak deflections, whereas the mean "potentiometer-type" peak deflections in the ES2-device were 7 to 50%. The WorldSID device appears to better mimic region-specific responses to oblique loading than the ES2-re device, likely due to the differences in its design of the thoracic and abdominal regions. While the lateral-most point corresponding to the current 1D IR-TRACC location was found to replicate the pure lateral response, it was found to be less than optimal to track oblique loading. Although a laterally positioned sensor provides lower peak deflections in oblique loading, the addition of an angle-measuring sensor should allow modulating the translational metric for this mode. From this perspective, it may be worthwhile to use a 2D IR-TRACC or an optical sensor to verify these findings without chestband measures. Such an analysis has the potential to modify thoracic and abdominal injury criteria to account for obliqueness.

AB - The objective of this study was to determine region-specific deflection responses of the WorldSID and ES2-re devices under pure lateral and oblique side impact loading. A modular, anthropometry-specific load wall was used. It consisted of the Shoulder, Thorax, Abdomen, superior Pelvis, and inferior Pelvis plates, termed the STAPP load wall design. The two devices were positioned upright on the platform of a bench seat, and sled tests were conducted at 3.4, 6.7, and 7.5 m/s. Two chestbands were used on each dummy at the thoracic and abdominal regions. Internal sensors were also used. Effective peak deflections were obtained from the chestband contours. Based on the preselected lateral-most point/location on the pretest contour, "internal sensor-type" peak deflections were also obtained using chestband contours. In addition, peak deflection data were obtained from internal sensor records. In oblique tests, the mean "IR-TRACC-type" peak deflections in the WorldSID device were 40 to 80% of effective peak deflections, whereas the mean "potentiometer-type" peak deflections in the ES2-device were 7 to 50%. The WorldSID device appears to better mimic region-specific responses to oblique loading than the ES2-re device, likely due to the differences in its design of the thoracic and abdominal regions. While the lateral-most point corresponding to the current 1D IR-TRACC location was found to replicate the pure lateral response, it was found to be less than optimal to track oblique loading. Although a laterally positioned sensor provides lower peak deflections in oblique loading, the addition of an angle-measuring sensor should allow modulating the translational metric for this mode. From this perspective, it may be worthwhile to use a 2D IR-TRACC or an optical sensor to verify these findings without chestband measures. Such an analysis has the potential to modify thoracic and abdominal injury criteria to account for obliqueness.

KW - Biomechanics

KW - Crash test dummy

KW - Deflection

KW - Injury metric

KW - Lateral impact

KW - Oblique loading

KW - Sled test

UR - http://www.scopus.com/inward/record.url?scp=85059429145&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85059429145&partnerID=8YFLogxK

U2 - 10.4271/2011-22-0013

DO - 10.4271/2011-22-0013

M3 - Conference article

VL - 2011-November

JO - SAE Technical Papers

JF - SAE Technical Papers

SN - 0148-7191

IS - November

ER -