Reduced field of view MRI with rapid, B 1-robust outer volume suppression

Travis Smith, Krishna S. Nayak

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

MRI scans are inefficient when the size of the anatomy under investigation is small relative to the subject's full extent. The field of view must be expanded, and acquisition times accordingly prolonged. Shorter scans are feasible with reduced field of view imaging (rFOV) using outer volume suppression (OVS), a magnetization preparation sequence that attenuates signal outside a region of interest (ROI). This work presents a new OVS sequence with a cylindrical ROI, short duration, and improved tolerance for B 1 + inhomogeneity. The sequence consists of a nonselective adiabatic tipdown pulse, which provides B 1 +-robust signal suppression, and a fast 2D spiral cylindrical tipback pulse. Analysis of the Bloch equations with transverse initial magnetization reveals a conjugate symmetric constraint for tipback pulses with small flip angles. This property is exploited to achieve two-shot performance from the single-shot tipback pulse. The OVS sequence is validated in phantoms and in vivo with multislice spiral imaging at 3 T. The relative signal-to-noise ratio efficiency of the proposed sequence was 98% in a phantom and 75-90% in vivo. The effectiveness is demonstrated with cardiovascular rFOV imaging, which exhibits improved resolution and reduced artifacts compared to conventional, full field of view imaging.

Original languageEnglish (US)
Pages (from-to)1316-1323
Number of pages8
JournalMagnetic Resonance in Medicine
Volume67
Issue number5
DOIs
StatePublished - May 2012
Externally publishedYes

Fingerprint

Signal-To-Noise Ratio
Protein Sorting Signals
Artifacts
Anatomy
Magnetic Resonance Imaging

Keywords

  • outer volume suppression
  • reduced field of view imaging
  • RF pulse design
  • spiral imaging

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Reduced field of view MRI with rapid, B 1-robust outer volume suppression. / Smith, Travis; Nayak, Krishna S.

In: Magnetic Resonance in Medicine, Vol. 67, No. 5, 05.2012, p. 1316-1323.

Research output: Contribution to journalArticle

Smith, Travis ; Nayak, Krishna S. / Reduced field of view MRI with rapid, B 1-robust outer volume suppression. In: Magnetic Resonance in Medicine. 2012 ; Vol. 67, No. 5. pp. 1316-1323.
@article{6f9db99795084c519c2e39fa3d8726f6,
title = "Reduced field of view MRI with rapid, B 1-robust outer volume suppression",
abstract = "MRI scans are inefficient when the size of the anatomy under investigation is small relative to the subject's full extent. The field of view must be expanded, and acquisition times accordingly prolonged. Shorter scans are feasible with reduced field of view imaging (rFOV) using outer volume suppression (OVS), a magnetization preparation sequence that attenuates signal outside a region of interest (ROI). This work presents a new OVS sequence with a cylindrical ROI, short duration, and improved tolerance for B 1 + inhomogeneity. The sequence consists of a nonselective adiabatic tipdown pulse, which provides B 1 +-robust signal suppression, and a fast 2D spiral cylindrical tipback pulse. Analysis of the Bloch equations with transverse initial magnetization reveals a conjugate symmetric constraint for tipback pulses with small flip angles. This property is exploited to achieve two-shot performance from the single-shot tipback pulse. The OVS sequence is validated in phantoms and in vivo with multislice spiral imaging at 3 T. The relative signal-to-noise ratio efficiency of the proposed sequence was 98{\%} in a phantom and 75-90{\%} in vivo. The effectiveness is demonstrated with cardiovascular rFOV imaging, which exhibits improved resolution and reduced artifacts compared to conventional, full field of view imaging.",
keywords = "outer volume suppression, reduced field of view imaging, RF pulse design, spiral imaging",
author = "Travis Smith and Nayak, {Krishna S.}",
year = "2012",
month = "5",
doi = "10.1002/mrm.23116",
language = "English (US)",
volume = "67",
pages = "1316--1323",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "5",

}

TY - JOUR

T1 - Reduced field of view MRI with rapid, B 1-robust outer volume suppression

AU - Smith, Travis

AU - Nayak, Krishna S.

PY - 2012/5

Y1 - 2012/5

N2 - MRI scans are inefficient when the size of the anatomy under investigation is small relative to the subject's full extent. The field of view must be expanded, and acquisition times accordingly prolonged. Shorter scans are feasible with reduced field of view imaging (rFOV) using outer volume suppression (OVS), a magnetization preparation sequence that attenuates signal outside a region of interest (ROI). This work presents a new OVS sequence with a cylindrical ROI, short duration, and improved tolerance for B 1 + inhomogeneity. The sequence consists of a nonselective adiabatic tipdown pulse, which provides B 1 +-robust signal suppression, and a fast 2D spiral cylindrical tipback pulse. Analysis of the Bloch equations with transverse initial magnetization reveals a conjugate symmetric constraint for tipback pulses with small flip angles. This property is exploited to achieve two-shot performance from the single-shot tipback pulse. The OVS sequence is validated in phantoms and in vivo with multislice spiral imaging at 3 T. The relative signal-to-noise ratio efficiency of the proposed sequence was 98% in a phantom and 75-90% in vivo. The effectiveness is demonstrated with cardiovascular rFOV imaging, which exhibits improved resolution and reduced artifacts compared to conventional, full field of view imaging.

AB - MRI scans are inefficient when the size of the anatomy under investigation is small relative to the subject's full extent. The field of view must be expanded, and acquisition times accordingly prolonged. Shorter scans are feasible with reduced field of view imaging (rFOV) using outer volume suppression (OVS), a magnetization preparation sequence that attenuates signal outside a region of interest (ROI). This work presents a new OVS sequence with a cylindrical ROI, short duration, and improved tolerance for B 1 + inhomogeneity. The sequence consists of a nonselective adiabatic tipdown pulse, which provides B 1 +-robust signal suppression, and a fast 2D spiral cylindrical tipback pulse. Analysis of the Bloch equations with transverse initial magnetization reveals a conjugate symmetric constraint for tipback pulses with small flip angles. This property is exploited to achieve two-shot performance from the single-shot tipback pulse. The OVS sequence is validated in phantoms and in vivo with multislice spiral imaging at 3 T. The relative signal-to-noise ratio efficiency of the proposed sequence was 98% in a phantom and 75-90% in vivo. The effectiveness is demonstrated with cardiovascular rFOV imaging, which exhibits improved resolution and reduced artifacts compared to conventional, full field of view imaging.

KW - outer volume suppression

KW - reduced field of view imaging

KW - RF pulse design

KW - spiral imaging

UR - http://www.scopus.com/inward/record.url?scp=84859717228&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84859717228&partnerID=8YFLogxK

U2 - 10.1002/mrm.23116

DO - 10.1002/mrm.23116

M3 - Article

VL - 67

SP - 1316

EP - 1323

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 5

ER -