Quantification of isotopically overlapping deamidated and 18O-labeled peptides using isotopic Envelope mixture modeling

Surendra Dasari, Phillip Wilmarth, Ashok P. Reddy, Lucinda J G Robertson, Srinivasa R. Nagalla, Larry David

Research output: Contribution to journalArticle

30 Citations (Scopus)

Abstract

A robust peptide quantification method was developed where overlapping peptide isotopic distributions were fit with predicted peptide isotopic envelope mixture models (IEMMs). Application to two difficult quantitative problems was demonstrated. The first was the quantification of deamidation, where masses of isotopic peaks differ by 1 Da, and the second was 18O labeling, where the isotopic peaks are shifted 2 and 4 Da. In both cases, peptide quantification cannot be performed by simple integration of extracted ion chromatograms, because the isotopic envelopes of mass-shifted peptides are normally not resolved. To test the methodology for quantification of deamidation, several synthetic peptides and their corresponding deamidated forms were mixed at various ratios (1:0, 1:2, 2:1, 4:1, 10:1, and 20:1) and analyzed using the IEMM method, resulting in a high correlation (R 2 = 0.96) between measured and known percentages of deamidation. The IEMM method was then incorporated into a workflow for deamidation quantification in a large-scale proteomics experiment. A series of normal (3 day, 2 year, 35 year, and 70 year) and cataractous (93 year) human lenses were analyzed using two-dimensional liquid chromatography tandem mass spectrometry, and deamidation quantities of several γS-crystallin peptides ([N14-Q16], N53, [Q63-Q70], and N143) were determined. Two peptides (N53 and [Q63-Q70]) had more extensive deamidation in the water-insoluble portions of normal lens samples, and deamidation at N143 was more extensive in the 93 year water-insoluble cataractous sample. The utility of the technique for analysis of 18O-labeled peptides was examined using mixtures of labeled BSA peptides in known 16 O/ 18O ratios (10:1, 4:1, 1:1, 1:4, and 1:10). The methodology allowed for accurate measurements of ratios of 16O/ 18O peptides over the wide range of relative abundances.

Original languageEnglish (US)
Pages (from-to)1263-1270
Number of pages8
JournalJournal of Proteome Research
Volume8
Issue number3
DOIs
StatePublished - Mar 6 2009

Fingerprint

Peptides
Lenses
Crystallins
Workflow
Water
Liquid chromatography
Tandem Mass Spectrometry
Liquid Chromatography
Proteomics
Labeling
Mass spectrometry
Ions
Experiments

Keywords

  • Bioinformatics
  • Cataracts, o labeling
  • Crystallin
  • Deamidation
  • Human lens
  • Insolubility
  • Isotopic envelope modeling
  • Mass spectrometry
  • Post-translational modification
  • Proteomics
  • Q-TOF
  • Quantification
  • Reverse-phase chromatography
  • Software

ASJC Scopus subject areas

  • Biochemistry
  • Chemistry(all)

Cite this

Quantification of isotopically overlapping deamidated and 18O-labeled peptides using isotopic Envelope mixture modeling. / Dasari, Surendra; Wilmarth, Phillip; Reddy, Ashok P.; Robertson, Lucinda J G; Nagalla, Srinivasa R.; David, Larry.

In: Journal of Proteome Research, Vol. 8, No. 3, 06.03.2009, p. 1263-1270.

Research output: Contribution to journalArticle

Dasari, Surendra ; Wilmarth, Phillip ; Reddy, Ashok P. ; Robertson, Lucinda J G ; Nagalla, Srinivasa R. ; David, Larry. / Quantification of isotopically overlapping deamidated and 18O-labeled peptides using isotopic Envelope mixture modeling. In: Journal of Proteome Research. 2009 ; Vol. 8, No. 3. pp. 1263-1270.
@article{8c3b41d04c43443d88829294b65a4fd4,
title = "Quantification of isotopically overlapping deamidated and 18O-labeled peptides using isotopic Envelope mixture modeling",
abstract = "A robust peptide quantification method was developed where overlapping peptide isotopic distributions were fit with predicted peptide isotopic envelope mixture models (IEMMs). Application to two difficult quantitative problems was demonstrated. The first was the quantification of deamidation, where masses of isotopic peaks differ by 1 Da, and the second was 18O labeling, where the isotopic peaks are shifted 2 and 4 Da. In both cases, peptide quantification cannot be performed by simple integration of extracted ion chromatograms, because the isotopic envelopes of mass-shifted peptides are normally not resolved. To test the methodology for quantification of deamidation, several synthetic peptides and their corresponding deamidated forms were mixed at various ratios (1:0, 1:2, 2:1, 4:1, 10:1, and 20:1) and analyzed using the IEMM method, resulting in a high correlation (R 2 = 0.96) between measured and known percentages of deamidation. The IEMM method was then incorporated into a workflow for deamidation quantification in a large-scale proteomics experiment. A series of normal (3 day, 2 year, 35 year, and 70 year) and cataractous (93 year) human lenses were analyzed using two-dimensional liquid chromatography tandem mass spectrometry, and deamidation quantities of several γS-crystallin peptides ([N14-Q16], N53, [Q63-Q70], and N143) were determined. Two peptides (N53 and [Q63-Q70]) had more extensive deamidation in the water-insoluble portions of normal lens samples, and deamidation at N143 was more extensive in the 93 year water-insoluble cataractous sample. The utility of the technique for analysis of 18O-labeled peptides was examined using mixtures of labeled BSA peptides in known 16 O/ 18O ratios (10:1, 4:1, 1:1, 1:4, and 1:10). The methodology allowed for accurate measurements of ratios of 16O/ 18O peptides over the wide range of relative abundances.",
keywords = "Bioinformatics, Cataracts, o labeling, Crystallin, Deamidation, Human lens, Insolubility, Isotopic envelope modeling, Mass spectrometry, Post-translational modification, Proteomics, Q-TOF, Quantification, Reverse-phase chromatography, Software",
author = "Surendra Dasari and Phillip Wilmarth and Reddy, {Ashok P.} and Robertson, {Lucinda J G} and Nagalla, {Srinivasa R.} and Larry David",
year = "2009",
month = "3",
day = "6",
doi = "10.1021/pr801054w",
language = "English (US)",
volume = "8",
pages = "1263--1270",
journal = "Journal of Proteome Research",
issn = "1535-3893",
publisher = "American Chemical Society",
number = "3",

}

TY - JOUR

T1 - Quantification of isotopically overlapping deamidated and 18O-labeled peptides using isotopic Envelope mixture modeling

AU - Dasari, Surendra

AU - Wilmarth, Phillip

AU - Reddy, Ashok P.

AU - Robertson, Lucinda J G

AU - Nagalla, Srinivasa R.

AU - David, Larry

PY - 2009/3/6

Y1 - 2009/3/6

N2 - A robust peptide quantification method was developed where overlapping peptide isotopic distributions were fit with predicted peptide isotopic envelope mixture models (IEMMs). Application to two difficult quantitative problems was demonstrated. The first was the quantification of deamidation, where masses of isotopic peaks differ by 1 Da, and the second was 18O labeling, where the isotopic peaks are shifted 2 and 4 Da. In both cases, peptide quantification cannot be performed by simple integration of extracted ion chromatograms, because the isotopic envelopes of mass-shifted peptides are normally not resolved. To test the methodology for quantification of deamidation, several synthetic peptides and their corresponding deamidated forms were mixed at various ratios (1:0, 1:2, 2:1, 4:1, 10:1, and 20:1) and analyzed using the IEMM method, resulting in a high correlation (R 2 = 0.96) between measured and known percentages of deamidation. The IEMM method was then incorporated into a workflow for deamidation quantification in a large-scale proteomics experiment. A series of normal (3 day, 2 year, 35 year, and 70 year) and cataractous (93 year) human lenses were analyzed using two-dimensional liquid chromatography tandem mass spectrometry, and deamidation quantities of several γS-crystallin peptides ([N14-Q16], N53, [Q63-Q70], and N143) were determined. Two peptides (N53 and [Q63-Q70]) had more extensive deamidation in the water-insoluble portions of normal lens samples, and deamidation at N143 was more extensive in the 93 year water-insoluble cataractous sample. The utility of the technique for analysis of 18O-labeled peptides was examined using mixtures of labeled BSA peptides in known 16 O/ 18O ratios (10:1, 4:1, 1:1, 1:4, and 1:10). The methodology allowed for accurate measurements of ratios of 16O/ 18O peptides over the wide range of relative abundances.

AB - A robust peptide quantification method was developed where overlapping peptide isotopic distributions were fit with predicted peptide isotopic envelope mixture models (IEMMs). Application to two difficult quantitative problems was demonstrated. The first was the quantification of deamidation, where masses of isotopic peaks differ by 1 Da, and the second was 18O labeling, where the isotopic peaks are shifted 2 and 4 Da. In both cases, peptide quantification cannot be performed by simple integration of extracted ion chromatograms, because the isotopic envelopes of mass-shifted peptides are normally not resolved. To test the methodology for quantification of deamidation, several synthetic peptides and their corresponding deamidated forms were mixed at various ratios (1:0, 1:2, 2:1, 4:1, 10:1, and 20:1) and analyzed using the IEMM method, resulting in a high correlation (R 2 = 0.96) between measured and known percentages of deamidation. The IEMM method was then incorporated into a workflow for deamidation quantification in a large-scale proteomics experiment. A series of normal (3 day, 2 year, 35 year, and 70 year) and cataractous (93 year) human lenses were analyzed using two-dimensional liquid chromatography tandem mass spectrometry, and deamidation quantities of several γS-crystallin peptides ([N14-Q16], N53, [Q63-Q70], and N143) were determined. Two peptides (N53 and [Q63-Q70]) had more extensive deamidation in the water-insoluble portions of normal lens samples, and deamidation at N143 was more extensive in the 93 year water-insoluble cataractous sample. The utility of the technique for analysis of 18O-labeled peptides was examined using mixtures of labeled BSA peptides in known 16 O/ 18O ratios (10:1, 4:1, 1:1, 1:4, and 1:10). The methodology allowed for accurate measurements of ratios of 16O/ 18O peptides over the wide range of relative abundances.

KW - Bioinformatics

KW - Cataracts, o labeling

KW - Crystallin

KW - Deamidation

KW - Human lens

KW - Insolubility

KW - Isotopic envelope modeling

KW - Mass spectrometry

KW - Post-translational modification

KW - Proteomics

KW - Q-TOF

KW - Quantification

KW - Reverse-phase chromatography

KW - Software

UR - http://www.scopus.com/inward/record.url?scp=65249098316&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=65249098316&partnerID=8YFLogxK

U2 - 10.1021/pr801054w

DO - 10.1021/pr801054w

M3 - Article

C2 - 19173613

AN - SCOPUS:65249098316

VL - 8

SP - 1263

EP - 1270

JO - Journal of Proteome Research

JF - Journal of Proteome Research

SN - 1535-3893

IS - 3

ER -