Prospective, multicenter study of P4HB (Phasix™) mesh for hernia repair in cohort at risk for complications: 3-Year follow-up

John Scott Roth, Gary J. Anthone, Don J. Selzer, Benjamin K. Poulose, Richard A. Pierce, James G. Bittner, William W. Hope, Raymond M. Dunn, Robert G. Martindale, Matthew I. Goldblatt, David B. Earle, John R. Romanelli, Gregory J. Mancini, Jacob A. Greenberg, John G. Linn, Eduardo Parra-Davila, Bryan J. Sandler, Corey R. Deeken, Jasenka Verbarg, Jennifer L. SalluzzoGuy R. Voeller

Research output: Contribution to journalArticlepeer-review

23 Scopus citations

Abstract

Background: This study represents a prospective, multicenter, open-label study to assess the safety, performance, and outcomes of poly-4-hydroxybutyrate (P4HB, Phasix™) mesh for primary ventral, primary incisional, or multiply-recurrent hernia in subjects at risk for complications. This study reports 3-year clinical outcomes. Materials and methods: P4HB mesh was implanted in 121 patients via retrorectus or onlay technique. Physical exam and/or quality of life surveys were completed at 1, 3, 6,12, 18, 24, and 36 months, with 5-year (60-month) follow-up ongoing. Results: A total of n = 121 patients were implanted with P4HB mesh (n = 75 (62%) female) with a mean age of 54.7 ± 12.0 years and mean BMI of 32.2 ± 4.5 kg/m2 (±standard deviation). Comorbidities included: obesity (78.5%), active smokers (23.1%), COPD (28.1%), diabetes mellitus (33.1%), immunosuppression (8.3%), coronary artery disease (21.5%), chronic corticosteroid use (5.0%), hypo-albuminemia (2.5%), advanced age (5.0%), and renal insufficiency (0.8%). Hernias were repaired via retrorectus (n = 45, 37.2% with myofascial release (MR) or n = 43, 35.5% without MR), onlay (n = 8, 6.6% with MR or n = 24, 19.8% without MR), or not reported (n = 1, 0.8%). 82 patients (67.8%) completed 36-month follow-up. 17 patients (17.9% ± 0.4%) experienced hernia recurrence at 3 years, with n = 9 in the retrorectus group and n = 8 in the onlay group. SSI (n = 11) occurred in 9.3% ± 0.03% of patients. Conclusions: Long-term outcomes following ventral hernia repair with P4HB mesh demonstrate low recurrence rates at 3-year (36-month) postoperative time frame with no patients developing late mesh complications or requiring mesh removal. 5-year (60-month) follow-up is ongoing.

Original languageEnglish (US)
Pages (from-to)1-7
Number of pages7
JournalAnnals of Medicine and Surgery
Volume61
DOIs
StatePublished - Jan 2021

Keywords

  • Hernia repair
  • Infection
  • Mesh
  • Poly-4-hydroxybutyrate
  • Recurrence
  • Seroma

ASJC Scopus subject areas

  • Surgery

Fingerprint

Dive into the research topics of 'Prospective, multicenter study of P4HB (Phasix™) mesh for hernia repair in cohort at risk for complications: 3-Year follow-up'. Together they form a unique fingerprint.

Cite this