Phasic changes in arterial blood volume is influenced by collateral blood flow: Implications for the quantification of coronary stenosis at rest

Marco Pascotto, Kevin Wei, Antonio Micari, Thanjavur Bragadeesh, Norman Craig Goodman, Sanjiv Kaul

    Research output: Contribution to journalArticle

    6 Citations (Scopus)

    Abstract

    Background: The systolic to diastolic arteriolar blood volume (aBV) ratio derived using myocardial contrast echocardiography (MCE) can identify the presence of coronary stenosis at rest. There are some patients with moderate to severe coronary stenosis who nonetheless exhibit a normal systolic to disatolic aBV ratio. Aim: To test the hypothesis that collateral blood flow influences the systolic to diastolic aBV ratio. MCE-defined phasic changes in aBV were recorded at baseline and up to 2 degrees of non-critical stenosis in 12 dogs. Measurements were made from MCE-defined collateralised and non-collateralised portions of the left anterior descending arterial bed. Results: Increases in both systolic and diastolic aBV were noted in the non-collateralised region with increasing degrees of stenosis. Although these increases in the absolute values did not reach statistical significance, the systolic to diastolic aBV signal ratio in the non-collateralised bed increased significantly between stages (analysis of variance, p = 0.003). In comparison, in the collateralised bed neither the absolute systolic nor diastolic aBV signals changed with increasing degrees of stenosis. Consequently, the aBV signal ratio between systole and diastole also did not change in this bed. Conclusion: Phasic changes in aBV are influenced by the degree of collateral blood flow. Thus, if the region of interest is not placed in the centre of the vascular bed, the degree of stenosis may be underestimated by the systolic to diastolic aBV ratio. On the other hand, as extensive collateralisation may indicate excellent prognosis, this ratio may provide prognostic information independent of the coronary anatomy.

    Original languageEnglish (US)
    Pages (from-to)438-443
    Number of pages6
    JournalHeart
    Volume93
    Issue number4
    DOIs
    StatePublished - Apr 2007

    Fingerprint

    Coronary Stenosis
    Blood Volume
    Pathologic Constriction
    Echocardiography
    Diastole
    Systole
    Blood Vessels
    Anatomy
    Analysis of Variance
    Dogs

    ASJC Scopus subject areas

    • Cardiology and Cardiovascular Medicine

    Cite this

    Phasic changes in arterial blood volume is influenced by collateral blood flow : Implications for the quantification of coronary stenosis at rest. / Pascotto, Marco; Wei, Kevin; Micari, Antonio; Bragadeesh, Thanjavur; Goodman, Norman Craig; Kaul, Sanjiv.

    In: Heart, Vol. 93, No. 4, 04.2007, p. 438-443.

    Research output: Contribution to journalArticle

    Pascotto, Marco ; Wei, Kevin ; Micari, Antonio ; Bragadeesh, Thanjavur ; Goodman, Norman Craig ; Kaul, Sanjiv. / Phasic changes in arterial blood volume is influenced by collateral blood flow : Implications for the quantification of coronary stenosis at rest. In: Heart. 2007 ; Vol. 93, No. 4. pp. 438-443.
    @article{f9c27d52f6834130a1d88997193ad67c,
    title = "Phasic changes in arterial blood volume is influenced by collateral blood flow: Implications for the quantification of coronary stenosis at rest",
    abstract = "Background: The systolic to diastolic arteriolar blood volume (aBV) ratio derived using myocardial contrast echocardiography (MCE) can identify the presence of coronary stenosis at rest. There are some patients with moderate to severe coronary stenosis who nonetheless exhibit a normal systolic to disatolic aBV ratio. Aim: To test the hypothesis that collateral blood flow influences the systolic to diastolic aBV ratio. MCE-defined phasic changes in aBV were recorded at baseline and up to 2 degrees of non-critical stenosis in 12 dogs. Measurements were made from MCE-defined collateralised and non-collateralised portions of the left anterior descending arterial bed. Results: Increases in both systolic and diastolic aBV were noted in the non-collateralised region with increasing degrees of stenosis. Although these increases in the absolute values did not reach statistical significance, the systolic to diastolic aBV signal ratio in the non-collateralised bed increased significantly between stages (analysis of variance, p = 0.003). In comparison, in the collateralised bed neither the absolute systolic nor diastolic aBV signals changed with increasing degrees of stenosis. Consequently, the aBV signal ratio between systole and diastole also did not change in this bed. Conclusion: Phasic changes in aBV are influenced by the degree of collateral blood flow. Thus, if the region of interest is not placed in the centre of the vascular bed, the degree of stenosis may be underestimated by the systolic to diastolic aBV ratio. On the other hand, as extensive collateralisation may indicate excellent prognosis, this ratio may provide prognostic information independent of the coronary anatomy.",
    author = "Marco Pascotto and Kevin Wei and Antonio Micari and Thanjavur Bragadeesh and Goodman, {Norman Craig} and Sanjiv Kaul",
    year = "2007",
    month = "4",
    doi = "10.1136/hrt.2006.089631",
    language = "English (US)",
    volume = "93",
    pages = "438--443",
    journal = "Heart",
    issn = "1355-6037",
    publisher = "BMJ Publishing Group",
    number = "4",

    }

    TY - JOUR

    T1 - Phasic changes in arterial blood volume is influenced by collateral blood flow

    T2 - Implications for the quantification of coronary stenosis at rest

    AU - Pascotto, Marco

    AU - Wei, Kevin

    AU - Micari, Antonio

    AU - Bragadeesh, Thanjavur

    AU - Goodman, Norman Craig

    AU - Kaul, Sanjiv

    PY - 2007/4

    Y1 - 2007/4

    N2 - Background: The systolic to diastolic arteriolar blood volume (aBV) ratio derived using myocardial contrast echocardiography (MCE) can identify the presence of coronary stenosis at rest. There are some patients with moderate to severe coronary stenosis who nonetheless exhibit a normal systolic to disatolic aBV ratio. Aim: To test the hypothesis that collateral blood flow influences the systolic to diastolic aBV ratio. MCE-defined phasic changes in aBV were recorded at baseline and up to 2 degrees of non-critical stenosis in 12 dogs. Measurements were made from MCE-defined collateralised and non-collateralised portions of the left anterior descending arterial bed. Results: Increases in both systolic and diastolic aBV were noted in the non-collateralised region with increasing degrees of stenosis. Although these increases in the absolute values did not reach statistical significance, the systolic to diastolic aBV signal ratio in the non-collateralised bed increased significantly between stages (analysis of variance, p = 0.003). In comparison, in the collateralised bed neither the absolute systolic nor diastolic aBV signals changed with increasing degrees of stenosis. Consequently, the aBV signal ratio between systole and diastole also did not change in this bed. Conclusion: Phasic changes in aBV are influenced by the degree of collateral blood flow. Thus, if the region of interest is not placed in the centre of the vascular bed, the degree of stenosis may be underestimated by the systolic to diastolic aBV ratio. On the other hand, as extensive collateralisation may indicate excellent prognosis, this ratio may provide prognostic information independent of the coronary anatomy.

    AB - Background: The systolic to diastolic arteriolar blood volume (aBV) ratio derived using myocardial contrast echocardiography (MCE) can identify the presence of coronary stenosis at rest. There are some patients with moderate to severe coronary stenosis who nonetheless exhibit a normal systolic to disatolic aBV ratio. Aim: To test the hypothesis that collateral blood flow influences the systolic to diastolic aBV ratio. MCE-defined phasic changes in aBV were recorded at baseline and up to 2 degrees of non-critical stenosis in 12 dogs. Measurements were made from MCE-defined collateralised and non-collateralised portions of the left anterior descending arterial bed. Results: Increases in both systolic and diastolic aBV were noted in the non-collateralised region with increasing degrees of stenosis. Although these increases in the absolute values did not reach statistical significance, the systolic to diastolic aBV signal ratio in the non-collateralised bed increased significantly between stages (analysis of variance, p = 0.003). In comparison, in the collateralised bed neither the absolute systolic nor diastolic aBV signals changed with increasing degrees of stenosis. Consequently, the aBV signal ratio between systole and diastole also did not change in this bed. Conclusion: Phasic changes in aBV are influenced by the degree of collateral blood flow. Thus, if the region of interest is not placed in the centre of the vascular bed, the degree of stenosis may be underestimated by the systolic to diastolic aBV ratio. On the other hand, as extensive collateralisation may indicate excellent prognosis, this ratio may provide prognostic information independent of the coronary anatomy.

    UR - http://www.scopus.com/inward/record.url?scp=34247364004&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=34247364004&partnerID=8YFLogxK

    U2 - 10.1136/hrt.2006.089631

    DO - 10.1136/hrt.2006.089631

    M3 - Article

    C2 - 17005716

    AN - SCOPUS:34247364004

    VL - 93

    SP - 438

    EP - 443

    JO - Heart

    JF - Heart

    SN - 1355-6037

    IS - 4

    ER -