Nonlinear finite element contact analysis of dental implant components

Ronald Sakaguchi, Svenn E. Borgersen

Research output: Contribution to journalArticle

Abstract

The treatment design of most dental restorations is largely empirical and based on the experience of the individual practitioner. Because the biomechanical aspects of implant-supported restorations are difficult to assess on an individual basis, there is a possibility for compromised biomechanical performance of the implant-retained restoration to achieve satisfactory esthetics and phonetics. Through repeated loading cycles, the restoration or its components may fatigue and fail. This study evaluated the biomechanical behavior of the crown component relative to the gold retaining screw and abutment under load to provide insight into the mechanism of loosening and fracture of the retaining screw. A two-dimensional finite element model of the dental implant components was developed for nonlinear contact analysis. A simulation of tightening of the retaining screw was followed by axial loading of a cusp tip on the implant-supported crown. Loading of the cusp tip resulted in separation of the contact between (1) the gold retaining screw and abutment, and (2) the crown and the abutment. Repeated loading and unloading cycles resulted in alternating contact and separation between the retaining screw head base and the crown. Clinical findings of screw loosening and failure probably result from these separation events and from elevated strains in the screw as demonstrated by the model.

Original languageEnglish (US)
Pages (from-to)1-16
Number of pages16
JournalInternational Journal of Oral and Maxillofacial Implants
Volume8
Issue number6
StatePublished - 1993
Externally publishedYes

Fingerprint

Tooth Components
Finite Element Analysis
Dental Implants
Crowns
Gold
Phonetics
Weight-Bearing
Esthetics
Fatigue
Tooth
Head

Keywords

  • Contact analysis
  • Dental implant
  • Finite element analysis
  • Nonlinear
  • Prosthodontics

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Nonlinear finite element contact analysis of dental implant components. / Sakaguchi, Ronald; Borgersen, Svenn E.

In: International Journal of Oral and Maxillofacial Implants, Vol. 8, No. 6, 1993, p. 1-16.

Research output: Contribution to journalArticle

@article{ca79be38c8204b788b776c5f3726c245,
title = "Nonlinear finite element contact analysis of dental implant components",
abstract = "The treatment design of most dental restorations is largely empirical and based on the experience of the individual practitioner. Because the biomechanical aspects of implant-supported restorations are difficult to assess on an individual basis, there is a possibility for compromised biomechanical performance of the implant-retained restoration to achieve satisfactory esthetics and phonetics. Through repeated loading cycles, the restoration or its components may fatigue and fail. This study evaluated the biomechanical behavior of the crown component relative to the gold retaining screw and abutment under load to provide insight into the mechanism of loosening and fracture of the retaining screw. A two-dimensional finite element model of the dental implant components was developed for nonlinear contact analysis. A simulation of tightening of the retaining screw was followed by axial loading of a cusp tip on the implant-supported crown. Loading of the cusp tip resulted in separation of the contact between (1) the gold retaining screw and abutment, and (2) the crown and the abutment. Repeated loading and unloading cycles resulted in alternating contact and separation between the retaining screw head base and the crown. Clinical findings of screw loosening and failure probably result from these separation events and from elevated strains in the screw as demonstrated by the model.",
keywords = "Contact analysis, Dental implant, Finite element analysis, Nonlinear, Prosthodontics",
author = "Ronald Sakaguchi and Borgersen, {Svenn E.}",
year = "1993",
language = "English (US)",
volume = "8",
pages = "1--16",
journal = "The International journal of oral & maxillofacial implants",
issn = "0882-2786",
publisher = "Quintessence Publishing Company",
number = "6",

}

TY - JOUR

T1 - Nonlinear finite element contact analysis of dental implant components

AU - Sakaguchi, Ronald

AU - Borgersen, Svenn E.

PY - 1993

Y1 - 1993

N2 - The treatment design of most dental restorations is largely empirical and based on the experience of the individual practitioner. Because the biomechanical aspects of implant-supported restorations are difficult to assess on an individual basis, there is a possibility for compromised biomechanical performance of the implant-retained restoration to achieve satisfactory esthetics and phonetics. Through repeated loading cycles, the restoration or its components may fatigue and fail. This study evaluated the biomechanical behavior of the crown component relative to the gold retaining screw and abutment under load to provide insight into the mechanism of loosening and fracture of the retaining screw. A two-dimensional finite element model of the dental implant components was developed for nonlinear contact analysis. A simulation of tightening of the retaining screw was followed by axial loading of a cusp tip on the implant-supported crown. Loading of the cusp tip resulted in separation of the contact between (1) the gold retaining screw and abutment, and (2) the crown and the abutment. Repeated loading and unloading cycles resulted in alternating contact and separation between the retaining screw head base and the crown. Clinical findings of screw loosening and failure probably result from these separation events and from elevated strains in the screw as demonstrated by the model.

AB - The treatment design of most dental restorations is largely empirical and based on the experience of the individual practitioner. Because the biomechanical aspects of implant-supported restorations are difficult to assess on an individual basis, there is a possibility for compromised biomechanical performance of the implant-retained restoration to achieve satisfactory esthetics and phonetics. Through repeated loading cycles, the restoration or its components may fatigue and fail. This study evaluated the biomechanical behavior of the crown component relative to the gold retaining screw and abutment under load to provide insight into the mechanism of loosening and fracture of the retaining screw. A two-dimensional finite element model of the dental implant components was developed for nonlinear contact analysis. A simulation of tightening of the retaining screw was followed by axial loading of a cusp tip on the implant-supported crown. Loading of the cusp tip resulted in separation of the contact between (1) the gold retaining screw and abutment, and (2) the crown and the abutment. Repeated loading and unloading cycles resulted in alternating contact and separation between the retaining screw head base and the crown. Clinical findings of screw loosening and failure probably result from these separation events and from elevated strains in the screw as demonstrated by the model.

KW - Contact analysis

KW - Dental implant

KW - Finite element analysis

KW - Nonlinear

KW - Prosthodontics

UR - http://www.scopus.com/inward/record.url?scp=84995794107&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84995794107&partnerID=8YFLogxK

M3 - Article

VL - 8

SP - 1

EP - 16

JO - The International journal of oral & maxillofacial implants

JF - The International journal of oral & maxillofacial implants

SN - 0882-2786

IS - 6

ER -