Nonlinear contact analysis of preload in dental implant screws.

Ronald Sakaguchi, S. E. Borgersen

Research output: Contribution to journalArticle

127 Citations (Scopus)

Abstract

Clinical studies indicate that loosening or fracture of dental implant prostheses occurs in 5% to 45% of cases during the first year. The nature of loosening or displacement of prosthetic components is complex, since it involves cycling fatigue, oral fluids, and varied chewing patterns and loads. A finite element contact analysis method was used to study the load-transfer mechanism between prosthetic components caused by torque application to the threaded fasteners used for assembly. Screw elongation is achieved while allowing for elastic recovery of the screw to produce a clamping force on the fastened elements. Clamping forces were additive along the axis of the prosthetic components. When the gold retaining screw is fastened into the abutment screw, clamping force on the implant is increased at the expense of decreasing the clamping force at the abutment screw-abutment interface by 50%. Maximum tensile stresses in the screws after preload were less than 55% of the yield stress.

Original languageEnglish (US)
Pages (from-to)295-302
Number of pages8
JournalThe International journal of oral & maxillofacial implants
Volume10
Issue number3
StatePublished - May 1995

Fingerprint

Dental Implants
Constriction
Dental Prosthesis
Finite Element Analysis
Mastication
Torque
Gold
Fatigue

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Nonlinear contact analysis of preload in dental implant screws. / Sakaguchi, Ronald; Borgersen, S. E.

In: The International journal of oral & maxillofacial implants, Vol. 10, No. 3, 05.1995, p. 295-302.

Research output: Contribution to journalArticle

@article{1b861aa25e3e4a6ea67ac01a3575d84a,
title = "Nonlinear contact analysis of preload in dental implant screws.",
abstract = "Clinical studies indicate that loosening or fracture of dental implant prostheses occurs in 5{\%} to 45{\%} of cases during the first year. The nature of loosening or displacement of prosthetic components is complex, since it involves cycling fatigue, oral fluids, and varied chewing patterns and loads. A finite element contact analysis method was used to study the load-transfer mechanism between prosthetic components caused by torque application to the threaded fasteners used for assembly. Screw elongation is achieved while allowing for elastic recovery of the screw to produce a clamping force on the fastened elements. Clamping forces were additive along the axis of the prosthetic components. When the gold retaining screw is fastened into the abutment screw, clamping force on the implant is increased at the expense of decreasing the clamping force at the abutment screw-abutment interface by 50{\%}. Maximum tensile stresses in the screws after preload were less than 55{\%} of the yield stress.",
author = "Ronald Sakaguchi and Borgersen, {S. E.}",
year = "1995",
month = "5",
language = "English (US)",
volume = "10",
pages = "295--302",
journal = "The International journal of oral & maxillofacial implants",
issn = "0882-2786",
publisher = "Quintessence Publishing Company",
number = "3",

}

TY - JOUR

T1 - Nonlinear contact analysis of preload in dental implant screws.

AU - Sakaguchi, Ronald

AU - Borgersen, S. E.

PY - 1995/5

Y1 - 1995/5

N2 - Clinical studies indicate that loosening or fracture of dental implant prostheses occurs in 5% to 45% of cases during the first year. The nature of loosening or displacement of prosthetic components is complex, since it involves cycling fatigue, oral fluids, and varied chewing patterns and loads. A finite element contact analysis method was used to study the load-transfer mechanism between prosthetic components caused by torque application to the threaded fasteners used for assembly. Screw elongation is achieved while allowing for elastic recovery of the screw to produce a clamping force on the fastened elements. Clamping forces were additive along the axis of the prosthetic components. When the gold retaining screw is fastened into the abutment screw, clamping force on the implant is increased at the expense of decreasing the clamping force at the abutment screw-abutment interface by 50%. Maximum tensile stresses in the screws after preload were less than 55% of the yield stress.

AB - Clinical studies indicate that loosening or fracture of dental implant prostheses occurs in 5% to 45% of cases during the first year. The nature of loosening or displacement of prosthetic components is complex, since it involves cycling fatigue, oral fluids, and varied chewing patterns and loads. A finite element contact analysis method was used to study the load-transfer mechanism between prosthetic components caused by torque application to the threaded fasteners used for assembly. Screw elongation is achieved while allowing for elastic recovery of the screw to produce a clamping force on the fastened elements. Clamping forces were additive along the axis of the prosthetic components. When the gold retaining screw is fastened into the abutment screw, clamping force on the implant is increased at the expense of decreasing the clamping force at the abutment screw-abutment interface by 50%. Maximum tensile stresses in the screws after preload were less than 55% of the yield stress.

UR - http://www.scopus.com/inward/record.url?scp=0029302999&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029302999&partnerID=8YFLogxK

M3 - Article

C2 - 7615325

AN - SCOPUS:0029302999

VL - 10

SP - 295

EP - 302

JO - The International journal of oral & maxillofacial implants

JF - The International journal of oral & maxillofacial implants

SN - 0882-2786

IS - 3

ER -