Myocardial perfusion acquisition without magnetization preparation or gating

Edward V R Dibella, Liyong Chen, Matthias Schabel, Ganesh Adluru, Chris J. McGann

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

Current myocardial perfusion MRI acquisitions are performed with a saturation recovery sequence, in large part to minimize sensitivity to arrhythmia. A new approach is proposed here where the images are acquired ungated at steady state without use of a saturation pulse. The data are acquired continuously and reach steady state after the first few images. A confluence of advances has made this new paradigm of an ungated steady-state acquisition possibleâvery rapid undersampled readouts with new reconstruction technologies permit enough measurements that continuous acquisition becomes a feasible approach. Gating can be applied retrospectively from a logged electrocardiogram (ECG) or with self-gating methods. In this work, simulations and measurements in a concentration phantom are used to demonstrate that similar contrast and signal can be obtained with the standard saturation recovery and the proposed spoiled gradient echo (SPGR) acquisition. Specifically, for a flip angle of 14°and a saturation recovery time of 80 ms, similar signals are acquired over a range of T 1s that reflect realistic myocardial tissue concentrations. Preliminary results in one subject are presented to show the potential of this new approach. The method may allow for cine cardiac perfusion and more signal-to-noise ratio-efficient acquisitions.

Original languageEnglish (US)
Pages (from-to)609-613
Number of pages5
JournalMagnetic Resonance in Medicine
Volume67
Issue number3
DOIs
StatePublished - Mar 2012

Fingerprint

Perfusion
Signal-To-Noise Ratio
Cardiac Arrhythmias
Electrocardiography
Technology

Keywords

  • cardiac perfusion
  • CNR
  • contrast-enhanced MRI
  • gating
  • myocardial perfusion imaging
  • saturation recovery
  • ungated

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Myocardial perfusion acquisition without magnetization preparation or gating. / Dibella, Edward V R; Chen, Liyong; Schabel, Matthias; Adluru, Ganesh; McGann, Chris J.

In: Magnetic Resonance in Medicine, Vol. 67, No. 3, 03.2012, p. 609-613.

Research output: Contribution to journalArticle

Dibella, Edward V R ; Chen, Liyong ; Schabel, Matthias ; Adluru, Ganesh ; McGann, Chris J. / Myocardial perfusion acquisition without magnetization preparation or gating. In: Magnetic Resonance in Medicine. 2012 ; Vol. 67, No. 3. pp. 609-613.
@article{0c764cf77f8d47eabbd967f830403207,
title = "Myocardial perfusion acquisition without magnetization preparation or gating",
abstract = "Current myocardial perfusion MRI acquisitions are performed with a saturation recovery sequence, in large part to minimize sensitivity to arrhythmia. A new approach is proposed here where the images are acquired ungated at steady state without use of a saturation pulse. The data are acquired continuously and reach steady state after the first few images. A confluence of advances has made this new paradigm of an ungated steady-state acquisition possible{\^a}very rapid undersampled readouts with new reconstruction technologies permit enough measurements that continuous acquisition becomes a feasible approach. Gating can be applied retrospectively from a logged electrocardiogram (ECG) or with self-gating methods. In this work, simulations and measurements in a concentration phantom are used to demonstrate that similar contrast and signal can be obtained with the standard saturation recovery and the proposed spoiled gradient echo (SPGR) acquisition. Specifically, for a flip angle of 14°and a saturation recovery time of 80 ms, similar signals are acquired over a range of T 1s that reflect realistic myocardial tissue concentrations. Preliminary results in one subject are presented to show the potential of this new approach. The method may allow for cine cardiac perfusion and more signal-to-noise ratio-efficient acquisitions.",
keywords = "cardiac perfusion, CNR, contrast-enhanced MRI, gating, myocardial perfusion imaging, saturation recovery, ungated",
author = "Dibella, {Edward V R} and Liyong Chen and Matthias Schabel and Ganesh Adluru and McGann, {Chris J.}",
year = "2012",
month = "3",
doi = "10.1002/mrm.23318",
language = "English (US)",
volume = "67",
pages = "609--613",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "3",

}

TY - JOUR

T1 - Myocardial perfusion acquisition without magnetization preparation or gating

AU - Dibella, Edward V R

AU - Chen, Liyong

AU - Schabel, Matthias

AU - Adluru, Ganesh

AU - McGann, Chris J.

PY - 2012/3

Y1 - 2012/3

N2 - Current myocardial perfusion MRI acquisitions are performed with a saturation recovery sequence, in large part to minimize sensitivity to arrhythmia. A new approach is proposed here where the images are acquired ungated at steady state without use of a saturation pulse. The data are acquired continuously and reach steady state after the first few images. A confluence of advances has made this new paradigm of an ungated steady-state acquisition possibleâvery rapid undersampled readouts with new reconstruction technologies permit enough measurements that continuous acquisition becomes a feasible approach. Gating can be applied retrospectively from a logged electrocardiogram (ECG) or with self-gating methods. In this work, simulations and measurements in a concentration phantom are used to demonstrate that similar contrast and signal can be obtained with the standard saturation recovery and the proposed spoiled gradient echo (SPGR) acquisition. Specifically, for a flip angle of 14°and a saturation recovery time of 80 ms, similar signals are acquired over a range of T 1s that reflect realistic myocardial tissue concentrations. Preliminary results in one subject are presented to show the potential of this new approach. The method may allow for cine cardiac perfusion and more signal-to-noise ratio-efficient acquisitions.

AB - Current myocardial perfusion MRI acquisitions are performed with a saturation recovery sequence, in large part to minimize sensitivity to arrhythmia. A new approach is proposed here where the images are acquired ungated at steady state without use of a saturation pulse. The data are acquired continuously and reach steady state after the first few images. A confluence of advances has made this new paradigm of an ungated steady-state acquisition possibleâvery rapid undersampled readouts with new reconstruction technologies permit enough measurements that continuous acquisition becomes a feasible approach. Gating can be applied retrospectively from a logged electrocardiogram (ECG) or with self-gating methods. In this work, simulations and measurements in a concentration phantom are used to demonstrate that similar contrast and signal can be obtained with the standard saturation recovery and the proposed spoiled gradient echo (SPGR) acquisition. Specifically, for a flip angle of 14°and a saturation recovery time of 80 ms, similar signals are acquired over a range of T 1s that reflect realistic myocardial tissue concentrations. Preliminary results in one subject are presented to show the potential of this new approach. The method may allow for cine cardiac perfusion and more signal-to-noise ratio-efficient acquisitions.

KW - cardiac perfusion

KW - CNR

KW - contrast-enhanced MRI

KW - gating

KW - myocardial perfusion imaging

KW - saturation recovery

KW - ungated

UR - http://www.scopus.com/inward/record.url?scp=84857365816&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84857365816&partnerID=8YFLogxK

U2 - 10.1002/mrm.23318

DO - 10.1002/mrm.23318

M3 - Article

VL - 67

SP - 609

EP - 613

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 3

ER -