TY - JOUR
T1 - Missing pieces of the Piezo1/Piezo2 baroreceptor hypothesis
T2 - An autonomic perspective
AU - Stocker, Sean D.
AU - Sved, Alan F.
AU - Andresen, Michael C.
N1 - Publisher Copyright:
© 2019 the American Physiological Society.
PY - 2019
Y1 - 2019
N2 - Baroreceptors play a pivotal role in the regulation of blood pressure through moment to moment sensing of arterial blood pressure and providing information to the central nervous system to make autonomic adjustments to maintain appropriate tissue perfusion. A recent publication by Zeng and colleagues (Zeng WZ, Marshall KL, Min S, Daou I, Chapleau MW, Abboud FM, Liberles SD, Science 362: 464-467, 2018) suggests the mechanosensitive ion channels Piezo1 and Piezo2 represent the cellular mechanism by which baroreceptor nerve endings sense changes in arterial blood pressure. However, before Piezo1 and Piezo2 are accepted as the sensor of baroreceptors, the question must be asked of what criteria are necessary to establish this and how well the report of Zeng and colleagues (Zeng WZ, Marshall KL, Min S, Daou I, Chapleau MW, Abboud FM, Liberles SD, Science 362: 464-467, 2018) satisfies these criteria. We briefly review baroreceptor function, outline criteria that a putative neuronal sensor of blood pressure must satisfy, and discuss whether the recent findings of Zeng and colleagues suitably meet these criteria. Despite the provocative hypothesis, there are significant concerns regarding the evidence supporting a role of Piezo1/Piezo2 in arterial baroreceptor function.
AB - Baroreceptors play a pivotal role in the regulation of blood pressure through moment to moment sensing of arterial blood pressure and providing information to the central nervous system to make autonomic adjustments to maintain appropriate tissue perfusion. A recent publication by Zeng and colleagues (Zeng WZ, Marshall KL, Min S, Daou I, Chapleau MW, Abboud FM, Liberles SD, Science 362: 464-467, 2018) suggests the mechanosensitive ion channels Piezo1 and Piezo2 represent the cellular mechanism by which baroreceptor nerve endings sense changes in arterial blood pressure. However, before Piezo1 and Piezo2 are accepted as the sensor of baroreceptors, the question must be asked of what criteria are necessary to establish this and how well the report of Zeng and colleagues (Zeng WZ, Marshall KL, Min S, Daou I, Chapleau MW, Abboud FM, Liberles SD, Science 362: 464-467, 2018) satisfies these criteria. We briefly review baroreceptor function, outline criteria that a putative neuronal sensor of blood pressure must satisfy, and discuss whether the recent findings of Zeng and colleagues suitably meet these criteria. Despite the provocative hypothesis, there are significant concerns regarding the evidence supporting a role of Piezo1/Piezo2 in arterial baroreceptor function.
KW - Autonomic
KW - Baroreceptor
KW - Baroreflex
KW - Blood pressure
KW - Piezo
UR - http://www.scopus.com/inward/record.url?scp=85072234630&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85072234630&partnerID=8YFLogxK
U2 - 10.1152/jn.00315.2019
DO - 10.1152/jn.00315.2019
M3 - Review article
C2 - 31314636
AN - SCOPUS:85072234630
SN - 0022-3077
VL - 122
SP - 1207
EP - 1212
JO - Journal of Neurophysiology
JF - Journal of Neurophysiology
IS - 3
ER -