Microvessel diameter estimation: Error bias correction of serial measurements

F. P. Miles, Alfred Nuttall

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

The assessment of vessel patency can be substantially improved by serial microvessel diameter measurements taken successively along an extensive length of the vessel. It is possible to avoid making the a priori assumptions about the existence or location of local constriction sites implicit in single diameter measurements. The problem then becomes one of making sense of tens or hundreds of measurements for each vessel. Equivalent diameter is defined here as the diameter of a uniform circular cylinder of the same length as the original vessel, and having the same total resistance. Direct computation of the equivalent diameter, without taking measurement errors into account, leads to an underestimation of the true equivalent diameter even if the individual diameter measurements were not biased. We have developed a method for effectively eliminating this bias. It has been applied to serial microvessel diameter measurements of the guinea pig cochlea, automatically measured using an image analysis system (1). In this report, the results were developed for diameter estimates with an approximate gaussian distribution; however, the method is readily extended to other error distributions. Convergence of the bias compensation was rapid. Use of the new method is advisable with as few as three diameter estimates per vessel.

Original languageEnglish (US)
Pages (from-to)315-332
Number of pages18
JournalBiorheology
Volume28
Issue number3-4
StatePublished - 1991
Externally publishedYes

Fingerprint

Microvessels
Normal Distribution
Cochlea
Constriction
Guinea Pigs

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Microvessel diameter estimation : Error bias correction of serial measurements. / Miles, F. P.; Nuttall, Alfred.

In: Biorheology, Vol. 28, No. 3-4, 1991, p. 315-332.

Research output: Contribution to journalArticle

@article{67021d3905b04cdd941ed45f04373d33,
title = "Microvessel diameter estimation: Error bias correction of serial measurements",
abstract = "The assessment of vessel patency can be substantially improved by serial microvessel diameter measurements taken successively along an extensive length of the vessel. It is possible to avoid making the a priori assumptions about the existence or location of local constriction sites implicit in single diameter measurements. The problem then becomes one of making sense of tens or hundreds of measurements for each vessel. Equivalent diameter is defined here as the diameter of a uniform circular cylinder of the same length as the original vessel, and having the same total resistance. Direct computation of the equivalent diameter, without taking measurement errors into account, leads to an underestimation of the true equivalent diameter even if the individual diameter measurements were not biased. We have developed a method for effectively eliminating this bias. It has been applied to serial microvessel diameter measurements of the guinea pig cochlea, automatically measured using an image analysis system (1). In this report, the results were developed for diameter estimates with an approximate gaussian distribution; however, the method is readily extended to other error distributions. Convergence of the bias compensation was rapid. Use of the new method is advisable with as few as three diameter estimates per vessel.",
author = "Miles, {F. P.} and Alfred Nuttall",
year = "1991",
language = "English (US)",
volume = "28",
pages = "315--332",
journal = "Biorheology",
issn = "0006-355X",
publisher = "IOS Press",
number = "3-4",

}

TY - JOUR

T1 - Microvessel diameter estimation

T2 - Error bias correction of serial measurements

AU - Miles, F. P.

AU - Nuttall, Alfred

PY - 1991

Y1 - 1991

N2 - The assessment of vessel patency can be substantially improved by serial microvessel diameter measurements taken successively along an extensive length of the vessel. It is possible to avoid making the a priori assumptions about the existence or location of local constriction sites implicit in single diameter measurements. The problem then becomes one of making sense of tens or hundreds of measurements for each vessel. Equivalent diameter is defined here as the diameter of a uniform circular cylinder of the same length as the original vessel, and having the same total resistance. Direct computation of the equivalent diameter, without taking measurement errors into account, leads to an underestimation of the true equivalent diameter even if the individual diameter measurements were not biased. We have developed a method for effectively eliminating this bias. It has been applied to serial microvessel diameter measurements of the guinea pig cochlea, automatically measured using an image analysis system (1). In this report, the results were developed for diameter estimates with an approximate gaussian distribution; however, the method is readily extended to other error distributions. Convergence of the bias compensation was rapid. Use of the new method is advisable with as few as three diameter estimates per vessel.

AB - The assessment of vessel patency can be substantially improved by serial microvessel diameter measurements taken successively along an extensive length of the vessel. It is possible to avoid making the a priori assumptions about the existence or location of local constriction sites implicit in single diameter measurements. The problem then becomes one of making sense of tens or hundreds of measurements for each vessel. Equivalent diameter is defined here as the diameter of a uniform circular cylinder of the same length as the original vessel, and having the same total resistance. Direct computation of the equivalent diameter, without taking measurement errors into account, leads to an underestimation of the true equivalent diameter even if the individual diameter measurements were not biased. We have developed a method for effectively eliminating this bias. It has been applied to serial microvessel diameter measurements of the guinea pig cochlea, automatically measured using an image analysis system (1). In this report, the results were developed for diameter estimates with an approximate gaussian distribution; however, the method is readily extended to other error distributions. Convergence of the bias compensation was rapid. Use of the new method is advisable with as few as three diameter estimates per vessel.

UR - http://www.scopus.com/inward/record.url?scp=0025834499&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025834499&partnerID=8YFLogxK

M3 - Article

C2 - 1932720

AN - SCOPUS:0025834499

VL - 28

SP - 315

EP - 332

JO - Biorheology

JF - Biorheology

SN - 0006-355X

IS - 3-4

ER -