TY - JOUR
T1 - Measurement of Myocardial Blood Flow Velocity Reserve with Myocardial Contrast Echocardiography in Patients with Suspected Coronary Artery Disease
T2 - Comparison with Quantitative Gated Technetium 99m Sestamibi Single Photon Emission Computed Tomography
AU - Dawson, Dana
AU - Rinkevich, Diana
AU - Belcik, Todd
AU - Jayaweera, Ananda R.
AU - Rafter, Patrick
AU - Kaul, Sanjiv
AU - Wei, Kevin
PY - 2003/11
Y1 - 2003/11
N2 - Background: The ability of high and low mechanical index (MI) imaging methods during myocardial contrast echocardiography (MCE) to assess the physiologic significance of coronary stenoses were compared with technetium 99m sestamibi single photon emission computed tomography (SPECT) in patients. Methods: Intermittent ultraharmonic imaging (high MI) and power modulation angio (low MI) were performed during continuous infusions of the echoenhancing contrast agent, Optison, at rest and after dipyridamole stress in 39 patients. Technetium 99m sestamibi SPECT was performed simultaneously. Images from the 3 apical windows were divided into 6 walls. Myocardial blood flow (MBF) velocity and MBF velocity reserve were quantified from pulsing interval versus acoustic intensity MCE curves in each wall using postprocessed images. Results: Approximately 25% of the myocardial walls could not be analyzed from MCE because of artifacts. MBF velocity and MBF derived from both MCE methods increased significantly after dipyridamole in healthy patients (n = 143 and 129 walls for high and low MI, respectively), compared with those with either reversible (n = 11 and 10 walls for high and low MI, respectively) or fixed defects (n = 18 and 14 walls for high and low MI, respectively) on SPECT. Consequently, MBF velocity and MBF reserve were significantly greater for patients with normal perfusion. Receiver operator characteristic curves obtained for MBF velocity reserve provided a sensitivity and specificity of 82% and 87%, respectively, for high MI; versus 64% and 96%, respectively, for low MI imaging after uninterpretable images were excluded from analysis. Conclusions: Both high and low MI MCE imaging techniques can be used to determine the presence of perfusion defects as identified by technetium 99m sestamibi SPECT. Low MI imaging methods have a number of drawbacks that limit its sensitivity compared with high MI techniques.
AB - Background: The ability of high and low mechanical index (MI) imaging methods during myocardial contrast echocardiography (MCE) to assess the physiologic significance of coronary stenoses were compared with technetium 99m sestamibi single photon emission computed tomography (SPECT) in patients. Methods: Intermittent ultraharmonic imaging (high MI) and power modulation angio (low MI) were performed during continuous infusions of the echoenhancing contrast agent, Optison, at rest and after dipyridamole stress in 39 patients. Technetium 99m sestamibi SPECT was performed simultaneously. Images from the 3 apical windows were divided into 6 walls. Myocardial blood flow (MBF) velocity and MBF velocity reserve were quantified from pulsing interval versus acoustic intensity MCE curves in each wall using postprocessed images. Results: Approximately 25% of the myocardial walls could not be analyzed from MCE because of artifacts. MBF velocity and MBF derived from both MCE methods increased significantly after dipyridamole in healthy patients (n = 143 and 129 walls for high and low MI, respectively), compared with those with either reversible (n = 11 and 10 walls for high and low MI, respectively) or fixed defects (n = 18 and 14 walls for high and low MI, respectively) on SPECT. Consequently, MBF velocity and MBF reserve were significantly greater for patients with normal perfusion. Receiver operator characteristic curves obtained for MBF velocity reserve provided a sensitivity and specificity of 82% and 87%, respectively, for high MI; versus 64% and 96%, respectively, for low MI imaging after uninterpretable images were excluded from analysis. Conclusions: Both high and low MI MCE imaging techniques can be used to determine the presence of perfusion defects as identified by technetium 99m sestamibi SPECT. Low MI imaging methods have a number of drawbacks that limit its sensitivity compared with high MI techniques.
UR - http://www.scopus.com/inward/record.url?scp=0242609059&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0242609059&partnerID=8YFLogxK
U2 - 10.1067/S0894-7317(03)00646-1
DO - 10.1067/S0894-7317(03)00646-1
M3 - Article
C2 - 14608289
AN - SCOPUS:0242609059
SN - 0894-7317
VL - 16
SP - 1171
EP - 1177
JO - Journal of the American Society of Echocardiography
JF - Journal of the American Society of Echocardiography
IS - 11
ER -