Intensity modulated radiation therapy (IMRT) in the radiotherapy treatment of colo-rectal cancer: The influence of profile smoothing on the efficiency of delivery

Wolfram Laub, D. Yan, J. Robertson, A. Martinez

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Small bowel toxicity due to radiotherapy treatment of rectal cancer is common. The potential use of intensity modulated radiation therapy (IMRT) to reduce the volume of small bowel irradiated during radiation therapy (RT) for cancer has previously been reported. However, IMRT treatment implementation is relatively difficult for these patients. The PTV is large and has a concave shape, with the small bowel in very close proximity. Therefore, the intensity profile calculated by an inverse planning engine could be highly modulated and complicated to deliver. In this study, two methods were used to optimise IMRT plans for rectal cancer patients. Scatter contribution when backprojecting dose values to fluence values and a smoothing function were only implemented in the optimisation searching of one method. A common arrangement of five beams, each separated by equal gantry angle, was adopted. With both methods used, the dose coverage of the PTV was satisfactory. Small bowel irradiated to a dose of 95 % was reduced by about 70% as compared to a 3D conformal 3-field treatment technique. However, incorporation of scatter contribution and a smoothing function in the iteration of optimisation searching greatly reduced the degree of modulation in the two-dimensional intensity profiles. Instead of 120–160 step-and-shoot MLC segments only 30–60 segments were necessary to deliver the five intensity profiles. The number of monitor units per fraction was reduced accordingly to about one half. Therefore, by controlling the smoothness of the intensity profiles during optimisation, the produced IMRT plans could be delivered more efficiently. Moreover, the possibility to account for overlap of organs was found to be very valuable to avoid hot spots in these regions and to get the full DVHs of all organs at the same time.

Original languageEnglish (US)
Pages (from-to)189-198
Number of pages10
JournalJournal of Radiotherapy in Practice
Volume2
Issue number4
DOIs
StatePublished - 2002
Externally publishedYes

Fingerprint

Rectal Neoplasms
Radiotherapy
Therapeutics
Neoplasms

Keywords

  • colo-rectal cancer
  • Intensity modulated radiation therapy
  • small bowel toxicity

ASJC Scopus subject areas

  • Oncology
  • Radiology Nuclear Medicine and imaging

Cite this

Intensity modulated radiation therapy (IMRT) in the radiotherapy treatment of colo-rectal cancer : The influence of profile smoothing on the efficiency of delivery. / Laub, Wolfram; Yan, D.; Robertson, J.; Martinez, A.

In: Journal of Radiotherapy in Practice, Vol. 2, No. 4, 2002, p. 189-198.

Research output: Contribution to journalArticle

@article{2872ff441e0c4640a923dcbd7c05352a,
title = "Intensity modulated radiation therapy (IMRT) in the radiotherapy treatment of colo-rectal cancer: The influence of profile smoothing on the efficiency of delivery",
abstract = "Small bowel toxicity due to radiotherapy treatment of rectal cancer is common. The potential use of intensity modulated radiation therapy (IMRT) to reduce the volume of small bowel irradiated during radiation therapy (RT) for cancer has previously been reported. However, IMRT treatment implementation is relatively difficult for these patients. The PTV is large and has a concave shape, with the small bowel in very close proximity. Therefore, the intensity profile calculated by an inverse planning engine could be highly modulated and complicated to deliver. In this study, two methods were used to optimise IMRT plans for rectal cancer patients. Scatter contribution when backprojecting dose values to fluence values and a smoothing function were only implemented in the optimisation searching of one method. A common arrangement of five beams, each separated by equal gantry angle, was adopted. With both methods used, the dose coverage of the PTV was satisfactory. Small bowel irradiated to a dose of 95 {\%} was reduced by about 70{\%} as compared to a 3D conformal 3-field treatment technique. However, incorporation of scatter contribution and a smoothing function in the iteration of optimisation searching greatly reduced the degree of modulation in the two-dimensional intensity profiles. Instead of 120–160 step-and-shoot MLC segments only 30–60 segments were necessary to deliver the five intensity profiles. The number of monitor units per fraction was reduced accordingly to about one half. Therefore, by controlling the smoothness of the intensity profiles during optimisation, the produced IMRT plans could be delivered more efficiently. Moreover, the possibility to account for overlap of organs was found to be very valuable to avoid hot spots in these regions and to get the full DVHs of all organs at the same time.",
keywords = "colo-rectal cancer, Intensity modulated radiation therapy, small bowel toxicity",
author = "Wolfram Laub and D. Yan and J. Robertson and A. Martinez",
year = "2002",
doi = "10.1017/S1460396902000031",
language = "English (US)",
volume = "2",
pages = "189--198",
journal = "Journal of Radiotherapy in Practice",
issn = "1460-3969",
publisher = "Cambridge University Press",
number = "4",

}

TY - JOUR

T1 - Intensity modulated radiation therapy (IMRT) in the radiotherapy treatment of colo-rectal cancer

T2 - The influence of profile smoothing on the efficiency of delivery

AU - Laub, Wolfram

AU - Yan, D.

AU - Robertson, J.

AU - Martinez, A.

PY - 2002

Y1 - 2002

N2 - Small bowel toxicity due to radiotherapy treatment of rectal cancer is common. The potential use of intensity modulated radiation therapy (IMRT) to reduce the volume of small bowel irradiated during radiation therapy (RT) for cancer has previously been reported. However, IMRT treatment implementation is relatively difficult for these patients. The PTV is large and has a concave shape, with the small bowel in very close proximity. Therefore, the intensity profile calculated by an inverse planning engine could be highly modulated and complicated to deliver. In this study, two methods were used to optimise IMRT plans for rectal cancer patients. Scatter contribution when backprojecting dose values to fluence values and a smoothing function were only implemented in the optimisation searching of one method. A common arrangement of five beams, each separated by equal gantry angle, was adopted. With both methods used, the dose coverage of the PTV was satisfactory. Small bowel irradiated to a dose of 95 % was reduced by about 70% as compared to a 3D conformal 3-field treatment technique. However, incorporation of scatter contribution and a smoothing function in the iteration of optimisation searching greatly reduced the degree of modulation in the two-dimensional intensity profiles. Instead of 120–160 step-and-shoot MLC segments only 30–60 segments were necessary to deliver the five intensity profiles. The number of monitor units per fraction was reduced accordingly to about one half. Therefore, by controlling the smoothness of the intensity profiles during optimisation, the produced IMRT plans could be delivered more efficiently. Moreover, the possibility to account for overlap of organs was found to be very valuable to avoid hot spots in these regions and to get the full DVHs of all organs at the same time.

AB - Small bowel toxicity due to radiotherapy treatment of rectal cancer is common. The potential use of intensity modulated radiation therapy (IMRT) to reduce the volume of small bowel irradiated during radiation therapy (RT) for cancer has previously been reported. However, IMRT treatment implementation is relatively difficult for these patients. The PTV is large and has a concave shape, with the small bowel in very close proximity. Therefore, the intensity profile calculated by an inverse planning engine could be highly modulated and complicated to deliver. In this study, two methods were used to optimise IMRT plans for rectal cancer patients. Scatter contribution when backprojecting dose values to fluence values and a smoothing function were only implemented in the optimisation searching of one method. A common arrangement of five beams, each separated by equal gantry angle, was adopted. With both methods used, the dose coverage of the PTV was satisfactory. Small bowel irradiated to a dose of 95 % was reduced by about 70% as compared to a 3D conformal 3-field treatment technique. However, incorporation of scatter contribution and a smoothing function in the iteration of optimisation searching greatly reduced the degree of modulation in the two-dimensional intensity profiles. Instead of 120–160 step-and-shoot MLC segments only 30–60 segments were necessary to deliver the five intensity profiles. The number of monitor units per fraction was reduced accordingly to about one half. Therefore, by controlling the smoothness of the intensity profiles during optimisation, the produced IMRT plans could be delivered more efficiently. Moreover, the possibility to account for overlap of organs was found to be very valuable to avoid hot spots in these regions and to get the full DVHs of all organs at the same time.

KW - colo-rectal cancer

KW - Intensity modulated radiation therapy

KW - small bowel toxicity

UR - http://www.scopus.com/inward/record.url?scp=85007983828&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85007983828&partnerID=8YFLogxK

U2 - 10.1017/S1460396902000031

DO - 10.1017/S1460396902000031

M3 - Article

AN - SCOPUS:85007983828

VL - 2

SP - 189

EP - 198

JO - Journal of Radiotherapy in Practice

JF - Journal of Radiotherapy in Practice

SN - 1460-3969

IS - 4

ER -