Heart rate response to shock delivered via different implanted electrodes

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

The heart rate reaction elicited by electric shock was studied in rats stimulated via implanted electrodes that were placed entirely beneath the skin (subcutaneous electrodes) or were passed under and through the skin (cutaneous electrodes). Cutaneous shock elicited greater cardioaccelerations than subcutaneous shock except at very low intensities. This finding may help to explain differences in conditioned heart rate responses when these two types of electrodes are used to deliver shock stimuli.

Original languageEnglish (US)
Pages (from-to)975-977
Number of pages3
JournalPhysiology and Behavior
Volume36
Issue number5
DOIs
StatePublished - 1986

Fingerprint

Implanted Electrodes
Shock
Heart Rate
Skin
Electrodes

Keywords

  • Heart rate
  • Implanted electrodes
  • Shock
  • Subcutaneous stimulation

ASJC Scopus subject areas

  • Physiology (medical)
  • Behavioral Neuroscience

Cite this

Heart rate response to shock delivered via different implanted electrodes. / Peris, Joanna; Cunningham, Christopher.

In: Physiology and Behavior, Vol. 36, No. 5, 1986, p. 975-977.

Research output: Contribution to journalArticle

@article{3802bec5e955498d95a56b0227349ffe,
title = "Heart rate response to shock delivered via different implanted electrodes",
abstract = "The heart rate reaction elicited by electric shock was studied in rats stimulated via implanted electrodes that were placed entirely beneath the skin (subcutaneous electrodes) or were passed under and through the skin (cutaneous electrodes). Cutaneous shock elicited greater cardioaccelerations than subcutaneous shock except at very low intensities. This finding may help to explain differences in conditioned heart rate responses when these two types of electrodes are used to deliver shock stimuli.",
keywords = "Heart rate, Implanted electrodes, Shock, Subcutaneous stimulation",
author = "Joanna Peris and Christopher Cunningham",
year = "1986",
doi = "10.1016/0031-9384(86)90463-4",
language = "English (US)",
volume = "36",
pages = "975--977",
journal = "Physiology and Behavior",
issn = "0031-9384",
publisher = "Elsevier Inc.",
number = "5",

}

TY - JOUR

T1 - Heart rate response to shock delivered via different implanted electrodes

AU - Peris, Joanna

AU - Cunningham, Christopher

PY - 1986

Y1 - 1986

N2 - The heart rate reaction elicited by electric shock was studied in rats stimulated via implanted electrodes that were placed entirely beneath the skin (subcutaneous electrodes) or were passed under and through the skin (cutaneous electrodes). Cutaneous shock elicited greater cardioaccelerations than subcutaneous shock except at very low intensities. This finding may help to explain differences in conditioned heart rate responses when these two types of electrodes are used to deliver shock stimuli.

AB - The heart rate reaction elicited by electric shock was studied in rats stimulated via implanted electrodes that were placed entirely beneath the skin (subcutaneous electrodes) or were passed under and through the skin (cutaneous electrodes). Cutaneous shock elicited greater cardioaccelerations than subcutaneous shock except at very low intensities. This finding may help to explain differences in conditioned heart rate responses when these two types of electrodes are used to deliver shock stimuli.

KW - Heart rate

KW - Implanted electrodes

KW - Shock

KW - Subcutaneous stimulation

UR - http://www.scopus.com/inward/record.url?scp=0022624411&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0022624411&partnerID=8YFLogxK

U2 - 10.1016/0031-9384(86)90463-4

DO - 10.1016/0031-9384(86)90463-4

M3 - Article

VL - 36

SP - 975

EP - 977

JO - Physiology and Behavior

JF - Physiology and Behavior

SN - 0031-9384

IS - 5

ER -