Aims: This study aimed to assess the feasibility and accuracy of nongated four-dimensional echocardiography (4DE) for determining left ventricular (LV) stroke volume (SV) and mass in a fetal heart-sized LV model. Methods: A balloon was inserted into the LV of 20 fresh rabbit hearts and attached to a calibrated pulsatile pump. Ten hearts retaining the right ventricle were imaged in Group A. Ten hearts without the right ventricles (RVs) attached were imaged in Group B. Nongated 4D volumes were obtained using a Philips iU-22 system with an X6-1 matrix probe at SVs ranging from 1 to 5 mL at increments of 1 mL. At each SV, the volume displacement of the heart was measured at end-systole and end-diastole. Mass was determined by displacement at the conclusion of the experiment. Results: The images were analyzed offline by manually tracing endocardial and epicardial boundaries of stacked contours. An excellent correlation in SV and mass between echo-derived values and displacement values was demonstrated and accompanied by high coefficients of determination (R2) in both groups (SV: Group A: R2 = 0.9461, Group B: R2 = 0.9811; Mass: Group A: R2 = 0.9223, Group B: R2 = 0.9602; all P <0.001). Bland-Altman analyses showed a slight overestimation in both groups for both SV and LV mass. Conclusions: Nongated 4DE was demonstrated to be feasible and that it could accurately define SV and ventricular mass for a fetal heart-sized LV model. (Echocardiography 2014;31:1138-1145).

Original languageEnglish (US)
Pages (from-to)1138-1145
Number of pages8
JournalEchocardiography
Volume31
Issue number9
DOIs
StatePublished - 2014

Fingerprint

Fetal Heart
Stroke Volume
Four-Dimensional Echocardiography
Heart Ventricles
Cardiac Volume
Diastole
Systole
Echocardiography
Rabbits

Keywords

  • Fetal echocardiography
  • Four-dimensional echocardiography
  • Left ventricular mass

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Radiology Nuclear Medicine and imaging
  • Medicine(all)

Cite this

Zhu, M., Streiff, C., Panosian, J., Roundhill, D., Lapin, M., Tutschek, B., ... Sahn, D. (2014). Evaluation of stroke volume and ventricular mass in a fetal heart model: A novel four-dimensional echocardiographic analysis. Echocardiography, 31(9), 1138-1145. https://doi.org/10.1111/echo.12520

Evaluation of stroke volume and ventricular mass in a fetal heart model : A novel four-dimensional echocardiographic analysis. / Zhu, Meihua; Streiff, Cole; Panosian, Jill; Roundhill, David; Lapin, Michael; Tutschek, Boris; Ashraf, Muhammad; Sahn, David.

In: Echocardiography, Vol. 31, No. 9, 2014, p. 1138-1145.

Research output: Contribution to journalArticle

Zhu, M, Streiff, C, Panosian, J, Roundhill, D, Lapin, M, Tutschek, B, Ashraf, M & Sahn, D 2014, 'Evaluation of stroke volume and ventricular mass in a fetal heart model: A novel four-dimensional echocardiographic analysis', Echocardiography, vol. 31, no. 9, pp. 1138-1145. https://doi.org/10.1111/echo.12520
Zhu, Meihua ; Streiff, Cole ; Panosian, Jill ; Roundhill, David ; Lapin, Michael ; Tutschek, Boris ; Ashraf, Muhammad ; Sahn, David. / Evaluation of stroke volume and ventricular mass in a fetal heart model : A novel four-dimensional echocardiographic analysis. In: Echocardiography. 2014 ; Vol. 31, No. 9. pp. 1138-1145.
@article{ebf54fea2a0e4d8b9885ac3be0486880,
title = "Evaluation of stroke volume and ventricular mass in a fetal heart model: A novel four-dimensional echocardiographic analysis",
abstract = "Aims: This study aimed to assess the feasibility and accuracy of nongated four-dimensional echocardiography (4DE) for determining left ventricular (LV) stroke volume (SV) and mass in a fetal heart-sized LV model. Methods: A balloon was inserted into the LV of 20 fresh rabbit hearts and attached to a calibrated pulsatile pump. Ten hearts retaining the right ventricle were imaged in Group A. Ten hearts without the right ventricles (RVs) attached were imaged in Group B. Nongated 4D volumes were obtained using a Philips iU-22 system with an X6-1 matrix probe at SVs ranging from 1 to 5 mL at increments of 1 mL. At each SV, the volume displacement of the heart was measured at end-systole and end-diastole. Mass was determined by displacement at the conclusion of the experiment. Results: The images were analyzed offline by manually tracing endocardial and epicardial boundaries of stacked contours. An excellent correlation in SV and mass between echo-derived values and displacement values was demonstrated and accompanied by high coefficients of determination (R2) in both groups (SV: Group A: R2 = 0.9461, Group B: R2 = 0.9811; Mass: Group A: R2 = 0.9223, Group B: R2 = 0.9602; all P <0.001). Bland-Altman analyses showed a slight overestimation in both groups for both SV and LV mass. Conclusions: Nongated 4DE was demonstrated to be feasible and that it could accurately define SV and ventricular mass for a fetal heart-sized LV model. (Echocardiography 2014;31:1138-1145).",
keywords = "Fetal echocardiography, Four-dimensional echocardiography, Left ventricular mass",
author = "Meihua Zhu and Cole Streiff and Jill Panosian and David Roundhill and Michael Lapin and Boris Tutschek and Muhammad Ashraf and David Sahn",
year = "2014",
doi = "10.1111/echo.12520",
language = "English (US)",
volume = "31",
pages = "1138--1145",
journal = "Echocardiography",
issn = "0742-2822",
publisher = "Wiley-Blackwell",
number = "9",

}

TY - JOUR

T1 - Evaluation of stroke volume and ventricular mass in a fetal heart model

T2 - A novel four-dimensional echocardiographic analysis

AU - Zhu, Meihua

AU - Streiff, Cole

AU - Panosian, Jill

AU - Roundhill, David

AU - Lapin, Michael

AU - Tutschek, Boris

AU - Ashraf, Muhammad

AU - Sahn, David

PY - 2014

Y1 - 2014

N2 - Aims: This study aimed to assess the feasibility and accuracy of nongated four-dimensional echocardiography (4DE) for determining left ventricular (LV) stroke volume (SV) and mass in a fetal heart-sized LV model. Methods: A balloon was inserted into the LV of 20 fresh rabbit hearts and attached to a calibrated pulsatile pump. Ten hearts retaining the right ventricle were imaged in Group A. Ten hearts without the right ventricles (RVs) attached were imaged in Group B. Nongated 4D volumes were obtained using a Philips iU-22 system with an X6-1 matrix probe at SVs ranging from 1 to 5 mL at increments of 1 mL. At each SV, the volume displacement of the heart was measured at end-systole and end-diastole. Mass was determined by displacement at the conclusion of the experiment. Results: The images were analyzed offline by manually tracing endocardial and epicardial boundaries of stacked contours. An excellent correlation in SV and mass between echo-derived values and displacement values was demonstrated and accompanied by high coefficients of determination (R2) in both groups (SV: Group A: R2 = 0.9461, Group B: R2 = 0.9811; Mass: Group A: R2 = 0.9223, Group B: R2 = 0.9602; all P <0.001). Bland-Altman analyses showed a slight overestimation in both groups for both SV and LV mass. Conclusions: Nongated 4DE was demonstrated to be feasible and that it could accurately define SV and ventricular mass for a fetal heart-sized LV model. (Echocardiography 2014;31:1138-1145).

AB - Aims: This study aimed to assess the feasibility and accuracy of nongated four-dimensional echocardiography (4DE) for determining left ventricular (LV) stroke volume (SV) and mass in a fetal heart-sized LV model. Methods: A balloon was inserted into the LV of 20 fresh rabbit hearts and attached to a calibrated pulsatile pump. Ten hearts retaining the right ventricle were imaged in Group A. Ten hearts without the right ventricles (RVs) attached were imaged in Group B. Nongated 4D volumes were obtained using a Philips iU-22 system with an X6-1 matrix probe at SVs ranging from 1 to 5 mL at increments of 1 mL. At each SV, the volume displacement of the heart was measured at end-systole and end-diastole. Mass was determined by displacement at the conclusion of the experiment. Results: The images were analyzed offline by manually tracing endocardial and epicardial boundaries of stacked contours. An excellent correlation in SV and mass between echo-derived values and displacement values was demonstrated and accompanied by high coefficients of determination (R2) in both groups (SV: Group A: R2 = 0.9461, Group B: R2 = 0.9811; Mass: Group A: R2 = 0.9223, Group B: R2 = 0.9602; all P <0.001). Bland-Altman analyses showed a slight overestimation in both groups for both SV and LV mass. Conclusions: Nongated 4DE was demonstrated to be feasible and that it could accurately define SV and ventricular mass for a fetal heart-sized LV model. (Echocardiography 2014;31:1138-1145).

KW - Fetal echocardiography

KW - Four-dimensional echocardiography

KW - Left ventricular mass

UR - http://www.scopus.com/inward/record.url?scp=84908227116&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84908227116&partnerID=8YFLogxK

U2 - 10.1111/echo.12520

DO - 10.1111/echo.12520

M3 - Article

C2 - 24460586

AN - SCOPUS:84908227116

VL - 31

SP - 1138

EP - 1145

JO - Echocardiography

JF - Echocardiography

SN - 0742-2822

IS - 9

ER -