Die CO 2-Messung im Atemgas

Translated title of the contribution: End-tidal CO 2 monitoring in emergency medicine

Ansgar Brambrink

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Currently, even in prehospital emergency medicine (PEM), continuous end-tidal CO 2 monitoring is frequently used as a sensitive and non-invasive technique in ventilated patients. Due to its central role, the continuous measurement of exhaled CO 2 provides immediate information about the status of three essential functions of the organism: ventilation, circulation, and metabolism. Methods: Recent literature, obtained by a computer-guided search (Winspirs(TM)), and product information of all currently available capnometry devices were reviewed in detail. Firstly, the theoretical background of different CO 2-measurement methods and techniques is described. Secondly, indications and specific implications for the out-of-hospital use of capnometry are discussed. Thirdly, different monitoring systems suitable for prehospital care are evaluated. Results: There are two basic principles to reliably determine end-tidal CO 2 (EtpCO 2) that can be realised in portable monitors: qualitative measurements with a paper indicator and quantitative measurements using nondispersive infrared spectroscopy. Capnography is a feature of more advanced units to provide the emergency physician with additional information by displaying EtpCO 2 values versus time. Multiple indications for capnometry in emergency situations are listed, all related to the evaluation of patient's ventilation, circulation, and metabolism. Specific implications regarding mobility, ease of use, patient hygiene and accuracy of measurements are mentioned. Five units, each representing a different type of CO 2 monitor, are described and evaluated for their use in PEM. Conclusions: Some current portable CO 2 monitors allow fast and reliable measurement of EtpCO 2 even in the out-of-hospital care of critically ill patients. However, the development of a new portable monitoring system comprising the three most important ventilation parameters (ventilation rate, EtpCO 2, and peripheral O 2 saturation) seems to be a promising step for the improvement of monitoring in out-of-hospital emergencies.

Original languageGerman
Pages (from-to)604-612
Number of pages9
JournalAnaesthesist
Volume46
Issue number7
DOIs
StatePublished - 1997
Externally publishedYes

Fingerprint

Emergency Medicine
Carbon Monoxide
Ventilation
Emergencies
Capnography
Hygiene
Critical Illness
Spectrum Analysis
Physicians
Equipment and Supplies

Keywords

  • anaesthesia
  • capnometry
  • controlled ventilation
  • emergency medicine
  • measurement methods
  • monitoring

ASJC Scopus subject areas

  • Anesthesiology and Pain Medicine

Cite this

Die CO 2-Messung im Atemgas. / Brambrink, Ansgar.

In: Anaesthesist, Vol. 46, No. 7, 1997, p. 604-612.

Research output: Contribution to journalArticle

Brambrink, A 1997, 'Die CO 2-Messung im Atemgas', Anaesthesist, vol. 46, no. 7, pp. 604-612. https://doi.org/10.1007/s001010050444
Brambrink, Ansgar. / Die CO 2-Messung im Atemgas. In: Anaesthesist. 1997 ; Vol. 46, No. 7. pp. 604-612.
@article{3f7546eed1c644d0bc477858eb8373db,
title = "Die CO 2-Messung im Atemgas",
abstract = "Currently, even in prehospital emergency medicine (PEM), continuous end-tidal CO 2 monitoring is frequently used as a sensitive and non-invasive technique in ventilated patients. Due to its central role, the continuous measurement of exhaled CO 2 provides immediate information about the status of three essential functions of the organism: ventilation, circulation, and metabolism. Methods: Recent literature, obtained by a computer-guided search (Winspirs(TM)), and product information of all currently available capnometry devices were reviewed in detail. Firstly, the theoretical background of different CO 2-measurement methods and techniques is described. Secondly, indications and specific implications for the out-of-hospital use of capnometry are discussed. Thirdly, different monitoring systems suitable for prehospital care are evaluated. Results: There are two basic principles to reliably determine end-tidal CO 2 (EtpCO 2) that can be realised in portable monitors: qualitative measurements with a paper indicator and quantitative measurements using nondispersive infrared spectroscopy. Capnography is a feature of more advanced units to provide the emergency physician with additional information by displaying EtpCO 2 values versus time. Multiple indications for capnometry in emergency situations are listed, all related to the evaluation of patient's ventilation, circulation, and metabolism. Specific implications regarding mobility, ease of use, patient hygiene and accuracy of measurements are mentioned. Five units, each representing a different type of CO 2 monitor, are described and evaluated for their use in PEM. Conclusions: Some current portable CO 2 monitors allow fast and reliable measurement of EtpCO 2 even in the out-of-hospital care of critically ill patients. However, the development of a new portable monitoring system comprising the three most important ventilation parameters (ventilation rate, EtpCO 2, and peripheral O 2 saturation) seems to be a promising step for the improvement of monitoring in out-of-hospital emergencies.",
keywords = "anaesthesia, capnometry, controlled ventilation, emergency medicine, measurement methods, monitoring",
author = "Ansgar Brambrink",
year = "1997",
doi = "10.1007/s001010050444",
language = "German",
volume = "46",
pages = "604--612",
journal = "Der Anaesthesist",
issn = "0003-2417",
publisher = "Springer Verlag",
number = "7",

}

TY - JOUR

T1 - Die CO 2-Messung im Atemgas

AU - Brambrink, Ansgar

PY - 1997

Y1 - 1997

N2 - Currently, even in prehospital emergency medicine (PEM), continuous end-tidal CO 2 monitoring is frequently used as a sensitive and non-invasive technique in ventilated patients. Due to its central role, the continuous measurement of exhaled CO 2 provides immediate information about the status of three essential functions of the organism: ventilation, circulation, and metabolism. Methods: Recent literature, obtained by a computer-guided search (Winspirs(TM)), and product information of all currently available capnometry devices were reviewed in detail. Firstly, the theoretical background of different CO 2-measurement methods and techniques is described. Secondly, indications and specific implications for the out-of-hospital use of capnometry are discussed. Thirdly, different monitoring systems suitable for prehospital care are evaluated. Results: There are two basic principles to reliably determine end-tidal CO 2 (EtpCO 2) that can be realised in portable monitors: qualitative measurements with a paper indicator and quantitative measurements using nondispersive infrared spectroscopy. Capnography is a feature of more advanced units to provide the emergency physician with additional information by displaying EtpCO 2 values versus time. Multiple indications for capnometry in emergency situations are listed, all related to the evaluation of patient's ventilation, circulation, and metabolism. Specific implications regarding mobility, ease of use, patient hygiene and accuracy of measurements are mentioned. Five units, each representing a different type of CO 2 monitor, are described and evaluated for their use in PEM. Conclusions: Some current portable CO 2 monitors allow fast and reliable measurement of EtpCO 2 even in the out-of-hospital care of critically ill patients. However, the development of a new portable monitoring system comprising the three most important ventilation parameters (ventilation rate, EtpCO 2, and peripheral O 2 saturation) seems to be a promising step for the improvement of monitoring in out-of-hospital emergencies.

AB - Currently, even in prehospital emergency medicine (PEM), continuous end-tidal CO 2 monitoring is frequently used as a sensitive and non-invasive technique in ventilated patients. Due to its central role, the continuous measurement of exhaled CO 2 provides immediate information about the status of three essential functions of the organism: ventilation, circulation, and metabolism. Methods: Recent literature, obtained by a computer-guided search (Winspirs(TM)), and product information of all currently available capnometry devices were reviewed in detail. Firstly, the theoretical background of different CO 2-measurement methods and techniques is described. Secondly, indications and specific implications for the out-of-hospital use of capnometry are discussed. Thirdly, different monitoring systems suitable for prehospital care are evaluated. Results: There are two basic principles to reliably determine end-tidal CO 2 (EtpCO 2) that can be realised in portable monitors: qualitative measurements with a paper indicator and quantitative measurements using nondispersive infrared spectroscopy. Capnography is a feature of more advanced units to provide the emergency physician with additional information by displaying EtpCO 2 values versus time. Multiple indications for capnometry in emergency situations are listed, all related to the evaluation of patient's ventilation, circulation, and metabolism. Specific implications regarding mobility, ease of use, patient hygiene and accuracy of measurements are mentioned. Five units, each representing a different type of CO 2 monitor, are described and evaluated for their use in PEM. Conclusions: Some current portable CO 2 monitors allow fast and reliable measurement of EtpCO 2 even in the out-of-hospital care of critically ill patients. However, the development of a new portable monitoring system comprising the three most important ventilation parameters (ventilation rate, EtpCO 2, and peripheral O 2 saturation) seems to be a promising step for the improvement of monitoring in out-of-hospital emergencies.

KW - anaesthesia

KW - capnometry

KW - controlled ventilation

KW - emergency medicine

KW - measurement methods

KW - monitoring

UR - http://www.scopus.com/inward/record.url?scp=0031182266&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031182266&partnerID=8YFLogxK

U2 - 10.1007/s001010050444

DO - 10.1007/s001010050444

M3 - Article

C2 - 9304362

AN - SCOPUS:0031182266

VL - 46

SP - 604

EP - 612

JO - Der Anaesthesist

JF - Der Anaesthesist

SN - 0003-2417

IS - 7

ER -