Electrochemical attack and corrosion of platinum electrodes in dielectrophoretic diagnostic devices

Daniel P. Heineck, Benjamin Sarno, Sejung Kim, Michael Heller

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

Though the advances in microelectronic device fabrication have realized new capabilities in integrated analytical and diagnostic platforms, there are still notable limitations in point-of-care sample preparation. AC electrokinetic devices, especially those leveraging dielectrophoresis (DEP), have shown potential to solve these limitations and allow for sample-to-answer in a single point-of-care device. However, when working directly with whole blood or other high conductance (~ 1 S/m) biological fluids, the aggressive electrochemical conditions created by the electrode can fundamentally limit the device operation. In this study, platinum wire-based electrode devices spanning circular polytetrafluorethylene (PTFE) wells and a planar microarray device with sputtered platinum electrodes were tested in plasma and PBS buffers of differing concentration across a wide range of frequencies and electric field intensities (AC voltages) to determine their respective safe regions of operation and to gain an understanding about the failure mechanisms of this class of device. At frequencies of 10 kHz and below, the upper bound of operation is the degradation of electrodes due to electrochemical attack by chlorine overcoming the native platinum oxide passivation. At higher frequencies, 100 kHz and above, the dielectric loss and subsequent heating of the buffer will boil before the electrodes suffer observable damage, due to the slow irreversible reaction kinetics. Effective dielectrophoretic capture of small biological particles at these frequencies is limited, and heat/oxidative denaturation of target material are a major concern. A new class of smaller devices, ones capable of high throughput at voltages low enough to maintain the integrity of the platinum passivation layer, is needed to mitigate these fundamental limitations.

Original languageEnglish (US)
Pages (from-to)3871-3880
Number of pages10
JournalAnalytical and Bioanalytical Chemistry
Volume412
Issue number16
DOIs
StatePublished - Jun 1 2020

Keywords

  • Corrosion
  • Dielectrophoresis
  • Electrochemistry
  • Electrokinetics
  • Liquid biopsy
  • Point-of-care

ASJC Scopus subject areas

  • Analytical Chemistry
  • Biochemistry

Fingerprint

Dive into the research topics of 'Electrochemical attack and corrosion of platinum electrodes in dielectrophoretic diagnostic devices'. Together they form a unique fingerprint.

Cite this