Electric field directed assembly of high-density microbead arrays

Kristopher D. Barbee, Alexander P. Hsiao, Michael (Mike) Heller, Xiaohua Huang

Research output: Contribution to journalArticle

29 Citations (Scopus)

Abstract

We report a method for rapid, electric field directed assembly of high-density protein-conjugated microbead arrays. Photolithography is used to fabricate an array of micron to sub-micron-scale wells in an epoxy-based photoresist on a silicon wafer coated with a thin gold film, which serves as the primary electrode. A thin gasket is used to form a microfluidic chamber between the wafer and a glass coverslip coated with indium-tin oxide, which serves as the counter electrode. Streptavidin-conjugated microbeads suspended in a low conductance buffer are introduced into the chamber and directed into the wells via electrophoresis by applying a series of low voltage electrical pulses across the electrodes. Hundreds of millions of microbeads can be permanently assembled on these arrays in as little as 30 seconds and the process can be monitored in real time using epifluorescence microscopy. The binding of the microbeads to the gold film is robust and occurs through electrochemically induced gold-protein interactions, which allows excess beads to be washed away or recycled. The well and bead sizes are chosen such that only one bead can be captured in each well. Filling efficiencies greater than 99.9% have been demonstrated across wafer-scale arrays with densities as high as 69 million beads per cm 2. Potential applications for this technology include the assembly of DNA arrays for high-throughput genome sequencing and antibody arrays for proteomic studies. Following array assembly, this device may also be used to enhance the concentration-dependent processes of various assays through the accelerated transport of molecules using electric fields.

Original languageEnglish (US)
Pages (from-to)3268-3274
Number of pages7
JournalLab on a Chip
Volume9
Issue number22
DOIs
StatePublished - Jan 1 2009
Externally publishedYes

Fingerprint

Microspheres
Gold
Electric fields
Electrodes
Proteins
Streptavidin
Photolithography
Photoresists
Electrophoresis
Tin oxides
Silicon wafers
Microfluidics
Antibodies
Indium
Assays
Microscopic examination
Buffers
DNA
Silicon
Genes

ASJC Scopus subject areas

  • Bioengineering
  • Biochemistry
  • Chemistry(all)
  • Biomedical Engineering

Cite this

Electric field directed assembly of high-density microbead arrays. / Barbee, Kristopher D.; Hsiao, Alexander P.; Heller, Michael (Mike); Huang, Xiaohua.

In: Lab on a Chip, Vol. 9, No. 22, 01.01.2009, p. 3268-3274.

Research output: Contribution to journalArticle

Barbee, Kristopher D. ; Hsiao, Alexander P. ; Heller, Michael (Mike) ; Huang, Xiaohua. / Electric field directed assembly of high-density microbead arrays. In: Lab on a Chip. 2009 ; Vol. 9, No. 22. pp. 3268-3274.
@article{4f52eb5b7e2944adaa9ae015188828ed,
title = "Electric field directed assembly of high-density microbead arrays",
abstract = "We report a method for rapid, electric field directed assembly of high-density protein-conjugated microbead arrays. Photolithography is used to fabricate an array of micron to sub-micron-scale wells in an epoxy-based photoresist on a silicon wafer coated with a thin gold film, which serves as the primary electrode. A thin gasket is used to form a microfluidic chamber between the wafer and a glass coverslip coated with indium-tin oxide, which serves as the counter electrode. Streptavidin-conjugated microbeads suspended in a low conductance buffer are introduced into the chamber and directed into the wells via electrophoresis by applying a series of low voltage electrical pulses across the electrodes. Hundreds of millions of microbeads can be permanently assembled on these arrays in as little as 30 seconds and the process can be monitored in real time using epifluorescence microscopy. The binding of the microbeads to the gold film is robust and occurs through electrochemically induced gold-protein interactions, which allows excess beads to be washed away or recycled. The well and bead sizes are chosen such that only one bead can be captured in each well. Filling efficiencies greater than 99.9{\%} have been demonstrated across wafer-scale arrays with densities as high as 69 million beads per cm 2. Potential applications for this technology include the assembly of DNA arrays for high-throughput genome sequencing and antibody arrays for proteomic studies. Following array assembly, this device may also be used to enhance the concentration-dependent processes of various assays through the accelerated transport of molecules using electric fields.",
author = "Barbee, {Kristopher D.} and Hsiao, {Alexander P.} and Heller, {Michael (Mike)} and Xiaohua Huang",
year = "2009",
month = "1",
day = "1",
doi = "10.1039/b912876j",
language = "English (US)",
volume = "9",
pages = "3268--3274",
journal = "Lab on a Chip - Miniaturisation for Chemistry and Biology",
issn = "1473-0197",
publisher = "Royal Society of Chemistry",
number = "22",

}

TY - JOUR

T1 - Electric field directed assembly of high-density microbead arrays

AU - Barbee, Kristopher D.

AU - Hsiao, Alexander P.

AU - Heller, Michael (Mike)

AU - Huang, Xiaohua

PY - 2009/1/1

Y1 - 2009/1/1

N2 - We report a method for rapid, electric field directed assembly of high-density protein-conjugated microbead arrays. Photolithography is used to fabricate an array of micron to sub-micron-scale wells in an epoxy-based photoresist on a silicon wafer coated with a thin gold film, which serves as the primary electrode. A thin gasket is used to form a microfluidic chamber between the wafer and a glass coverslip coated with indium-tin oxide, which serves as the counter electrode. Streptavidin-conjugated microbeads suspended in a low conductance buffer are introduced into the chamber and directed into the wells via electrophoresis by applying a series of low voltage electrical pulses across the electrodes. Hundreds of millions of microbeads can be permanently assembled on these arrays in as little as 30 seconds and the process can be monitored in real time using epifluorescence microscopy. The binding of the microbeads to the gold film is robust and occurs through electrochemically induced gold-protein interactions, which allows excess beads to be washed away or recycled. The well and bead sizes are chosen such that only one bead can be captured in each well. Filling efficiencies greater than 99.9% have been demonstrated across wafer-scale arrays with densities as high as 69 million beads per cm 2. Potential applications for this technology include the assembly of DNA arrays for high-throughput genome sequencing and antibody arrays for proteomic studies. Following array assembly, this device may also be used to enhance the concentration-dependent processes of various assays through the accelerated transport of molecules using electric fields.

AB - We report a method for rapid, electric field directed assembly of high-density protein-conjugated microbead arrays. Photolithography is used to fabricate an array of micron to sub-micron-scale wells in an epoxy-based photoresist on a silicon wafer coated with a thin gold film, which serves as the primary electrode. A thin gasket is used to form a microfluidic chamber between the wafer and a glass coverslip coated with indium-tin oxide, which serves as the counter electrode. Streptavidin-conjugated microbeads suspended in a low conductance buffer are introduced into the chamber and directed into the wells via electrophoresis by applying a series of low voltage electrical pulses across the electrodes. Hundreds of millions of microbeads can be permanently assembled on these arrays in as little as 30 seconds and the process can be monitored in real time using epifluorescence microscopy. The binding of the microbeads to the gold film is robust and occurs through electrochemically induced gold-protein interactions, which allows excess beads to be washed away or recycled. The well and bead sizes are chosen such that only one bead can be captured in each well. Filling efficiencies greater than 99.9% have been demonstrated across wafer-scale arrays with densities as high as 69 million beads per cm 2. Potential applications for this technology include the assembly of DNA arrays for high-throughput genome sequencing and antibody arrays for proteomic studies. Following array assembly, this device may also be used to enhance the concentration-dependent processes of various assays through the accelerated transport of molecules using electric fields.

UR - http://www.scopus.com/inward/record.url?scp=72049120410&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=72049120410&partnerID=8YFLogxK

U2 - 10.1039/b912876j

DO - 10.1039/b912876j

M3 - Article

VL - 9

SP - 3268

EP - 3274

JO - Lab on a Chip - Miniaturisation for Chemistry and Biology

JF - Lab on a Chip - Miniaturisation for Chemistry and Biology

SN - 1473-0197

IS - 22

ER -