T1 - Diagnostic utility of a novel leadless arrhythmia monitoring device
AU - Turakhia, Mintu P.
AU - Hoang, Donald D.
AU - Zimetbaum, Peter
AU - Miller, Jared D.
AU - Froelicher, Victor F.
AU - Kumar, Uday N.
AU - Xu, Xiangyan
AU - Yang, Felix
AU - Heidenreich, Paul A.
N1 - Funding Information:
This project was supported by a grant from iRhythm Technologies, Inc. (San Francisco, CA). Dr. Turakhia is supported by Veterans Health Services Research and Development Career Development Award CDA09027-1 (Washington, DC) and American Heart Association National Scientist Development grant 09SDG2250647 (Dallas, Texas).
PY - 2013/8/15
Y1 - 2013/8/15
N2 - Although extending the duration of ambulatory electrocardiographic monitoring beyond 24 to 48 hours can improve the detection of arrhythmias, lead-based (Holter) monitors might be limited by patient compliance and other factors. We, therefore, evaluated compliance, analyzable signal time, interval to arrhythmia detection, and diagnostic yield of the Zio Patch, a novel leadless, electrocardiographic monitoring device in 26,751 consecutive patients. The mean wear time was 7.6 ± 3.6 days, and the median analyzable time was 99% of the total wear time. Among the patients with detected arrhythmias (60.3% of all patients), 29.9% had their first arrhythmia and 51.1% had their first symptom-triggered arrhythmia occur after the initial 48-hour period. Compared with the first 48 hours of monitoring, the overall diagnostic yield was greater when data from the entire Zio Patch wear duration were included for any arrhythmia (62.2% vs 43.9%, p <0.0001) and for any symptomatic arrhythmia (9.7% vs 4.4%, p <0.0001). For paroxysmal atrial fibrillation (AF), the mean interval to the first detection of AF was inversely proportional to the total AF burden, with an increasing proportion occurring after 48 hours (11.2%, 10.5%, 20.8%, and 38.0% for an AF burden of 51% to 75%, 26% to 50%, 1% to 25%, and <1%, respectively). In conclusion, extended monitoring with the Zio Patch for ≤14 days is feasible, with high patient compliance, a high analyzable signal time, and an incremental diagnostic yield beyond 48 hours for all arrhythmia types. These findings could have significant implications for device selection, monitoring duration, and care pathways for arrhythmia evaluation and AF surveillance.
AB - Although extending the duration of ambulatory electrocardiographic monitoring beyond 24 to 48 hours can improve the detection of arrhythmias, lead-based (Holter) monitors might be limited by patient compliance and other factors. We, therefore, evaluated compliance, analyzable signal time, interval to arrhythmia detection, and diagnostic yield of the Zio Patch, a novel leadless, electrocardiographic monitoring device in 26,751 consecutive patients. The mean wear time was 7.6 ± 3.6 days, and the median analyzable time was 99% of the total wear time. Among the patients with detected arrhythmias (60.3% of all patients), 29.9% had their first arrhythmia and 51.1% had their first symptom-triggered arrhythmia occur after the initial 48-hour period. Compared with the first 48 hours of monitoring, the overall diagnostic yield was greater when data from the entire Zio Patch wear duration were included for any arrhythmia (62.2% vs 43.9%, p <0.0001) and for any symptomatic arrhythmia (9.7% vs 4.4%, p <0.0001). For paroxysmal atrial fibrillation (AF), the mean interval to the first detection of AF was inversely proportional to the total AF burden, with an increasing proportion occurring after 48 hours (11.2%, 10.5%, 20.8%, and 38.0% for an AF burden of 51% to 75%, 26% to 50%, 1% to 25%, and <1%, respectively). In conclusion, extended monitoring with the Zio Patch for ≤14 days is feasible, with high patient compliance, a high analyzable signal time, and an incremental diagnostic yield beyond 48 hours for all arrhythmia types. These findings could have significant implications for device selection, monitoring duration, and care pathways for arrhythmia evaluation and AF surveillance.
UR - http://www.scopus.com/inward/record.url?scp=84881191036&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84881191036&partnerID=8YFLogxK
U2 - 10.1016/j.amjcard.2013.04.017
DO - 10.1016/j.amjcard.2013.04.017
M3 - Article
C2 - 23672988
AN - SCOPUS:84881191036
SN - 0002-9149
VL - 112
SP - 520
EP - 524
JO - American Journal of Cardiology
JF - American Journal of Cardiology
IS - 4
ER -