TY - JOUR
T1 - Diagnostic accuracy of tests to detect hepatitis B surface antigen
T2 - A systematic review of the literature and meta-analysis
AU - Amini, Ali
AU - Varsaneux, Olivia
AU - Kelly, Helen
AU - Tang, Weiming
AU - Chen, Wen
AU - Boeras, Debrah I.
AU - Falconer, Jane
AU - Tucker, Joseph D.
AU - Chou, Roger
AU - Ishizaki, Azumi
AU - Easterbrook, Philippa
AU - Peeling, Rosanna W.
N1 - Funding Information:
This work was supported by funding from the World Health Organization to RP at LSHTM, National Institutes of Health National Institute of Allergy and Infectious Diseases 1R01AI114310–01 to JT, and UNC-South China STD Research Training Centre Fogarty International Centre 1D43TW009532–01 to JT. Publication charges for this article have been funded by the World Health Organization.
Publisher Copyright:
© 2017 World Health Organization.
PY - 2017/11/1
Y1 - 2017/11/1
N2 - Background: Chronic Hepatitis B Virus (HBV) infection is characterised by the persistence of hepatitis B surface antigen (HBsAg). Expanding HBV diagnosis and treatment programmes into low resource settings will require high quality but inexpensive rapid diagnostic tests (RDTs) in addition to laboratory-based enzyme immunoassays (EIAs) to detect HBsAg. The purpose of this review is to assess the clinical accuracy of available diagnostic tests to detect HBsAg to inform recommendations on testing strategies in 2017 WHO hepatitis testing guidelines. Methods: The systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines using 9 databases. Two reviewers independently extracted data according to a pre-specified plan and evaluated study quality. Meta-analysis was performed. HBsAg diagnostic accuracy of rapid diagnostic tests (RDTs) was compared to enzyme immunoassay (EIA) and nucleic-acid test (NAT) reference standards. Subanalyses were performed to determine accuracy among brands, HIV-status and specimen type. Results: Of the 40 studies that met the inclusion criteria, 33 compared RDTs and/or EIAs against EIAs and 7 against NATs as reference standards. Thirty studies assessed diagnostic accuracy of 33 brands of RDTs in 23,716 individuals from 23 countries using EIA as the reference standard. The pooled sensitivity and specificity were 90.0% (95% CI: 89.1, 90.8) and 99.5% (95% CI: 99.4, 99.5) respectively, but accuracy varied widely among brands. Accuracy did not differ significantly whether serum, plasma, venous or capillary whole blood was used. Pooled sensitivity of RDTs in 5 studies of HIV-positive persons was lower at 72.3% (95% CI: 67.9, 76.4) compared to that in HIV-negative persons, but specificity remained high. Five studies evaluated 8 EIAs against a chemiluminescence immunoassay reference standard with a pooled sensitivity and specificity of 88.9% (95% CI: 87.0, 90.6) and 98.4% (95% CI: 97.8, 98.8), respectively. Accuracy of both RDTs and EIAs using a NAT reference were generally lower, especially amongst HIV-positive cohorts. Conclusions: HBsAg RDTs have good sensitivity and excellent specificity compared to laboratory immunoassays as a reference standard. Sensitivity of HBsAg RDTs may be lower in HIV infected individuals.
AB - Background: Chronic Hepatitis B Virus (HBV) infection is characterised by the persistence of hepatitis B surface antigen (HBsAg). Expanding HBV diagnosis and treatment programmes into low resource settings will require high quality but inexpensive rapid diagnostic tests (RDTs) in addition to laboratory-based enzyme immunoassays (EIAs) to detect HBsAg. The purpose of this review is to assess the clinical accuracy of available diagnostic tests to detect HBsAg to inform recommendations on testing strategies in 2017 WHO hepatitis testing guidelines. Methods: The systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines using 9 databases. Two reviewers independently extracted data according to a pre-specified plan and evaluated study quality. Meta-analysis was performed. HBsAg diagnostic accuracy of rapid diagnostic tests (RDTs) was compared to enzyme immunoassay (EIA) and nucleic-acid test (NAT) reference standards. Subanalyses were performed to determine accuracy among brands, HIV-status and specimen type. Results: Of the 40 studies that met the inclusion criteria, 33 compared RDTs and/or EIAs against EIAs and 7 against NATs as reference standards. Thirty studies assessed diagnostic accuracy of 33 brands of RDTs in 23,716 individuals from 23 countries using EIA as the reference standard. The pooled sensitivity and specificity were 90.0% (95% CI: 89.1, 90.8) and 99.5% (95% CI: 99.4, 99.5) respectively, but accuracy varied widely among brands. Accuracy did not differ significantly whether serum, plasma, venous or capillary whole blood was used. Pooled sensitivity of RDTs in 5 studies of HIV-positive persons was lower at 72.3% (95% CI: 67.9, 76.4) compared to that in HIV-negative persons, but specificity remained high. Five studies evaluated 8 EIAs against a chemiluminescence immunoassay reference standard with a pooled sensitivity and specificity of 88.9% (95% CI: 87.0, 90.6) and 98.4% (95% CI: 97.8, 98.8), respectively. Accuracy of both RDTs and EIAs using a NAT reference were generally lower, especially amongst HIV-positive cohorts. Conclusions: HBsAg RDTs have good sensitivity and excellent specificity compared to laboratory immunoassays as a reference standard. Sensitivity of HBsAg RDTs may be lower in HIV infected individuals.
KW - CMIA
KW - Diagnostic accuracy
KW - Diagnostic tests
KW - Enzyme immunoassays
KW - Hepatitis B virus
KW - MEIA
KW - Rapid diagnostic tests
UR - http://www.scopus.com/inward/record.url?scp=85017499565&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85017499565&partnerID=8YFLogxK
U2 - 10.1186/s12879-017-2772-3
DO - 10.1186/s12879-017-2772-3
M3 - Article
C2 - 29143619
AN - SCOPUS:85017499565
SN - 1471-2334
VL - 17
JO - BMC Infectious Diseases
JF - BMC Infectious Diseases
M1 - 698
ER -