Determination of the unit size of the corneal endothelial cell mosaic from Fourier component image analysis

M. J. Doughty, M. Spiteri, David Dilts

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

Scanning electron micrographs were taken of the central region of the corneal endothelium of cows (Holstein). The cells were outlined and an image overlay generated of approximately 100 cells. Via a Windows-based scanning system, the overlay was subjected to a two-dimensional Fourier transform on a Unix-based system. A custom algorithm was developed (IRIS) to sequentially analyse the Fourier transform pattern. The transform and resultant harmonics spectrum were compared to those obtained from artificial cell mosaics generated from uniform sized symmetrical hexagons. The position, width, and height of the 1st harmonic component of the frequency distribution appears to be derived from average cell-cell border distances across the image. The radial position of the 1st harmonic is inversely related to the unit cell size in the mosaic, i.e. the dominant cell size. The application of such techniques to cell mosaic analyses is discussed.

Original languageEnglish (US)
Pages (from-to)229-238
Number of pages10
JournalTissue and Cell
Volume29
Issue number2
StatePublished - 1997
Externally publishedYes

Fingerprint

endothelial cells
Endothelial Cells
image analysis
Fourier Analysis
Cell Size
cells
Artificial Cells
Corneal Endothelium
endothelium
Electrons
Holstein
electrons
cows

Keywords

  • Bovine
  • Cornea
  • Image analysis

ASJC Scopus subject areas

  • Insect Science
  • Cell Biology

Cite this

Determination of the unit size of the corneal endothelial cell mosaic from Fourier component image analysis. / Doughty, M. J.; Spiteri, M.; Dilts, David.

In: Tissue and Cell, Vol. 29, No. 2, 1997, p. 229-238.

Research output: Contribution to journalArticle

Doughty, M. J. ; Spiteri, M. ; Dilts, David. / Determination of the unit size of the corneal endothelial cell mosaic from Fourier component image analysis. In: Tissue and Cell. 1997 ; Vol. 29, No. 2. pp. 229-238.
@article{81ded3a149ff4562b3a1d49f99eb0f13,
title = "Determination of the unit size of the corneal endothelial cell mosaic from Fourier component image analysis",
abstract = "Scanning electron micrographs were taken of the central region of the corneal endothelium of cows (Holstein). The cells were outlined and an image overlay generated of approximately 100 cells. Via a Windows-based scanning system, the overlay was subjected to a two-dimensional Fourier transform on a Unix-based system. A custom algorithm was developed (IRIS) to sequentially analyse the Fourier transform pattern. The transform and resultant harmonics spectrum were compared to those obtained from artificial cell mosaics generated from uniform sized symmetrical hexagons. The position, width, and height of the 1st harmonic component of the frequency distribution appears to be derived from average cell-cell border distances across the image. The radial position of the 1st harmonic is inversely related to the unit cell size in the mosaic, i.e. the dominant cell size. The application of such techniques to cell mosaic analyses is discussed.",
keywords = "Bovine, Cornea, Image analysis",
author = "Doughty, {M. J.} and M. Spiteri and David Dilts",
year = "1997",
language = "English (US)",
volume = "29",
pages = "229--238",
journal = "Tissue and Cell",
issn = "0040-8166",
publisher = "Churchill Livingstone",
number = "2",

}

TY - JOUR

T1 - Determination of the unit size of the corneal endothelial cell mosaic from Fourier component image analysis

AU - Doughty, M. J.

AU - Spiteri, M.

AU - Dilts, David

PY - 1997

Y1 - 1997

N2 - Scanning electron micrographs were taken of the central region of the corneal endothelium of cows (Holstein). The cells were outlined and an image overlay generated of approximately 100 cells. Via a Windows-based scanning system, the overlay was subjected to a two-dimensional Fourier transform on a Unix-based system. A custom algorithm was developed (IRIS) to sequentially analyse the Fourier transform pattern. The transform and resultant harmonics spectrum were compared to those obtained from artificial cell mosaics generated from uniform sized symmetrical hexagons. The position, width, and height of the 1st harmonic component of the frequency distribution appears to be derived from average cell-cell border distances across the image. The radial position of the 1st harmonic is inversely related to the unit cell size in the mosaic, i.e. the dominant cell size. The application of such techniques to cell mosaic analyses is discussed.

AB - Scanning electron micrographs were taken of the central region of the corneal endothelium of cows (Holstein). The cells were outlined and an image overlay generated of approximately 100 cells. Via a Windows-based scanning system, the overlay was subjected to a two-dimensional Fourier transform on a Unix-based system. A custom algorithm was developed (IRIS) to sequentially analyse the Fourier transform pattern. The transform and resultant harmonics spectrum were compared to those obtained from artificial cell mosaics generated from uniform sized symmetrical hexagons. The position, width, and height of the 1st harmonic component of the frequency distribution appears to be derived from average cell-cell border distances across the image. The radial position of the 1st harmonic is inversely related to the unit cell size in the mosaic, i.e. the dominant cell size. The application of such techniques to cell mosaic analyses is discussed.

KW - Bovine

KW - Cornea

KW - Image analysis

UR - http://www.scopus.com/inward/record.url?scp=0030975487&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030975487&partnerID=8YFLogxK

M3 - Article

VL - 29

SP - 229

EP - 238

JO - Tissue and Cell

JF - Tissue and Cell

SN - 0040-8166

IS - 2

ER -