Degree of conversion, depth of cure, and color stability of experimental dental composite formulated with camphorquinone and phenanthrenequinone photoinitiators

Pedro Paulo A C Albuquerque, Marcusv L. Bertolo, Larissa M A Cavalcante, Carmem Pfeifer, Luis F S Schneider

Research output: Contribution to journalArticle

17 Citations (Scopus)

Abstract

Abstract Purpose This study evaluated the applicability of 9,10-phenanthrenequinone (PQ) in experimental dental composites. Materials Camphorquinone (CQ), PQ, ethyl 4-N,N-dimethylaminobenzoate (EDMAB) and diphenyliodonium salt (DPI) were employed. A mixture of 2,2-bis(4-[2-hydroxy-3-methacryloxypropoxy]phenyl)-propane/triethylene glycol dimethacrylate (60:40%) and silanated glass filler at 60% were used. A two-peak-based light-emitting diode (LED) was used. Methods The photoinitiator absorption and the light emission spectra were determined by a Ultraviolet-visible spectroscopy and a spectroradiometer, respectively. Relative photon absorption (RPabs) was calculated. Fourier-transformed infrared spectroscopy analysis was used to determine the degree of conversion (DC). The optical properties were determined with a spectrophotometer. Depth of cure was assessed from adapted International Organization for Standardization (ISO) 4049. Results were analyzed with descriptive analysis, analysis of variance, and Tukey's test (α = 5%). Results PQ showed higher RPabs than CQ. Regarding the DC, CQ + EDMAB (control), CQ + EDMAB + DPI, PQ + DPI, and PQ + EDMAB + DPI produced statistically similar results. Groups formulated with CQ presented higher depth of cure. Only the group formulated with CQ + EDMAB presented satisfactory color stability (ΔE <3.3). Conclusion PQ presented higher RPabs than CQ and it was able to produce DC similar to CQ + EDMAB, when used with DPI. However, groups formulated with PQ produced lower depth of cure, greater yellowing, and less color stability than the traditional combination CQ and amine. Clinical Significance Although research with novel photoinitiator systems should be encouraged, the traditional camphorquinone and amine pair remains as a reliable combination for the formulation of dental composites.

Original languageEnglish (US)
Pages (from-to)S49-S57
JournalJournal of Esthetic and Restorative Dentistry
Volume27
Issue numberS1
DOIs
StatePublished - Mar 1 2015

Fingerprint

Tooth
Color
Salts
Photons
Amines
Spectrum Analysis
camphorquinone
Light
Propane
9,10-phenanthrenequinone
Glass
ethyl 4-N,N-dimethylaminobenzoate
Analysis of Variance
diphenyliodonium
Research

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Degree of conversion, depth of cure, and color stability of experimental dental composite formulated with camphorquinone and phenanthrenequinone photoinitiators. / Albuquerque, Pedro Paulo A C; Bertolo, Marcusv L.; Cavalcante, Larissa M A; Pfeifer, Carmem; Schneider, Luis F S.

In: Journal of Esthetic and Restorative Dentistry, Vol. 27, No. S1, 01.03.2015, p. S49-S57.

Research output: Contribution to journalArticle

@article{5c8b13ed7b534c32963ee89623a21cb9,
title = "Degree of conversion, depth of cure, and color stability of experimental dental composite formulated with camphorquinone and phenanthrenequinone photoinitiators",
abstract = "Abstract Purpose This study evaluated the applicability of 9,10-phenanthrenequinone (PQ) in experimental dental composites. Materials Camphorquinone (CQ), PQ, ethyl 4-N,N-dimethylaminobenzoate (EDMAB) and diphenyliodonium salt (DPI) were employed. A mixture of 2,2-bis(4-[2-hydroxy-3-methacryloxypropoxy]phenyl)-propane/triethylene glycol dimethacrylate (60:40{\%}) and silanated glass filler at 60{\%} were used. A two-peak-based light-emitting diode (LED) was used. Methods The photoinitiator absorption and the light emission spectra were determined by a Ultraviolet-visible spectroscopy and a spectroradiometer, respectively. Relative photon absorption (RPabs) was calculated. Fourier-transformed infrared spectroscopy analysis was used to determine the degree of conversion (DC). The optical properties were determined with a spectrophotometer. Depth of cure was assessed from adapted International Organization for Standardization (ISO) 4049. Results were analyzed with descriptive analysis, analysis of variance, and Tukey's test (α = 5{\%}). Results PQ showed higher RPabs than CQ. Regarding the DC, CQ + EDMAB (control), CQ + EDMAB + DPI, PQ + DPI, and PQ + EDMAB + DPI produced statistically similar results. Groups formulated with CQ presented higher depth of cure. Only the group formulated with CQ + EDMAB presented satisfactory color stability (ΔE <3.3). Conclusion PQ presented higher RPabs than CQ and it was able to produce DC similar to CQ + EDMAB, when used with DPI. However, groups formulated with PQ produced lower depth of cure, greater yellowing, and less color stability than the traditional combination CQ and amine. Clinical Significance Although research with novel photoinitiator systems should be encouraged, the traditional camphorquinone and amine pair remains as a reliable combination for the formulation of dental composites.",
author = "Albuquerque, {Pedro Paulo A C} and Bertolo, {Marcusv L.} and Cavalcante, {Larissa M A} and Carmem Pfeifer and Schneider, {Luis F S}",
year = "2015",
month = "3",
day = "1",
doi = "10.1111/jerd.12131",
language = "English (US)",
volume = "27",
pages = "S49--S57",
journal = "Journal of Esthetic and Restorative Dentistry",
issn = "1496-4155",
publisher = "Wiley-Blackwell",
number = "S1",

}

TY - JOUR

T1 - Degree of conversion, depth of cure, and color stability of experimental dental composite formulated with camphorquinone and phenanthrenequinone photoinitiators

AU - Albuquerque, Pedro Paulo A C

AU - Bertolo, Marcusv L.

AU - Cavalcante, Larissa M A

AU - Pfeifer, Carmem

AU - Schneider, Luis F S

PY - 2015/3/1

Y1 - 2015/3/1

N2 - Abstract Purpose This study evaluated the applicability of 9,10-phenanthrenequinone (PQ) in experimental dental composites. Materials Camphorquinone (CQ), PQ, ethyl 4-N,N-dimethylaminobenzoate (EDMAB) and diphenyliodonium salt (DPI) were employed. A mixture of 2,2-bis(4-[2-hydroxy-3-methacryloxypropoxy]phenyl)-propane/triethylene glycol dimethacrylate (60:40%) and silanated glass filler at 60% were used. A two-peak-based light-emitting diode (LED) was used. Methods The photoinitiator absorption and the light emission spectra were determined by a Ultraviolet-visible spectroscopy and a spectroradiometer, respectively. Relative photon absorption (RPabs) was calculated. Fourier-transformed infrared spectroscopy analysis was used to determine the degree of conversion (DC). The optical properties were determined with a spectrophotometer. Depth of cure was assessed from adapted International Organization for Standardization (ISO) 4049. Results were analyzed with descriptive analysis, analysis of variance, and Tukey's test (α = 5%). Results PQ showed higher RPabs than CQ. Regarding the DC, CQ + EDMAB (control), CQ + EDMAB + DPI, PQ + DPI, and PQ + EDMAB + DPI produced statistically similar results. Groups formulated with CQ presented higher depth of cure. Only the group formulated with CQ + EDMAB presented satisfactory color stability (ΔE <3.3). Conclusion PQ presented higher RPabs than CQ and it was able to produce DC similar to CQ + EDMAB, when used with DPI. However, groups formulated with PQ produced lower depth of cure, greater yellowing, and less color stability than the traditional combination CQ and amine. Clinical Significance Although research with novel photoinitiator systems should be encouraged, the traditional camphorquinone and amine pair remains as a reliable combination for the formulation of dental composites.

AB - Abstract Purpose This study evaluated the applicability of 9,10-phenanthrenequinone (PQ) in experimental dental composites. Materials Camphorquinone (CQ), PQ, ethyl 4-N,N-dimethylaminobenzoate (EDMAB) and diphenyliodonium salt (DPI) were employed. A mixture of 2,2-bis(4-[2-hydroxy-3-methacryloxypropoxy]phenyl)-propane/triethylene glycol dimethacrylate (60:40%) and silanated glass filler at 60% were used. A two-peak-based light-emitting diode (LED) was used. Methods The photoinitiator absorption and the light emission spectra were determined by a Ultraviolet-visible spectroscopy and a spectroradiometer, respectively. Relative photon absorption (RPabs) was calculated. Fourier-transformed infrared spectroscopy analysis was used to determine the degree of conversion (DC). The optical properties were determined with a spectrophotometer. Depth of cure was assessed from adapted International Organization for Standardization (ISO) 4049. Results were analyzed with descriptive analysis, analysis of variance, and Tukey's test (α = 5%). Results PQ showed higher RPabs than CQ. Regarding the DC, CQ + EDMAB (control), CQ + EDMAB + DPI, PQ + DPI, and PQ + EDMAB + DPI produced statistically similar results. Groups formulated with CQ presented higher depth of cure. Only the group formulated with CQ + EDMAB presented satisfactory color stability (ΔE <3.3). Conclusion PQ presented higher RPabs than CQ and it was able to produce DC similar to CQ + EDMAB, when used with DPI. However, groups formulated with PQ produced lower depth of cure, greater yellowing, and less color stability than the traditional combination CQ and amine. Clinical Significance Although research with novel photoinitiator systems should be encouraged, the traditional camphorquinone and amine pair remains as a reliable combination for the formulation of dental composites.

UR - http://www.scopus.com/inward/record.url?scp=84928351421&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84928351421&partnerID=8YFLogxK

U2 - 10.1111/jerd.12131

DO - 10.1111/jerd.12131

M3 - Article

VL - 27

SP - S49-S57

JO - Journal of Esthetic and Restorative Dentistry

JF - Journal of Esthetic and Restorative Dentistry

SN - 1496-4155

IS - S1

ER -