Degradation of medical-grade polyurethane elastomers

The effect of hydrogen peroxide in vitro

G. F. Meijs, Simon McCarthy, E. Rizzardo, Y. C. Chen, R. C. Chatelier, A. Brandwood, K. Schindhelm

Research output: Contribution to journalArticle

54 Citations (Scopus)

Abstract

Treatment of Pellethane 2363-80A - a medical-grade poly(tetramethylene oxide)-based polyurethane elastomer - with 25% (w/w) hydrogen peroxide at 100°C for times ranging from 24 h to 336 h led to significant decreases in ultimate tensile properties and decreases in molecular weight, both at the surface and in the bulk. IR spectral changes were similar to those observed after degradation in vivo. Differential scanning calorimetry showed that hydrogen-peroxide-induced degradation was associated with greater order in the hard domain and greater mobility in the soft domain. Studies conducted with low-molecular-weight model compounds for the hard and soft segments confirmed that methylene groups adjacent to oxygen were susceptible toward oxidation. The extent of degradation of a series of commercial polyurethanes on treatment with hydrogen peroxide (25%, 24 h, 100°C) correlated well with their reported susceptibility to environmental stress cracking in vivo.

Original languageEnglish (US)
Pages (from-to)345-356
Number of pages12
JournalJournal of Biomedical Materials Research
Volume27
Issue number3
StatePublished - Mar 1993
Externally publishedYes

Fingerprint

Elastomers
Polyurethanes
Hydrogen peroxide
Hydrogen Peroxide
Degradation
Molecular weight
Tensile properties
Differential scanning calorimetry
Oxygen
Oxidation
Oxides

ASJC Scopus subject areas

  • Biomedical Engineering
  • Biomaterials

Cite this

Meijs, G. F., McCarthy, S., Rizzardo, E., Chen, Y. C., Chatelier, R. C., Brandwood, A., & Schindhelm, K. (1993). Degradation of medical-grade polyurethane elastomers: The effect of hydrogen peroxide in vitro. Journal of Biomedical Materials Research, 27(3), 345-356.

Degradation of medical-grade polyurethane elastomers : The effect of hydrogen peroxide in vitro. / Meijs, G. F.; McCarthy, Simon; Rizzardo, E.; Chen, Y. C.; Chatelier, R. C.; Brandwood, A.; Schindhelm, K.

In: Journal of Biomedical Materials Research, Vol. 27, No. 3, 03.1993, p. 345-356.

Research output: Contribution to journalArticle

Meijs, GF, McCarthy, S, Rizzardo, E, Chen, YC, Chatelier, RC, Brandwood, A & Schindhelm, K 1993, 'Degradation of medical-grade polyurethane elastomers: The effect of hydrogen peroxide in vitro', Journal of Biomedical Materials Research, vol. 27, no. 3, pp. 345-356.
Meijs GF, McCarthy S, Rizzardo E, Chen YC, Chatelier RC, Brandwood A et al. Degradation of medical-grade polyurethane elastomers: The effect of hydrogen peroxide in vitro. Journal of Biomedical Materials Research. 1993 Mar;27(3):345-356.
Meijs, G. F. ; McCarthy, Simon ; Rizzardo, E. ; Chen, Y. C. ; Chatelier, R. C. ; Brandwood, A. ; Schindhelm, K. / Degradation of medical-grade polyurethane elastomers : The effect of hydrogen peroxide in vitro. In: Journal of Biomedical Materials Research. 1993 ; Vol. 27, No. 3. pp. 345-356.
@article{902ed8b583ec4777b43be3345c247608,
title = "Degradation of medical-grade polyurethane elastomers: The effect of hydrogen peroxide in vitro",
abstract = "Treatment of Pellethane 2363-80A - a medical-grade poly(tetramethylene oxide)-based polyurethane elastomer - with 25{\%} (w/w) hydrogen peroxide at 100°C for times ranging from 24 h to 336 h led to significant decreases in ultimate tensile properties and decreases in molecular weight, both at the surface and in the bulk. IR spectral changes were similar to those observed after degradation in vivo. Differential scanning calorimetry showed that hydrogen-peroxide-induced degradation was associated with greater order in the hard domain and greater mobility in the soft domain. Studies conducted with low-molecular-weight model compounds for the hard and soft segments confirmed that methylene groups adjacent to oxygen were susceptible toward oxidation. The extent of degradation of a series of commercial polyurethanes on treatment with hydrogen peroxide (25{\%}, 24 h, 100°C) correlated well with their reported susceptibility to environmental stress cracking in vivo.",
author = "Meijs, {G. F.} and Simon McCarthy and E. Rizzardo and Chen, {Y. C.} and Chatelier, {R. C.} and A. Brandwood and K. Schindhelm",
year = "1993",
month = "3",
language = "English (US)",
volume = "27",
pages = "345--356",
journal = "Journal of Biomedical Materials Research - Part B Applied Biomaterials",
issn = "1552-4973",
publisher = "Heterocorporation",
number = "3",

}

TY - JOUR

T1 - Degradation of medical-grade polyurethane elastomers

T2 - The effect of hydrogen peroxide in vitro

AU - Meijs, G. F.

AU - McCarthy, Simon

AU - Rizzardo, E.

AU - Chen, Y. C.

AU - Chatelier, R. C.

AU - Brandwood, A.

AU - Schindhelm, K.

PY - 1993/3

Y1 - 1993/3

N2 - Treatment of Pellethane 2363-80A - a medical-grade poly(tetramethylene oxide)-based polyurethane elastomer - with 25% (w/w) hydrogen peroxide at 100°C for times ranging from 24 h to 336 h led to significant decreases in ultimate tensile properties and decreases in molecular weight, both at the surface and in the bulk. IR spectral changes were similar to those observed after degradation in vivo. Differential scanning calorimetry showed that hydrogen-peroxide-induced degradation was associated with greater order in the hard domain and greater mobility in the soft domain. Studies conducted with low-molecular-weight model compounds for the hard and soft segments confirmed that methylene groups adjacent to oxygen were susceptible toward oxidation. The extent of degradation of a series of commercial polyurethanes on treatment with hydrogen peroxide (25%, 24 h, 100°C) correlated well with their reported susceptibility to environmental stress cracking in vivo.

AB - Treatment of Pellethane 2363-80A - a medical-grade poly(tetramethylene oxide)-based polyurethane elastomer - with 25% (w/w) hydrogen peroxide at 100°C for times ranging from 24 h to 336 h led to significant decreases in ultimate tensile properties and decreases in molecular weight, both at the surface and in the bulk. IR spectral changes were similar to those observed after degradation in vivo. Differential scanning calorimetry showed that hydrogen-peroxide-induced degradation was associated with greater order in the hard domain and greater mobility in the soft domain. Studies conducted with low-molecular-weight model compounds for the hard and soft segments confirmed that methylene groups adjacent to oxygen were susceptible toward oxidation. The extent of degradation of a series of commercial polyurethanes on treatment with hydrogen peroxide (25%, 24 h, 100°C) correlated well with their reported susceptibility to environmental stress cracking in vivo.

UR - http://www.scopus.com/inward/record.url?scp=0027572105&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027572105&partnerID=8YFLogxK

M3 - Article

VL - 27

SP - 345

EP - 356

JO - Journal of Biomedical Materials Research - Part B Applied Biomaterials

JF - Journal of Biomedical Materials Research - Part B Applied Biomaterials

SN - 1552-4973

IS - 3

ER -