Consistency of leg extension power assessments in older men

The osteoporotic fractures in men (MrOS) study

Terri Blackwell, Peggy M. Cawthon, Lynn Marshall, Richard Brand

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

This study examined the consistency of the Nottingham power rig in assessing leg extension power in older men, assessed between different examiners with adjustment for the order of measurement (time) and clinic. Fifty-five men (mean, 73 yrs) enrolled in the Osteoporotic Fractures in Men Study had maximum leg extension power of each leg measured at baseline and remeasured 1 wk later. There was a significant effect of time (P <0.01). The second visit had an average increase in leg extension power (right leg, 14.2 W; left leg, 16.5 W). After accounting for the effect of time, a low coefficient of variation was observed between examiners (right leg 3.49%; left leg 3.46%). Data from the two time points corresponded reasonably well. The effect of time and fatigue should be considered when performing this measurement. The Nottingham power rig provided a reproducible measure of leg extension power in this multisite study of older men.

Original languageEnglish (US)
Pages (from-to)934-940
Number of pages7
JournalAmerican Journal of Physical Medicine and Rehabilitation
Volume88
Issue number11
DOIs
StatePublished - Nov 2009

Fingerprint

Osteoporotic Fractures
Leg
Fatigue

Keywords

  • Leg extension power
  • Muscle
  • Reliability
  • Strength

ASJC Scopus subject areas

  • Rehabilitation
  • Physical Therapy, Sports Therapy and Rehabilitation
  • Medicine(all)

Cite this

Consistency of leg extension power assessments in older men : The osteoporotic fractures in men (MrOS) study. / Blackwell, Terri; Cawthon, Peggy M.; Marshall, Lynn; Brand, Richard.

In: American Journal of Physical Medicine and Rehabilitation, Vol. 88, No. 11, 11.2009, p. 934-940.

Research output: Contribution to journalArticle

@article{dbf7fd52970149e781b951ed969516b8,
title = "Consistency of leg extension power assessments in older men: The osteoporotic fractures in men (MrOS) study",
abstract = "This study examined the consistency of the Nottingham power rig in assessing leg extension power in older men, assessed between different examiners with adjustment for the order of measurement (time) and clinic. Fifty-five men (mean, 73 yrs) enrolled in the Osteoporotic Fractures in Men Study had maximum leg extension power of each leg measured at baseline and remeasured 1 wk later. There was a significant effect of time (P <0.01). The second visit had an average increase in leg extension power (right leg, 14.2 W; left leg, 16.5 W). After accounting for the effect of time, a low coefficient of variation was observed between examiners (right leg 3.49{\%}; left leg 3.46{\%}). Data from the two time points corresponded reasonably well. The effect of time and fatigue should be considered when performing this measurement. The Nottingham power rig provided a reproducible measure of leg extension power in this multisite study of older men.",
keywords = "Leg extension power, Muscle, Reliability, Strength",
author = "Terri Blackwell and Cawthon, {Peggy M.} and Lynn Marshall and Richard Brand",
year = "2009",
month = "11",
doi = "10.1097/PHM.0b013e3181bbddfb",
language = "English (US)",
volume = "88",
pages = "934--940",
journal = "American Journal of Physical Medicine and Rehabilitation",
issn = "0894-9115",
publisher = "Lippincott Williams and Wilkins",
number = "11",

}

TY - JOUR

T1 - Consistency of leg extension power assessments in older men

T2 - The osteoporotic fractures in men (MrOS) study

AU - Blackwell, Terri

AU - Cawthon, Peggy M.

AU - Marshall, Lynn

AU - Brand, Richard

PY - 2009/11

Y1 - 2009/11

N2 - This study examined the consistency of the Nottingham power rig in assessing leg extension power in older men, assessed between different examiners with adjustment for the order of measurement (time) and clinic. Fifty-five men (mean, 73 yrs) enrolled in the Osteoporotic Fractures in Men Study had maximum leg extension power of each leg measured at baseline and remeasured 1 wk later. There was a significant effect of time (P <0.01). The second visit had an average increase in leg extension power (right leg, 14.2 W; left leg, 16.5 W). After accounting for the effect of time, a low coefficient of variation was observed between examiners (right leg 3.49%; left leg 3.46%). Data from the two time points corresponded reasonably well. The effect of time and fatigue should be considered when performing this measurement. The Nottingham power rig provided a reproducible measure of leg extension power in this multisite study of older men.

AB - This study examined the consistency of the Nottingham power rig in assessing leg extension power in older men, assessed between different examiners with adjustment for the order of measurement (time) and clinic. Fifty-five men (mean, 73 yrs) enrolled in the Osteoporotic Fractures in Men Study had maximum leg extension power of each leg measured at baseline and remeasured 1 wk later. There was a significant effect of time (P <0.01). The second visit had an average increase in leg extension power (right leg, 14.2 W; left leg, 16.5 W). After accounting for the effect of time, a low coefficient of variation was observed between examiners (right leg 3.49%; left leg 3.46%). Data from the two time points corresponded reasonably well. The effect of time and fatigue should be considered when performing this measurement. The Nottingham power rig provided a reproducible measure of leg extension power in this multisite study of older men.

KW - Leg extension power

KW - Muscle

KW - Reliability

KW - Strength

UR - http://www.scopus.com/inward/record.url?scp=74249099251&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=74249099251&partnerID=8YFLogxK

U2 - 10.1097/PHM.0b013e3181bbddfb

DO - 10.1097/PHM.0b013e3181bbddfb

M3 - Article

VL - 88

SP - 934

EP - 940

JO - American Journal of Physical Medicine and Rehabilitation

JF - American Journal of Physical Medicine and Rehabilitation

SN - 0894-9115

IS - 11

ER -