Cine magnetic resonance imaging for evaluation of anatomy and flow relations in infants and children with coarctation of the aorta

I. A. Simpson, K. J. Chung, R. F. Glass, David Sahn, F. S. Sherman, J. Hesselink

Research output: Contribution to journalArticle

89 Citations (Scopus)

Abstract

Sixteen cine magnetic resonance imaging (MRI) studies were performed in 14 patients aged 1 week to 17 years (mean age, 46 months), who had coarctation of the aorta confirmed at angiography or surgery. Conventional echocardiographic-gated MRI was first performed in axial and rotated sagittal views and was used to identify the slice locations for cine MRI. Cine MRI was performed by gradient-recalled acquisition in steady state with a 30° flip angle, 12-msec echo time, 22-msec pulse repetition time, and a 128 x 256 acquisition matrix. Coarctation anatomy was extremely well defined in all but one patient who had vascular clips at the coarctation repair site. The smallest descending aortic flow diameter on cine MRI showed excellent agreement with angiography (r = 0.90). Lucent jets of high-velocity flow through the site of coarctation were imaged in eight patients, and jet length correlated well with the angiographic severity of coarctation (r = -0.81). Two patients were restudied after surgery, and they exhibited excellent repair and normal flow patterns. Cine MRI provides high-resolution imaging of coarctation anatomy with a dynamic spatial and temporal visualization of flow and with excellent detail of vascular anatomy and flow both proximal and distal to the coarctation.

Original languageEnglish (US)
Pages (from-to)142-148
Number of pages7
JournalCirculation
Volume78
Issue number1
StatePublished - 1988
Externally publishedYes

Fingerprint

Cine Magnetic Resonance Imaging
Aortic Coarctation
Anatomy
Blood Vessels
Angiography
Surgical Instruments
Pulse
Magnetic Resonance Imaging

ASJC Scopus subject areas

  • Physiology
  • Cardiology and Cardiovascular Medicine

Cite this

Simpson, I. A., Chung, K. J., Glass, R. F., Sahn, D., Sherman, F. S., & Hesselink, J. (1988). Cine magnetic resonance imaging for evaluation of anatomy and flow relations in infants and children with coarctation of the aorta. Circulation, 78(1), 142-148.

Cine magnetic resonance imaging for evaluation of anatomy and flow relations in infants and children with coarctation of the aorta. / Simpson, I. A.; Chung, K. J.; Glass, R. F.; Sahn, David; Sherman, F. S.; Hesselink, J.

In: Circulation, Vol. 78, No. 1, 1988, p. 142-148.

Research output: Contribution to journalArticle

Simpson, IA, Chung, KJ, Glass, RF, Sahn, D, Sherman, FS & Hesselink, J 1988, 'Cine magnetic resonance imaging for evaluation of anatomy and flow relations in infants and children with coarctation of the aorta', Circulation, vol. 78, no. 1, pp. 142-148.
Simpson, I. A. ; Chung, K. J. ; Glass, R. F. ; Sahn, David ; Sherman, F. S. ; Hesselink, J. / Cine magnetic resonance imaging for evaluation of anatomy and flow relations in infants and children with coarctation of the aorta. In: Circulation. 1988 ; Vol. 78, No. 1. pp. 142-148.
@article{8085410e63c5493db463701c9740b1aa,
title = "Cine magnetic resonance imaging for evaluation of anatomy and flow relations in infants and children with coarctation of the aorta",
abstract = "Sixteen cine magnetic resonance imaging (MRI) studies were performed in 14 patients aged 1 week to 17 years (mean age, 46 months), who had coarctation of the aorta confirmed at angiography or surgery. Conventional echocardiographic-gated MRI was first performed in axial and rotated sagittal views and was used to identify the slice locations for cine MRI. Cine MRI was performed by gradient-recalled acquisition in steady state with a 30° flip angle, 12-msec echo time, 22-msec pulse repetition time, and a 128 x 256 acquisition matrix. Coarctation anatomy was extremely well defined in all but one patient who had vascular clips at the coarctation repair site. The smallest descending aortic flow diameter on cine MRI showed excellent agreement with angiography (r = 0.90). Lucent jets of high-velocity flow through the site of coarctation were imaged in eight patients, and jet length correlated well with the angiographic severity of coarctation (r = -0.81). Two patients were restudied after surgery, and they exhibited excellent repair and normal flow patterns. Cine MRI provides high-resolution imaging of coarctation anatomy with a dynamic spatial and temporal visualization of flow and with excellent detail of vascular anatomy and flow both proximal and distal to the coarctation.",
author = "Simpson, {I. A.} and Chung, {K. J.} and Glass, {R. F.} and David Sahn and Sherman, {F. S.} and J. Hesselink",
year = "1988",
language = "English (US)",
volume = "78",
pages = "142--148",
journal = "Circulation",
issn = "0009-7322",
publisher = "Lippincott Williams and Wilkins",
number = "1",

}

TY - JOUR

T1 - Cine magnetic resonance imaging for evaluation of anatomy and flow relations in infants and children with coarctation of the aorta

AU - Simpson, I. A.

AU - Chung, K. J.

AU - Glass, R. F.

AU - Sahn, David

AU - Sherman, F. S.

AU - Hesselink, J.

PY - 1988

Y1 - 1988

N2 - Sixteen cine magnetic resonance imaging (MRI) studies were performed in 14 patients aged 1 week to 17 years (mean age, 46 months), who had coarctation of the aorta confirmed at angiography or surgery. Conventional echocardiographic-gated MRI was first performed in axial and rotated sagittal views and was used to identify the slice locations for cine MRI. Cine MRI was performed by gradient-recalled acquisition in steady state with a 30° flip angle, 12-msec echo time, 22-msec pulse repetition time, and a 128 x 256 acquisition matrix. Coarctation anatomy was extremely well defined in all but one patient who had vascular clips at the coarctation repair site. The smallest descending aortic flow diameter on cine MRI showed excellent agreement with angiography (r = 0.90). Lucent jets of high-velocity flow through the site of coarctation were imaged in eight patients, and jet length correlated well with the angiographic severity of coarctation (r = -0.81). Two patients were restudied after surgery, and they exhibited excellent repair and normal flow patterns. Cine MRI provides high-resolution imaging of coarctation anatomy with a dynamic spatial and temporal visualization of flow and with excellent detail of vascular anatomy and flow both proximal and distal to the coarctation.

AB - Sixteen cine magnetic resonance imaging (MRI) studies were performed in 14 patients aged 1 week to 17 years (mean age, 46 months), who had coarctation of the aorta confirmed at angiography or surgery. Conventional echocardiographic-gated MRI was first performed in axial and rotated sagittal views and was used to identify the slice locations for cine MRI. Cine MRI was performed by gradient-recalled acquisition in steady state with a 30° flip angle, 12-msec echo time, 22-msec pulse repetition time, and a 128 x 256 acquisition matrix. Coarctation anatomy was extremely well defined in all but one patient who had vascular clips at the coarctation repair site. The smallest descending aortic flow diameter on cine MRI showed excellent agreement with angiography (r = 0.90). Lucent jets of high-velocity flow through the site of coarctation were imaged in eight patients, and jet length correlated well with the angiographic severity of coarctation (r = -0.81). Two patients were restudied after surgery, and they exhibited excellent repair and normal flow patterns. Cine MRI provides high-resolution imaging of coarctation anatomy with a dynamic spatial and temporal visualization of flow and with excellent detail of vascular anatomy and flow both proximal and distal to the coarctation.