Abstract

To study the effects of flow acceleration and high-velocity jets on the display characteristics of cine magnetic resonance imaging compared with color Doppler flow mapping, a custom-designed in vitro flow model was developed. This model consisted of a funnel segment tapering to an orifice (0.78 cm2) that leads into a confined receiving chamber with a second, discrete orifice (0.78 cm2) at its distal end. Cine magnetic resonance images obtained at varying flow rates (1.5 to 27.2 L/min) demonstrated loss of signal intensity throughout the tapering zone of spatial acceleration and a small zone of more marked signal loss immediately proximal to the second orifice (always

Original languageEnglish (US)
Pages (from-to)1165-1173
Number of pages9
JournalAmerican Heart Journal
Volume126
Issue number5
DOIs
StatePublished - 1993

Fingerprint

Cine Magnetic Resonance Imaging
Color
Magnetic Resonance Spectroscopy
In Vitro Techniques

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Cine magnetic resonance imaging and color Doppler flow mapping displays of flow velocity, spatial acceleration, and jet formation : A comparative in vitro study. / Simpson, Iain A.; Maciel, Benedito C.; Moises, Valdir; Shandas, Robin; Elias, William; Valdes-Cruz, Lilliam; Hesselink, John R.; Chung, Kyung J.; Sahn, David.

In: American Heart Journal, Vol. 126, No. 5, 1993, p. 1165-1173.

Research output: Contribution to journalArticle

Simpson, IA, Maciel, BC, Moises, V, Shandas, R, Elias, W, Valdes-Cruz, L, Hesselink, JR, Chung, KJ & Sahn, D 1993, 'Cine magnetic resonance imaging and color Doppler flow mapping displays of flow velocity, spatial acceleration, and jet formation: A comparative in vitro study', American Heart Journal, vol. 126, no. 5, pp. 1165-1173. https://doi.org/10.1016/0002-8703(93)90670-5
Simpson, Iain A. ; Maciel, Benedito C. ; Moises, Valdir ; Shandas, Robin ; Elias, William ; Valdes-Cruz, Lilliam ; Hesselink, John R. ; Chung, Kyung J. ; Sahn, David. / Cine magnetic resonance imaging and color Doppler flow mapping displays of flow velocity, spatial acceleration, and jet formation : A comparative in vitro study. In: American Heart Journal. 1993 ; Vol. 126, No. 5. pp. 1165-1173.
@article{cf0f23e8a2334003a7cf06d954111772,
title = "Cine magnetic resonance imaging and color Doppler flow mapping displays of flow velocity, spatial acceleration, and jet formation: A comparative in vitro study",
abstract = "To study the effects of flow acceleration and high-velocity jets on the display characteristics of cine magnetic resonance imaging compared with color Doppler flow mapping, a custom-designed in vitro flow model was developed. This model consisted of a funnel segment tapering to an orifice (0.78 cm2) that leads into a confined receiving chamber with a second, discrete orifice (0.78 cm2) at its distal end. Cine magnetic resonance images obtained at varying flow rates (1.5 to 27.2 L/min) demonstrated loss of signal intensity throughout the tapering zone of spatial acceleration and a small zone of more marked signal loss immediately proximal to the second orifice (always",
author = "Simpson, {Iain A.} and Maciel, {Benedito C.} and Valdir Moises and Robin Shandas and William Elias and Lilliam Valdes-Cruz and Hesselink, {John R.} and Chung, {Kyung J.} and David Sahn",
year = "1993",
doi = "10.1016/0002-8703(93)90670-5",
language = "English (US)",
volume = "126",
pages = "1165--1173",
journal = "American Heart Journal",
issn = "0002-8703",
publisher = "Mosby Inc.",
number = "5",

}

TY - JOUR

T1 - Cine magnetic resonance imaging and color Doppler flow mapping displays of flow velocity, spatial acceleration, and jet formation

T2 - A comparative in vitro study

AU - Simpson, Iain A.

AU - Maciel, Benedito C.

AU - Moises, Valdir

AU - Shandas, Robin

AU - Elias, William

AU - Valdes-Cruz, Lilliam

AU - Hesselink, John R.

AU - Chung, Kyung J.

AU - Sahn, David

PY - 1993

Y1 - 1993

N2 - To study the effects of flow acceleration and high-velocity jets on the display characteristics of cine magnetic resonance imaging compared with color Doppler flow mapping, a custom-designed in vitro flow model was developed. This model consisted of a funnel segment tapering to an orifice (0.78 cm2) that leads into a confined receiving chamber with a second, discrete orifice (0.78 cm2) at its distal end. Cine magnetic resonance images obtained at varying flow rates (1.5 to 27.2 L/min) demonstrated loss of signal intensity throughout the tapering zone of spatial acceleration and a small zone of more marked signal loss immediately proximal to the second orifice (always

AB - To study the effects of flow acceleration and high-velocity jets on the display characteristics of cine magnetic resonance imaging compared with color Doppler flow mapping, a custom-designed in vitro flow model was developed. This model consisted of a funnel segment tapering to an orifice (0.78 cm2) that leads into a confined receiving chamber with a second, discrete orifice (0.78 cm2) at its distal end. Cine magnetic resonance images obtained at varying flow rates (1.5 to 27.2 L/min) demonstrated loss of signal intensity throughout the tapering zone of spatial acceleration and a small zone of more marked signal loss immediately proximal to the second orifice (always

UR - http://www.scopus.com/inward/record.url?scp=0027426106&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027426106&partnerID=8YFLogxK

U2 - 10.1016/0002-8703(93)90670-5

DO - 10.1016/0002-8703(93)90670-5

M3 - Article

C2 - 8237761

AN - SCOPUS:0027426106

VL - 126

SP - 1165

EP - 1173

JO - American Heart Journal

JF - American Heart Journal

SN - 0002-8703

IS - 5

ER -