TY - JOUR
T1 - Cine magnetic resonance imaging and color Doppler flow mapping displays of flow velocity, spatial acceleration, and jet formation
T2 - A comparative in vitro study
AU - Simpson, Iain A.
AU - Maciel, Benedito C.
AU - Moises, Valdir
AU - Shandas, Robin
AU - Elias, William
AU - Valdes-Cruz, Lilliam
AU - Hesselink, John R.
AU - Chung, Kyung J.
AU - Sahn, David J.
N1 - Funding Information:
From the Division of Pediatric Cardiology, University Diego, and Oregon Health Sciences University, Portland. Dr. Simpson was supported by a British-American Research the British Heart Foundation and American Heart Association. Received for publication Jan. 21, 1993; accepted March 5, 1993. Reprint requests: David J. Sahn, MD, Pediatric Cardiology, UHNGO, gon Health Sciences University, 3181 SW Sam Jackson Park Portland, OR 97201.
PY - 1993/11
Y1 - 1993/11
N2 - To study the effects of flow acceleration and high-velocity jets on the display characteristics of cine magnetic resonance imaging compared with color Doppler flow mapping, a custom-designed in vitro flow model was developed. This model consisted of a funnel segment tapering to an orifice (0.78 cm2) that leads into a confined receiving chamber with a second, discrete orifice (0.78 cm2) at its distal end. Cine magnetic resonance images obtained at varying flow rates (1.5 to 27.2 L/min) demonstrated loss of signal intensity throughout the tapering zone of spatial acceleration and a small zone of more marked signal loss immediately proximal to the second orifice (always <50% of the signal intensity within the tapering funnel zone) associated with more rapid spatial acceleration. A formed jet was imaged distal to the first orifice, and the turbulence area surrounding the laminar central jet core correlated well with flow rate (r = 0.98), as did the distance from the orifice to the subsequent onset of flow relaminarization (r = 0.96). A turbulent spray area was always seen distal to the second, discrete orifice. Comparative observations with color Doppler flow mapping and continuous wave Doppler demonstrated that signal intensity on cine magnetic resonance imaging is reduced by both spatial acceleration, and the high-velocity and turbulent jets associated with obstructive and regurgitant lesions. In vitro evaluation of cine magnetic resonance imaging allows comparative observations to be made about the flow characteristics of cine magnetic resonance imaging and color Doppler flow mapping and provides a more rational basis for the interpretation of cine magnetic resonance imaging in the clinical setting.
AB - To study the effects of flow acceleration and high-velocity jets on the display characteristics of cine magnetic resonance imaging compared with color Doppler flow mapping, a custom-designed in vitro flow model was developed. This model consisted of a funnel segment tapering to an orifice (0.78 cm2) that leads into a confined receiving chamber with a second, discrete orifice (0.78 cm2) at its distal end. Cine magnetic resonance images obtained at varying flow rates (1.5 to 27.2 L/min) demonstrated loss of signal intensity throughout the tapering zone of spatial acceleration and a small zone of more marked signal loss immediately proximal to the second orifice (always <50% of the signal intensity within the tapering funnel zone) associated with more rapid spatial acceleration. A formed jet was imaged distal to the first orifice, and the turbulence area surrounding the laminar central jet core correlated well with flow rate (r = 0.98), as did the distance from the orifice to the subsequent onset of flow relaminarization (r = 0.96). A turbulent spray area was always seen distal to the second, discrete orifice. Comparative observations with color Doppler flow mapping and continuous wave Doppler demonstrated that signal intensity on cine magnetic resonance imaging is reduced by both spatial acceleration, and the high-velocity and turbulent jets associated with obstructive and regurgitant lesions. In vitro evaluation of cine magnetic resonance imaging allows comparative observations to be made about the flow characteristics of cine magnetic resonance imaging and color Doppler flow mapping and provides a more rational basis for the interpretation of cine magnetic resonance imaging in the clinical setting.
UR - http://www.scopus.com/inward/record.url?scp=0027426106&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0027426106&partnerID=8YFLogxK
U2 - 10.1016/0002-8703(93)90670-5
DO - 10.1016/0002-8703(93)90670-5
M3 - Article
C2 - 8237761
AN - SCOPUS:0027426106
SN - 0002-8703
VL - 126
SP - 1165
EP - 1173
JO - American Heart Journal
JF - American Heart Journal
IS - 5
ER -