Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT

Comparison to IVUS

Karsten Pohle, Stephan Achenbach, Briain MacNeill, Dieter Ropers, Maros Ferencik, Fabian Moselewski, Udo Hoffmann, Thomas J. Brady, Ik kyung Jang, Werner G. Daniel

Research output: Contribution to journalArticle

227 Citations (Scopus)

Abstract

Multi-detector row Computed Tomography (MDCT) permits non-invasive visualization of the coronary arteries. The ability to visualize and, with limitations, to characterize non-calcified coronary atherosclerotic plaque has been described. We investigated the CT attenuation of non-calcified plaques as determined by 16-slice MDCT in comparison to intravascular ultrasound (IVUS). Methods and results: Thirty-two patients were investigated by contrast-enhanced 16-slice CT. In addition, IVUS of one coronary artery (motorized pullback) was performed (LM+LAD: 22, LM+LCX: 4, RCA: 6). At 252 sites within the coronary system, in which non-calcified atherosclerotic plaque could be identified both in MDCT and IVUS, the CT attenuation within the plaque was measured using a centrally placed region of interest and correlated to the appearance of the plaque in IVUS at the corresponding location. The mean CT attenuation within plaque that corresponded to hyper-echogenic appearance in IVUS was 121 ± 34 HU (n = 76). The mean CT attenuation within plaque that corresponded to hypo-echogenic appearance was 58 ± 43 HU (n = 176, p <0.001). However, there was substantial overlap of the density values measured by MDCT in the two groups. Conclusions: A significant difference of the mean CT attenuation within atherosclerotic lesions of hypo-echogenic and hyper-echogenic appearance in IVUS could be observed. However, we observed substantial overlap of attenuation values between plaque types so that the differentiation of "vulnerable" and "stable" plaques based on their CT attenuation is doubtful.

Original languageEnglish (US)
Pages (from-to)174-180
Number of pages7
JournalAtherosclerosis
Volume190
Issue number1
DOIs
StatePublished - Jan 2007
Externally publishedYes

Fingerprint

Atherosclerotic Plaques
Tomography
Coronary Vessels

Keywords

  • Atherosclerosis
  • Computed tomography
  • Imaging
  • Plaque

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT : Comparison to IVUS. / Pohle, Karsten; Achenbach, Stephan; MacNeill, Briain; Ropers, Dieter; Ferencik, Maros; Moselewski, Fabian; Hoffmann, Udo; Brady, Thomas J.; Jang, Ik kyung; Daniel, Werner G.

In: Atherosclerosis, Vol. 190, No. 1, 01.2007, p. 174-180.

Research output: Contribution to journalArticle

Pohle, K, Achenbach, S, MacNeill, B, Ropers, D, Ferencik, M, Moselewski, F, Hoffmann, U, Brady, TJ, Jang, IK & Daniel, WG 2007, 'Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT: Comparison to IVUS', Atherosclerosis, vol. 190, no. 1, pp. 174-180. https://doi.org/10.1016/j.atherosclerosis.2006.01.013
Pohle, Karsten ; Achenbach, Stephan ; MacNeill, Briain ; Ropers, Dieter ; Ferencik, Maros ; Moselewski, Fabian ; Hoffmann, Udo ; Brady, Thomas J. ; Jang, Ik kyung ; Daniel, Werner G. / Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT : Comparison to IVUS. In: Atherosclerosis. 2007 ; Vol. 190, No. 1. pp. 174-180.
@article{9f2078d7e9ac40b39c7d201ce04713d4,
title = "Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT: Comparison to IVUS",
abstract = "Multi-detector row Computed Tomography (MDCT) permits non-invasive visualization of the coronary arteries. The ability to visualize and, with limitations, to characterize non-calcified coronary atherosclerotic plaque has been described. We investigated the CT attenuation of non-calcified plaques as determined by 16-slice MDCT in comparison to intravascular ultrasound (IVUS). Methods and results: Thirty-two patients were investigated by contrast-enhanced 16-slice CT. In addition, IVUS of one coronary artery (motorized pullback) was performed (LM+LAD: 22, LM+LCX: 4, RCA: 6). At 252 sites within the coronary system, in which non-calcified atherosclerotic plaque could be identified both in MDCT and IVUS, the CT attenuation within the plaque was measured using a centrally placed region of interest and correlated to the appearance of the plaque in IVUS at the corresponding location. The mean CT attenuation within plaque that corresponded to hyper-echogenic appearance in IVUS was 121 ± 34 HU (n = 76). The mean CT attenuation within plaque that corresponded to hypo-echogenic appearance was 58 ± 43 HU (n = 176, p <0.001). However, there was substantial overlap of the density values measured by MDCT in the two groups. Conclusions: A significant difference of the mean CT attenuation within atherosclerotic lesions of hypo-echogenic and hyper-echogenic appearance in IVUS could be observed. However, we observed substantial overlap of attenuation values between plaque types so that the differentiation of {"}vulnerable{"} and {"}stable{"} plaques based on their CT attenuation is doubtful.",
keywords = "Atherosclerosis, Computed tomography, Imaging, Plaque",
author = "Karsten Pohle and Stephan Achenbach and Briain MacNeill and Dieter Ropers and Maros Ferencik and Fabian Moselewski and Udo Hoffmann and Brady, {Thomas J.} and Jang, {Ik kyung} and Daniel, {Werner G.}",
year = "2007",
month = "1",
doi = "10.1016/j.atherosclerosis.2006.01.013",
language = "English (US)",
volume = "190",
pages = "174--180",
journal = "Atherosclerosis",
issn = "0021-9150",
publisher = "Elsevier Ireland Ltd",
number = "1",

}

TY - JOUR

T1 - Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT

T2 - Comparison to IVUS

AU - Pohle, Karsten

AU - Achenbach, Stephan

AU - MacNeill, Briain

AU - Ropers, Dieter

AU - Ferencik, Maros

AU - Moselewski, Fabian

AU - Hoffmann, Udo

AU - Brady, Thomas J.

AU - Jang, Ik kyung

AU - Daniel, Werner G.

PY - 2007/1

Y1 - 2007/1

N2 - Multi-detector row Computed Tomography (MDCT) permits non-invasive visualization of the coronary arteries. The ability to visualize and, with limitations, to characterize non-calcified coronary atherosclerotic plaque has been described. We investigated the CT attenuation of non-calcified plaques as determined by 16-slice MDCT in comparison to intravascular ultrasound (IVUS). Methods and results: Thirty-two patients were investigated by contrast-enhanced 16-slice CT. In addition, IVUS of one coronary artery (motorized pullback) was performed (LM+LAD: 22, LM+LCX: 4, RCA: 6). At 252 sites within the coronary system, in which non-calcified atherosclerotic plaque could be identified both in MDCT and IVUS, the CT attenuation within the plaque was measured using a centrally placed region of interest and correlated to the appearance of the plaque in IVUS at the corresponding location. The mean CT attenuation within plaque that corresponded to hyper-echogenic appearance in IVUS was 121 ± 34 HU (n = 76). The mean CT attenuation within plaque that corresponded to hypo-echogenic appearance was 58 ± 43 HU (n = 176, p <0.001). However, there was substantial overlap of the density values measured by MDCT in the two groups. Conclusions: A significant difference of the mean CT attenuation within atherosclerotic lesions of hypo-echogenic and hyper-echogenic appearance in IVUS could be observed. However, we observed substantial overlap of attenuation values between plaque types so that the differentiation of "vulnerable" and "stable" plaques based on their CT attenuation is doubtful.

AB - Multi-detector row Computed Tomography (MDCT) permits non-invasive visualization of the coronary arteries. The ability to visualize and, with limitations, to characterize non-calcified coronary atherosclerotic plaque has been described. We investigated the CT attenuation of non-calcified plaques as determined by 16-slice MDCT in comparison to intravascular ultrasound (IVUS). Methods and results: Thirty-two patients were investigated by contrast-enhanced 16-slice CT. In addition, IVUS of one coronary artery (motorized pullback) was performed (LM+LAD: 22, LM+LCX: 4, RCA: 6). At 252 sites within the coronary system, in which non-calcified atherosclerotic plaque could be identified both in MDCT and IVUS, the CT attenuation within the plaque was measured using a centrally placed region of interest and correlated to the appearance of the plaque in IVUS at the corresponding location. The mean CT attenuation within plaque that corresponded to hyper-echogenic appearance in IVUS was 121 ± 34 HU (n = 76). The mean CT attenuation within plaque that corresponded to hypo-echogenic appearance was 58 ± 43 HU (n = 176, p <0.001). However, there was substantial overlap of the density values measured by MDCT in the two groups. Conclusions: A significant difference of the mean CT attenuation within atherosclerotic lesions of hypo-echogenic and hyper-echogenic appearance in IVUS could be observed. However, we observed substantial overlap of attenuation values between plaque types so that the differentiation of "vulnerable" and "stable" plaques based on their CT attenuation is doubtful.

KW - Atherosclerosis

KW - Computed tomography

KW - Imaging

KW - Plaque

UR - http://www.scopus.com/inward/record.url?scp=33845392672&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33845392672&partnerID=8YFLogxK

U2 - 10.1016/j.atherosclerosis.2006.01.013

DO - 10.1016/j.atherosclerosis.2006.01.013

M3 - Article

VL - 190

SP - 174

EP - 180

JO - Atherosclerosis

JF - Atherosclerosis

SN - 0021-9150

IS - 1

ER -