Automated portable analyzer for lead(II) based on sequential flow injection and nanostructured electrochemical sensors

Wassana Yantasee, Charles Timchalk, Glen E. Fryxell, Brian P. Dockendorff, Yuehe Lin

Research output: Contribution to journalArticle

29 Citations (Scopus)

Abstract

A fully automated portable analyzer for toxic metal ion detection based on a combination of a nanostructured electrochemical sensor and a sequential flow injection system has been developed in this work. The sensor was fabricated from a carbon paste electrode modified with acetamide phosphonic acid self-assembled monolayer on mesoporous silica (Ac-Phos SAMMS) which was embedded in a very small wall-jet (flow-onto) electrochemical cell. The electrode is solid-state and mercury-free. Samples and reagents were injected into the system and flowed through the electrochemical cell by a user programmable sequential flow technique which required minimal volume of samples and reagents and allowed the automation of the analyzer operation. The portable analyzer was evaluated for lead (Pb) detection due to the excellent binding affinity between Pb and the functional groups of Ac-Phos SAMMS as well as the great concern for Pb toxicity. Linear calibration curve was obtained in a low concentration range (1-25 ppb of Pb(II)). The reproducibility was excellent; the percent relative standard deviation was 2.5 for seven consecutive measurements of 10 ppb of Pb(II) solution. Excess concentrations of Ca, Ni, Co, Zn, and Mn ions in the solutions did not interfere with detection of Pb, due to the specificity and the large number of the functional groups on the electrode surface. The electrode was reliable for at least 90 measurements over 5 days. This work is an important milestone in the development of the next-generation metal ion analyzers that are portable, fully automated, and remotely controllable.

Original languageEnglish (US)
Pages (from-to)256-261
Number of pages6
JournalTalanta
Volume68
Issue number2
DOIs
StatePublished - Dec 15 2005
Externally publishedYes

Fingerprint

Electrochemical sensors
Electrodes
Injections
Electrochemical cells
Self assembled monolayers
Ions
Silicon Dioxide
Functional groups
Metal ions
Metals
Poisons
Automation
Ointments
Mercury
Calibration
Toxicity
Carbon
Lead
Sensors
phosphonic acid

Keywords

  • Automated portable analyzer
  • Nanostructured electrochemical sensors
  • Sequential flow injection

ASJC Scopus subject areas

  • Analytical Chemistry
  • Spectroscopy

Cite this

Automated portable analyzer for lead(II) based on sequential flow injection and nanostructured electrochemical sensors. / Yantasee, Wassana; Timchalk, Charles; Fryxell, Glen E.; Dockendorff, Brian P.; Lin, Yuehe.

In: Talanta, Vol. 68, No. 2, 15.12.2005, p. 256-261.

Research output: Contribution to journalArticle

Yantasee, Wassana ; Timchalk, Charles ; Fryxell, Glen E. ; Dockendorff, Brian P. ; Lin, Yuehe. / Automated portable analyzer for lead(II) based on sequential flow injection and nanostructured electrochemical sensors. In: Talanta. 2005 ; Vol. 68, No. 2. pp. 256-261.
@article{f673c6323a5146f58965cc36e4e269c0,
title = "Automated portable analyzer for lead(II) based on sequential flow injection and nanostructured electrochemical sensors",
abstract = "A fully automated portable analyzer for toxic metal ion detection based on a combination of a nanostructured electrochemical sensor and a sequential flow injection system has been developed in this work. The sensor was fabricated from a carbon paste electrode modified with acetamide phosphonic acid self-assembled monolayer on mesoporous silica (Ac-Phos SAMMS) which was embedded in a very small wall-jet (flow-onto) electrochemical cell. The electrode is solid-state and mercury-free. Samples and reagents were injected into the system and flowed through the electrochemical cell by a user programmable sequential flow technique which required minimal volume of samples and reagents and allowed the automation of the analyzer operation. The portable analyzer was evaluated for lead (Pb) detection due to the excellent binding affinity between Pb and the functional groups of Ac-Phos SAMMS as well as the great concern for Pb toxicity. Linear calibration curve was obtained in a low concentration range (1-25 ppb of Pb(II)). The reproducibility was excellent; the percent relative standard deviation was 2.5 for seven consecutive measurements of 10 ppb of Pb(II) solution. Excess concentrations of Ca, Ni, Co, Zn, and Mn ions in the solutions did not interfere with detection of Pb, due to the specificity and the large number of the functional groups on the electrode surface. The electrode was reliable for at least 90 measurements over 5 days. This work is an important milestone in the development of the next-generation metal ion analyzers that are portable, fully automated, and remotely controllable.",
keywords = "Automated portable analyzer, Nanostructured electrochemical sensors, Sequential flow injection",
author = "Wassana Yantasee and Charles Timchalk and Fryxell, {Glen E.} and Dockendorff, {Brian P.} and Yuehe Lin",
year = "2005",
month = "12",
day = "15",
doi = "10.1016/j.talanta.2005.07.013",
language = "English (US)",
volume = "68",
pages = "256--261",
journal = "Talanta",
issn = "0039-9140",
publisher = "Elsevier",
number = "2",

}

TY - JOUR

T1 - Automated portable analyzer for lead(II) based on sequential flow injection and nanostructured electrochemical sensors

AU - Yantasee, Wassana

AU - Timchalk, Charles

AU - Fryxell, Glen E.

AU - Dockendorff, Brian P.

AU - Lin, Yuehe

PY - 2005/12/15

Y1 - 2005/12/15

N2 - A fully automated portable analyzer for toxic metal ion detection based on a combination of a nanostructured electrochemical sensor and a sequential flow injection system has been developed in this work. The sensor was fabricated from a carbon paste electrode modified with acetamide phosphonic acid self-assembled monolayer on mesoporous silica (Ac-Phos SAMMS) which was embedded in a very small wall-jet (flow-onto) electrochemical cell. The electrode is solid-state and mercury-free. Samples and reagents were injected into the system and flowed through the electrochemical cell by a user programmable sequential flow technique which required minimal volume of samples and reagents and allowed the automation of the analyzer operation. The portable analyzer was evaluated for lead (Pb) detection due to the excellent binding affinity between Pb and the functional groups of Ac-Phos SAMMS as well as the great concern for Pb toxicity. Linear calibration curve was obtained in a low concentration range (1-25 ppb of Pb(II)). The reproducibility was excellent; the percent relative standard deviation was 2.5 for seven consecutive measurements of 10 ppb of Pb(II) solution. Excess concentrations of Ca, Ni, Co, Zn, and Mn ions in the solutions did not interfere with detection of Pb, due to the specificity and the large number of the functional groups on the electrode surface. The electrode was reliable for at least 90 measurements over 5 days. This work is an important milestone in the development of the next-generation metal ion analyzers that are portable, fully automated, and remotely controllable.

AB - A fully automated portable analyzer for toxic metal ion detection based on a combination of a nanostructured electrochemical sensor and a sequential flow injection system has been developed in this work. The sensor was fabricated from a carbon paste electrode modified with acetamide phosphonic acid self-assembled monolayer on mesoporous silica (Ac-Phos SAMMS) which was embedded in a very small wall-jet (flow-onto) electrochemical cell. The electrode is solid-state and mercury-free. Samples and reagents were injected into the system and flowed through the electrochemical cell by a user programmable sequential flow technique which required minimal volume of samples and reagents and allowed the automation of the analyzer operation. The portable analyzer was evaluated for lead (Pb) detection due to the excellent binding affinity between Pb and the functional groups of Ac-Phos SAMMS as well as the great concern for Pb toxicity. Linear calibration curve was obtained in a low concentration range (1-25 ppb of Pb(II)). The reproducibility was excellent; the percent relative standard deviation was 2.5 for seven consecutive measurements of 10 ppb of Pb(II) solution. Excess concentrations of Ca, Ni, Co, Zn, and Mn ions in the solutions did not interfere with detection of Pb, due to the specificity and the large number of the functional groups on the electrode surface. The electrode was reliable for at least 90 measurements over 5 days. This work is an important milestone in the development of the next-generation metal ion analyzers that are portable, fully automated, and remotely controllable.

KW - Automated portable analyzer

KW - Nanostructured electrochemical sensors

KW - Sequential flow injection

UR - http://www.scopus.com/inward/record.url?scp=27744557304&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=27744557304&partnerID=8YFLogxK

U2 - 10.1016/j.talanta.2005.07.013

DO - 10.1016/j.talanta.2005.07.013

M3 - Article

VL - 68

SP - 256

EP - 261

JO - Talanta

JF - Talanta

SN - 0039-9140

IS - 2

ER -