Acute disruption of polytetrafluoroethylene grafts adjacent to axillary anastomoses: A complication of axillofemoral grafting

Lloyd M. Taylor, Thomas C. Park, James Edwards, Richard A. Yeager, Donald McConnell, Gregory (Greg) Moneta, John M. Porter

Research output: Contribution to journalArticle

35 Citations (Scopus)

Abstract

Purpose: Acute disruption at or adjacent to axillary anastomoses of axillofemoral grafts has been sporadically reported. We have recently reported the patency and limb salvage results of a large number of axillofemoral grafts. In this report we describe a series of axillary artery-graft disruptions that occurred in these patients. Methods: Beginning in 1983, axillofemoral bypass was performed by the authors using standardized operative technique and a single prosthetic graft material (8 mm externally supported polytetrafluoroethylene). Axillary anastomoses were placed on the first portion of the artery and were performed with the arm abducted and with the graft redundant. The records and operative reports of all patients with disruption were reviewed for findings and subsequent hospital course. Results: Two hundred two axillofemoral grafts were performed from 1983 to 1993. Ten patients (5%) had axillary disruption at intervals ranging from 1 to 46 days (mean 21 days) after operation. Ischemia was the indication for operation for seven of the patients and infected aortic prostheses for three. Infection did not occur in any of the axillary wounds and was not the cause of any of the disruptions. Four disruptions occurred with arm abduction/shoulder elevation movements; three awakened patients from sleep, and one occurred while the patient was sitting quietly. For the other two patients, preceding activity was unknown. Brachial plexus deficit was present in one patient. Four of the 10 disrupted grafts were also acutely occluded. Operative findings included sutures pulling out of the artery in four cases, tearing or sutures pulling out of the graft in four cases, and cause unknown in two cases. Treatment included arterial ligation in one patient, and restoration of circulation through revision of the axillofemoral grafts in the other nine patients. There were no operative deaths. One patient had a prolonged hospital course followed by nursing home placement and died 9 months later. The brachial plexus deficit did not resolve. There have been no repeat disruptions. Conclusions: We conclude that axillofemoral grafting includes the potential for disruption of the proximal anastomosis, which has occurred in 5% of our patients. Although multiple steps have been recommended to avoid this complication, occasional cases continue to occur despite observing all precautions.

Original languageEnglish (US)
Pages (from-to)520-528
Number of pages9
JournalJournal of Vascular Surgery
Volume20
Issue number4
DOIs
StatePublished - 1994

Fingerprint

Polytetrafluoroethylene
Transplants
Brachial Plexus
Sutures
Arm
Arteries
Axillary Artery
Limb Salvage
Nursing Homes
Prostheses and Implants
Ligation
Sleep
Ischemia

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Surgery

Cite this

Acute disruption of polytetrafluoroethylene grafts adjacent to axillary anastomoses : A complication of axillofemoral grafting. / Taylor, Lloyd M.; Park, Thomas C.; Edwards, James; Yeager, Richard A.; McConnell, Donald; Moneta, Gregory (Greg); Porter, John M.

In: Journal of Vascular Surgery, Vol. 20, No. 4, 1994, p. 520-528.

Research output: Contribution to journalArticle

Taylor, Lloyd M. ; Park, Thomas C. ; Edwards, James ; Yeager, Richard A. ; McConnell, Donald ; Moneta, Gregory (Greg) ; Porter, John M. / Acute disruption of polytetrafluoroethylene grafts adjacent to axillary anastomoses : A complication of axillofemoral grafting. In: Journal of Vascular Surgery. 1994 ; Vol. 20, No. 4. pp. 520-528.
@article{0388d9bd068a407b86c9c54d59079bb9,
title = "Acute disruption of polytetrafluoroethylene grafts adjacent to axillary anastomoses: A complication of axillofemoral grafting",
abstract = "Purpose: Acute disruption at or adjacent to axillary anastomoses of axillofemoral grafts has been sporadically reported. We have recently reported the patency and limb salvage results of a large number of axillofemoral grafts. In this report we describe a series of axillary artery-graft disruptions that occurred in these patients. Methods: Beginning in 1983, axillofemoral bypass was performed by the authors using standardized operative technique and a single prosthetic graft material (8 mm externally supported polytetrafluoroethylene). Axillary anastomoses were placed on the first portion of the artery and were performed with the arm abducted and with the graft redundant. The records and operative reports of all patients with disruption were reviewed for findings and subsequent hospital course. Results: Two hundred two axillofemoral grafts were performed from 1983 to 1993. Ten patients (5{\%}) had axillary disruption at intervals ranging from 1 to 46 days (mean 21 days) after operation. Ischemia was the indication for operation for seven of the patients and infected aortic prostheses for three. Infection did not occur in any of the axillary wounds and was not the cause of any of the disruptions. Four disruptions occurred with arm abduction/shoulder elevation movements; three awakened patients from sleep, and one occurred while the patient was sitting quietly. For the other two patients, preceding activity was unknown. Brachial plexus deficit was present in one patient. Four of the 10 disrupted grafts were also acutely occluded. Operative findings included sutures pulling out of the artery in four cases, tearing or sutures pulling out of the graft in four cases, and cause unknown in two cases. Treatment included arterial ligation in one patient, and restoration of circulation through revision of the axillofemoral grafts in the other nine patients. There were no operative deaths. One patient had a prolonged hospital course followed by nursing home placement and died 9 months later. The brachial plexus deficit did not resolve. There have been no repeat disruptions. Conclusions: We conclude that axillofemoral grafting includes the potential for disruption of the proximal anastomosis, which has occurred in 5{\%} of our patients. Although multiple steps have been recommended to avoid this complication, occasional cases continue to occur despite observing all precautions.",
author = "Taylor, {Lloyd M.} and Park, {Thomas C.} and James Edwards and Yeager, {Richard A.} and Donald McConnell and Moneta, {Gregory (Greg)} and Porter, {John M.}",
year = "1994",
doi = "10.1016/0741-5214(94)90276-3",
language = "English (US)",
volume = "20",
pages = "520--528",
journal = "Journal of Vascular Surgery",
issn = "0741-5214",
publisher = "Mosby Inc.",
number = "4",

}

TY - JOUR

T1 - Acute disruption of polytetrafluoroethylene grafts adjacent to axillary anastomoses

T2 - A complication of axillofemoral grafting

AU - Taylor, Lloyd M.

AU - Park, Thomas C.

AU - Edwards, James

AU - Yeager, Richard A.

AU - McConnell, Donald

AU - Moneta, Gregory (Greg)

AU - Porter, John M.

PY - 1994

Y1 - 1994

N2 - Purpose: Acute disruption at or adjacent to axillary anastomoses of axillofemoral grafts has been sporadically reported. We have recently reported the patency and limb salvage results of a large number of axillofemoral grafts. In this report we describe a series of axillary artery-graft disruptions that occurred in these patients. Methods: Beginning in 1983, axillofemoral bypass was performed by the authors using standardized operative technique and a single prosthetic graft material (8 mm externally supported polytetrafluoroethylene). Axillary anastomoses were placed on the first portion of the artery and were performed with the arm abducted and with the graft redundant. The records and operative reports of all patients with disruption were reviewed for findings and subsequent hospital course. Results: Two hundred two axillofemoral grafts were performed from 1983 to 1993. Ten patients (5%) had axillary disruption at intervals ranging from 1 to 46 days (mean 21 days) after operation. Ischemia was the indication for operation for seven of the patients and infected aortic prostheses for three. Infection did not occur in any of the axillary wounds and was not the cause of any of the disruptions. Four disruptions occurred with arm abduction/shoulder elevation movements; three awakened patients from sleep, and one occurred while the patient was sitting quietly. For the other two patients, preceding activity was unknown. Brachial plexus deficit was present in one patient. Four of the 10 disrupted grafts were also acutely occluded. Operative findings included sutures pulling out of the artery in four cases, tearing or sutures pulling out of the graft in four cases, and cause unknown in two cases. Treatment included arterial ligation in one patient, and restoration of circulation through revision of the axillofemoral grafts in the other nine patients. There were no operative deaths. One patient had a prolonged hospital course followed by nursing home placement and died 9 months later. The brachial plexus deficit did not resolve. There have been no repeat disruptions. Conclusions: We conclude that axillofemoral grafting includes the potential for disruption of the proximal anastomosis, which has occurred in 5% of our patients. Although multiple steps have been recommended to avoid this complication, occasional cases continue to occur despite observing all precautions.

AB - Purpose: Acute disruption at or adjacent to axillary anastomoses of axillofemoral grafts has been sporadically reported. We have recently reported the patency and limb salvage results of a large number of axillofemoral grafts. In this report we describe a series of axillary artery-graft disruptions that occurred in these patients. Methods: Beginning in 1983, axillofemoral bypass was performed by the authors using standardized operative technique and a single prosthetic graft material (8 mm externally supported polytetrafluoroethylene). Axillary anastomoses were placed on the first portion of the artery and were performed with the arm abducted and with the graft redundant. The records and operative reports of all patients with disruption were reviewed for findings and subsequent hospital course. Results: Two hundred two axillofemoral grafts were performed from 1983 to 1993. Ten patients (5%) had axillary disruption at intervals ranging from 1 to 46 days (mean 21 days) after operation. Ischemia was the indication for operation for seven of the patients and infected aortic prostheses for three. Infection did not occur in any of the axillary wounds and was not the cause of any of the disruptions. Four disruptions occurred with arm abduction/shoulder elevation movements; three awakened patients from sleep, and one occurred while the patient was sitting quietly. For the other two patients, preceding activity was unknown. Brachial plexus deficit was present in one patient. Four of the 10 disrupted grafts were also acutely occluded. Operative findings included sutures pulling out of the artery in four cases, tearing or sutures pulling out of the graft in four cases, and cause unknown in two cases. Treatment included arterial ligation in one patient, and restoration of circulation through revision of the axillofemoral grafts in the other nine patients. There were no operative deaths. One patient had a prolonged hospital course followed by nursing home placement and died 9 months later. The brachial plexus deficit did not resolve. There have been no repeat disruptions. Conclusions: We conclude that axillofemoral grafting includes the potential for disruption of the proximal anastomosis, which has occurred in 5% of our patients. Although multiple steps have been recommended to avoid this complication, occasional cases continue to occur despite observing all precautions.

UR - http://www.scopus.com/inward/record.url?scp=0028148551&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028148551&partnerID=8YFLogxK

U2 - 10.1016/0741-5214(94)90276-3

DO - 10.1016/0741-5214(94)90276-3

M3 - Article

C2 - 7933253

AN - SCOPUS:0028148551

VL - 20

SP - 520

EP - 528

JO - Journal of Vascular Surgery

JF - Journal of Vascular Surgery

SN - 0741-5214

IS - 4